Articulated Arm Coordinate Measuring Machine Calibration by Laser Tracker Multilateration

A new procedure for the calibration of an articulated arm coordinate measuring machine (AACMM) is presented in this paper. First, a self-calibration algorithm of four laser trackers (LTs) is developed. The spatial localization of a retroreflector target, placed in different positions within the workspace, is determined by means of a geometric multilateration system constructed from the four LTs. Next, a nonlinear optimization algorithm for the identification procedure of the AACMM is explained. An objective function based on Euclidean distances and standard deviations is developed. This function is obtained from the captured nominal data (given by the LTs used as a gauge instrument) and the data obtained by the AACMM and compares the measured and calculated coordinates of the target to obtain the identified model parameters that minimize this difference. Finally, results show that the procedure presented, using the measurements of the LTs as a gauge instrument, is very effective by improving the AACMM precision.

[1]  Tatsuo Arai,et al.  Design and accuracy evaluation of high-speed and high precision parallel mechanism , 1998, Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146).

[2]  Hiroyuki Hamana,et al.  Calibration of Articulated Arm Coordinate Measuring Machine Considering Measuring Posture , 2011, Int. J. Autom. Technol..

[3]  Qiang Gao,et al.  Multiobjective Optimization Design of a Fractional Order PID Controller for a Gun Control System , 2013, TheScientificWorldJournal.

[4]  Whee Kuk Kim,et al.  Closed-Form Forward-Position Solution for a 6-Dof 3-PPSP Parallel Mechanism and Its Implementation , 2001, Int. J. Robotics Res..

[5]  Jigien Chen,et al.  Positioning error analysis for robot manipulators with all rotary joints , 1986, IEEE Journal on Robotics and Automation.

[6]  Seung-Woo Kim,et al.  Volumetric phase-measuring interferometer for three-dimensional coordinate metrology , 2003 .

[7]  Jorge Santolaria,et al.  Identification strategy of error parameter in volumetric error compensation of machine tool based on laser tracker measurements , 2012 .

[8]  Louis J. Everett,et al.  A study of kinematic models for forward calibration of manipulators , 1988, Proceedings. 1988 IEEE International Conference on Robotics and Automation.

[9]  Igor Kovac,et al.  Testing and calibration of coordinate measuring arms , 2001 .

[10]  Jorge Santolaria,et al.  Kinematic parameter estimation technique for calibration and repeatability improvement of articulated arm coordinate measuring machines , 2008 .

[11]  Adam Gąska,et al.  Modeling and identification of errors of coordinate measuring arms with the use of a metrological model , 2013 .

[12]  Rosenda Valdés Arencibia,et al.  Application of Virtual Spheres Plate for AACMMs evaluation , 2012 .

[13]  J. Denavit,et al.  A kinematic notation for lower pair mechanisms based on matrices , 1955 .

[14]  Arthur C. Sanderson,et al.  Arm signature identification , 1986, Proceedings. 1986 IEEE International Conference on Robotics and Automation.

[15]  Antonio Piratelli-Filho,et al.  Virtual spheres gauge for coordinate measuring arms performance test , 2010 .

[16]  Yonggang Hu,et al.  Research on optimal measurement area of flexible coordinate measuring machines , 2012 .

[17]  L. J. Everett,et al.  IDENTIFICATION OF THE KINEMATIC PARAMETERS OF A ROBOT MANIPULATOR FOR POSITIONAL ACCURACY IMPROVEMENT. , 1985 .

[18]  T. Kurosawa,et al.  The relationship between the measurement error and the arrangement of laser trackers in laser trilateration , 2000 .

[19]  G. N. Peggs,et al.  Design of a High-Accuracy CMM Based on Multi-Lateration Techniques , 2000 .

[20]  J. J. Aguilar,et al.  Influence of measurement noise and laser arrangement on measurement uncertainty of laser tracker multilateration in machine tool volumetric verification , 2013 .

[21]  Kenneth Levenberg A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .

[22]  Fiorenzo Franceschini,et al.  Experimental comparison of dynamic tracking performance of iGPS and laser tracker , 2011 .

[23]  Jorge Santolaria,et al.  A self-centering active probing technique for kinematic parameter identification and verification of articulated arm coordinate measuring machines , 2010 .

[24]  Chien-Chang Lin,et al.  Calibrating the volumetric errors of a precision machine by a laser tracker system , 2005 .

[25]  Kiyoshi Takamasu,et al.  The estimation method of uncertainty of articulated coordinate measuring machine , 2002, 2002 IEEE International Conference on Industrial Technology, 2002. IEEE ICIT '02..

[26]  P. Maropoulos,et al.  Modelling and optimization of novel laser multilateration schemes for high-precision applications , 2005 .

[27]  Yann Nguyen,et al.  Design, Kinematic Optimization, and Evaluation of a Teleoperated System for Middle Ear Microsurgery , 2012, TheScientificWorldJournal.

[28]  Jerzy Sładek,et al.  KINEMATIC METROLOGICAL MODEL OF THE COORDINATE MEASURING ARM (MCMA) , 2009 .

[29]  Jorge Santolaria,et al.  An Overview of Kinematic and Calibration Models Using Internal/External Sensors or Constraints to Improve the Behavior of Spatial Parallel Mechanisms , 2010, Sensors.