Investigation on the effect of innovative cool tiles on local indoor thermal conditions: Finite element modeling and continuous monitoring

The achievement of building indoor thermal comfort conditions with the minimum energy need represents a challenge for both designers and researchers. To this aim, the development of passive strategies, e.g. cool roofs, for reducing the thermal gain entering building envelopes has spread in the scientific community. In this view, Computational Fluid Dynamic method is applied in this research in order to quantify the effect of a cool roof solution within the indoor environment of the thermal zone adjacent to the roof, by analyzing the attic local conditions. The case study is represented by an attic room of a continuously monitored residential building located in central Italy. A two-dimensional finite element analysis is carried out to investigate the indoor air temperature and air velocity field inside the attic. The available experimental data are used for validation. Therefore, the thermal profiles generated by (i) the roof with traditional brown-colored brick tiles and (ii) the same roof with innovative cool clay tiles are investigated. The final purpose is to compare the indoor thermal comfort conditions generated within the vertical cross section of the attic, in order to study the cool roof effect at different height of occupants' body. The main results show up to 2.79 K and 1.54 K air temperature difference between the cool and traditional roof configurations, in summer and winter conditions, respectively. A thermal stratification is detected during summer inside the attic, leading to strongly non homogeneous comfort conditions, particularly marked in the “hot” tiles scenario, demonstrating the usefulness of this contribution.

[1]  Poh-Chin Lai,et al.  The impact of environmental and human factors on urban heat and microclimate variability , 2016 .

[2]  M. Santamouris Cooling the cities – A review of reflective and green roof mitigation technologies to fight heat island and improve comfort in urban environments , 2014 .

[3]  Ferdinando Salata,et al.  How high albedo and traditional buildings’ materials and vegetation affect the quality of urban microclimate. A case study , 2015 .

[4]  L. Namli,et al.  Laminar natural convection in a pitched roof of triangular cross-section: summer day boundary conditions , 2000 .

[5]  Shafqat Hussain,et al.  Numerical investigations of buoyancy-driven natural ventilation in a simple atrium building and its effect on the thermal comfort conditions , 2012 .

[6]  Manuel Gameiro da Silva,et al.  Assessment of indoor air quality and thermal comfort in Portuguese secondary classrooms: Methodology and results , 2014 .

[7]  M. Santamouris,et al.  Green and cool roofs’ urban heat island mitigation potential in European climates for office buildings under free floating conditions , 2013 .

[8]  Hashem Akbari,et al.  Measured energy savings from the application of reflective roofs in two small non-residential buildings , 2003 .

[9]  Shafqat Hussain,et al.  Numerical investigations of buoyancy-driven natural ventilation in a simple three-storey atrium building and thermal comfort evaluation , 2013 .

[10]  Hashem Akbari,et al.  Peak power and cooling energy savings of high-albedo roofs , 1997 .

[11]  H. Akbari,et al.  Heating energy penalties of cool roofs: the effect of snow accumulation on roofs , 2014 .

[12]  Li Yang,et al.  CFD simulation research on residential indoor air quality. , 2014, The Science of the total environment.

[13]  Matheos Santamouris,et al.  Studying the effect of “cool” coatings in street urban canyons and its potential as a heat island mitigation technique , 2014 .

[14]  Andy van den Dobbelsteen,et al.  Building microclimate and summer thermal comfort in free-running buildings with diverse spaces: A Chinese vernacular house case , 2014 .

[15]  Tassos G. Karayiannis,et al.  Flow field and Reynolds stress distribution in low turbulance natural convection in a triangular cavity , 2006 .

[16]  Hashem Akbari,et al.  Energy savings potentials of commercial buildings by urban heat island reduction strategies in Montreal (Canada) , 2016 .

[17]  Antonio Campo,et al.  Numerical computation of buoyant airflows confined to attic spaces under opposing hot and cold wall conditions , 2005 .

[18]  H. Akbari,et al.  Estimating the effect of using cool coatings on energy loads and thermal comfort in residential buildings in various climatic conditions , 2007 .

[19]  Yoshihide Tominaga,et al.  Air flow around isolated gable-roof buildings with different roof pitches: Wind tunnel experiments and CFD simulations , 2015 .

[20]  Anna Laura Pisello,et al.  The thermal effect of an innovative cool roof on residential buildings in Italy: Results from two years of continuous monitoring , 2014 .

[21]  van Taj Twan Hooff,et al.  Reprint of: On the predicted effectiveness of climate adaptation measures for residential buildings , 2015 .

[22]  A. R. Balakrishnan,et al.  Finite element analysis of natural convection flow in a isosceles triangular enclosure due to uniform and non-uniform heating at the side walls , 2008 .

[23]  Suvash C. Saha,et al.  Natural convection and heat transfer in attics subject to periodic thermal forcing , 2010 .

[24]  Gianpiero Colangelo,et al.  CFD simulations of horizontal ground heat exchangers: A comparison among different configurations , 2012 .

[25]  Antonio Campo,et al.  Turbulent natural convection in an air-filled isosceles triangular enclosure , 2006 .

[26]  C. Gorlé,et al.  Quantifying inflow uncertainties for CFD simulations of the flow in downtown Oklahoma City , 2014 .

[27]  Dereje Agonafer,et al.  LVEL turbulence model for conjugate heat transfer at low Reynolds numbers , 1996 .

[28]  Y. Tominaga Flow around a high-rise building using steady and unsteady RANS CFD: Effect of large-scale fluctuations on the velocity statistics , 2015 .

[29]  Mohammad Heidarinejad,et al.  Effect of urban neighborhoods on the performance of building cooling systems , 2015 .

[30]  Luisa F. Cabeza,et al.  A correlation of the convective heat transfer coefficient between an air flow and a phase change material plate , 2013 .

[31]  Michael W. Collins,et al.  A Comprehensive Review of Natural Convection in Triangular Enclosures , 2010 .

[32]  Bje Bert Blocken,et al.  Review of external convective heat transfer coefficient models in building energy simulation programs: implementation and uncertainty , 2013 .

[33]  Hashem Akbari,et al.  Effect of cool roofs on commercial buildings energy use in cold climates , 2016 .

[34]  João A. Labrincha,et al.  Eco-efficient Construction and Building Materials , 2011 .

[35]  Niki Gaitani,et al.  Experimental testing of cool colored thin layer asphalt and estimation of its potential to improve the urban microclimate , 2011 .

[36]  Lars Westerlund,et al.  CFD simulation and evaluation of different heating systems installed in low energy building located in sub-arctic climate , 2015 .

[37]  Anna Laura Pisello,et al.  Experimental in-lab and in-field analysis of waterproof membranes for cool roof application and urban heat island mitigation , 2016 .