A Fault Location Technique for Two-Terminal Multisection Compound Transmission Lines Using Synchronized Phasor Measurements

This paper presents a fault location technique for two-terminal multisection compound transmission lines, which combine overhead lines with underground power cables, using synchronized phasor measurements acquired by global positioning system (GPS) based phasor measurement units (PMUs) or digital relays with embedded PMU or by fault-on relay data synchronization algorithms. The technique is extended from a two-terminal fault location method with synchronized phasor measurements as inputs. A novel fault section selector is proposed to select the fault line section in advance. The proposed technique has the ability to locate a fault no matter where the fault is on overhead line or underground power cable. The adopted technique has a solid theoretical foundation and is direct and simple in terms of computational complexity. Both extensive simulation results and field test results are presented to demonstrate the effectiveness of the proposed scheme. The proposed technique has already been implemented in the Taiwan power system since the year 2008. Up to the present, the proposed technique yields excellent performance in practice.

[1]  K. Uemura,et al.  A New Alogorithm of an Accurate Fault Location for EHV/UHV Transmission Lines: Part I - Fourier Transformation Method , 1981, IEEE Transactions on Power Apparatus and Systems.

[2]  Ching-Shan Chen,et al.  A Universal Fault Location Technique for N-Terminal $({N}\geqq 3)$ Transmission Lines , 2008, IEEE Transactions on Power Delivery.

[3]  G. Benmouyal,et al.  Removal of DC-offset in current waveforms using digital mimic filtering , 1995 .

[4]  M.M. Abdel Aziz,et al.  An accurate scheme for fault location in combined overhead line with underground power cable , 2005, IEEE Power Engineering Society General Meeting, 2005.

[5]  Ying-Hong Lin,et al.  A new PMU-based fault detection/location technique for transmission lines with consideration of arcing fault discrimination-part I: theory and algorithms , 2004 .

[6]  Chih-Wen Liu,et al.  Closure on "A new protection scheme for fault detection, direction discrimination, classification, and location in transmission lines" , 2003 .

[7]  Damir Novosel,et al.  Fault location using digital relay data , 1995 .

[8]  Charles Arthur Gross Power System Analysis , 1979 .

[9]  Chi-Shan Yu,et al.  A New PMU-Based Fault Location Algorithm for Series Compensated Lines , 2001, IEEE Power Engineering Review.

[10]  H.H. Zurn,et al.  An Iterative Two-Terminal Fault-Location Method Based on Unsynchronized Phasors , 2008, IEEE Transactions on Power Delivery.

[11]  Yuan Liao,et al.  Optimal Estimate of Transmission Line Fault Location Considering Measurement Errors , 2007, IEEE Transactions on Power Delivery.

[12]  Seung-Jae Lee,et al.  Fault Location for Underground Power Cable Using Distributed Parameter Approach , 2008, IEEE Transactions on Power Systems.

[13]  Ying-Hong Lin,et al.  A new PMU-based fault detection/location technique for transmission lines with consideration of arcing fault discrimination-part II: performance evaluation , 2004 .

[14]  J.-A. Jiang,et al.  Application of combined adaptive Fourier filtering technique and fault detector to fast distance protection , 2006, IEEE Transactions on Power Delivery.

[15]  Jacqueline Grennon , 2nd Ed. , 2002, The Journal of nervous and mental disease.

[16]  Chi-Shan Yu An Unsynchronized Measurements Correction Method for Two-Terminal Fault-Location Problems , 2010, IEEE Transactions on Power Delivery.

[17]  S.M. Brahma,et al.  Fault location scheme for a multi-terminal transmission line using synchronized Voltage measurements , 2005, IEEE Transactions on Power Delivery.

[18]  C. W. Liu,et al.  A New Fault Locator for Three-Terminal Transmission Lines Using Two Terminal Synchronized Voltage and Current Phasors , 2001, IEEE Power Engineering Review.

[19]  Arun G. Phadke,et al.  Synchronized Phasor Measurements and Their Applications , 2008 .

[20]  Mladen Kezunovic,et al.  Automated transmission line fault analysis using synchronized sampling at two ends , 1995 .

[21]  C.J. Lee,et al.  A new two-terminal numerical algorithm for fault location, distance protection, and arcing fault recognition , 2006, IEEE Transactions on Power Systems.

[22]  Adly A. Girgis,et al.  A new fault location technique for two- and three-terminal lines , 1992 .

[23]  Mladen Kezunovic,et al.  An accurate fault location algorithm using synchronized sampling , 1994 .

[24]  N.I. Elkalashy,et al.  Modeling and experimental verification of high impedance arcing fault in medium voltage networks , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[25]  J. A. Jiang,et al.  A New Adaptive PMU-Based Protection Scheme for Transposed/Untransposed Parallel Transmission Lines , 2002, IEEE Power Engineering Review.

[26]  T. Takagi,et al.  Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data , 1982, IEEE Power Engineering Review.