Correlation and support vector machine based motion artifacts mitigation in 3D computer tomography.

Head motion during Computer Tomographic (CT) studies can adversely affects the reconstructed image through distortion and other artifacts such as blurring and doubling, thereby contributing to misdiagnosis of diseases. In this paper, we propose a method to detect and mitigate motion artifacts in three-dimensional (3D) cone-beam CT system. Motion detection is achieved by comparing the correlation coefficient between the adjacent x-ray projections. Artifacts, caused by motion, are mitigated either by replacing motion corrupted projections with their counterpart 180° apart projections under certain conditions, or by estimating motion corrupted projections using Least Square Support Vector Machine (LS-SVM) based time series prediction. The method has been evaluated on 3D Shepp-Logan phantom. In this research, Feldkamp-David-Kress (FDK) based back-projection algorithm is used for 3D reconstruction process. Computer simulation validates the motion detection and artifacts elimination mechanism.

[1]  Reza R. Adhami,et al.  An innovative approach to reduce streaking artifacts in FDK based 3D cone-beam tomography , 2011, 2011 Proceedings of IEEE Southeastcon.

[2]  Yun Zhang,et al.  Model and Simulation for Three-dimensional Medical Image Reconstruction of Spiral CT , 2008, 2008 International Conference on BioMedical Engineering and Informatics.

[3]  S. Deans The Radon Transform and Some of Its Applications , 1983 .

[4]  Jeffrey H. Siewerdsen,et al.  SU-FF-I-16: OSCaR: An Open-Source Cone-Beam CT Reconstruction Tool for Imaging Research , 2007 .

[5]  Weiguo Lu,et al.  Tomographic motion detection and correction directly in sinogram space. , 2002, Physics in medicine and biology.

[6]  Thorsten M. Buzug,et al.  Sinogram-Based Motion Detection in Transmission Computed Tomography , 2009 .

[7]  A. Rahmim,et al.  A Linogram/Sinogram Cross-Correlation Method for Motion Correction in Planar and SPECT Imaging , 2007, IEEE Transactions on Nuclear Science.

[8]  Ge Wang,et al.  X-ray transform and 3D Radon transform for ellipsoids and tetrahedra , 2004 .

[9]  Margaret E. Daube-Witherspoon,et al.  A head motion measurement system suitable for emission computed tomography , 1997, IEEE Transactions on Medical Imaging.

[10]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[11]  Liang Li,et al.  A curve-filtered FDK (C-FDK) reconstruction algorithm for circular cone-beam CT. , 2011, Journal of X-ray science and technology.

[13]  Stefan Eberl,et al.  A practical 3D tomographic method for correcting patient head motion in clinical SPECT , 1998 .

[14]  Nesreen Alsbou,et al.  An algorithm to extract three‐dimensional motion by marker tracking in the kV projections from an on‐board imager: four‐dimensional cone‐beam CT and tumor tracking implications , 2011, Journal of applied clinical medical physics.