Review of convergent beam tomography in single photon emission computed tomography.

Investigation of convergent-beam single photon emission computed tomography (SPECT) is actively being pursued to evaluate its clinical potentials. Fan-beam, cone-beam, pin-hole and astigmatic collimators are being used with rotating gamma cameras having large crystal areas, to increase the sensitivity for emission and transmission computed tomography of small organs such as the thyroid, brain or heart. With new multi-detector SPECT systems, convergent-beam geometry offers the ability to simultaneously obtain emission and transmission data necessary to quantify uptake of radiopharmaceutical distributions in the heart. The development of convergent-beam geometry in SPECT requires the integration of hardware and software. In considering hardware, the optimum detector system for cone-beam tomography is a system that satisfies the data sufficiency condition for which the scanning trajectory intersects any plane passing through the reconstructed region of interest. However, the major development of algorithms has been for the data insufficient case of single planar orbit acquisitions. The development of these algorithms have made possible the preliminary evaluation of this technology and the imaging of brain and heart are showing significant potential for the clinical application of cone-beam tomography. Presently, significant research activity is pursuing the development of algorithms for data acquisitions that satisfy the data sufficiency condition and that can be implemented easily and inexpensively on clinical SPECT systems.

[1]  G T Gullberg,et al.  Single photon emission computed tomography of the heart using cone beam geometry and noncircular detector rotation. , 1991, Progress in clinical and biological research.

[2]  R. Jaszczak,et al.  Cone beam SPECT reconstruction with camera tilt. , 1989, Physics in medicine and biology.

[3]  Gengsheng Lawrence Zeng,et al.  A cone-beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography , 1992, IEEE Trans. Medical Imaging.

[4]  A. Formiconi,et al.  Compensation of spatial system response in SPECT with conjugate gradient reconstruction technique. , 1989, Physics in medicine and biology.

[5]  Ronald J. Jaszczak,et al.  Maximum likelihood reconstruction for cone beam SPECT with camera tilt , 1989 .

[6]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[7]  C. E. Floyd,et al.  Cone Beam Collimation for SPECT: Simulation and Reconstruction , 1986, IEEE Transactions on Nuclear Science.

[8]  C E Floyd,et al.  Inverse Monte Carlo as a unified reconstruction algorithm for ECT. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  Bruce D. Smith Image Reconstruction from Cone-Beam Projections: Necessary and Sufficient Conditions and Reconstruction Methods , 1985, IEEE Transactions on Medical Imaging.

[10]  R J Jaszczak,et al.  SPECT using a specially designed cone beam collimator. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  S Webb,et al.  A comparison of attenuation correction methods for quantitative single photon emission computed tomography. , 1983, Physics in medicine and biology.

[12]  Benjamin M. W. Tsui,et al.  Estimation of geometrical parameters for fan beam tomography , 1987 .

[13]  D. Bailey,et al.  Improved SPECT using simultaneous emission and transmission tomography. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  F D Thomas,et al.  Attenuation compensation of cone beam SPECT images using maximum likelihood reconstruction. , 1991, IEEE transactions on medical imaging.

[15]  Gengsheng Larry Zeng,et al.  Short-scan fan beam algorithm for noncircular detector orbits , 1991, Medical Imaging.

[16]  R. Jaszczak,et al.  Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection. , 1986, Medical physics.

[17]  Gengsheng Lawrence Zeng,et al.  An iterative reconstruction algorithm for single photon emission computed tomography with cone beam geometry , 1989, Int. J. Imaging Syst. Technol..

[18]  Ronald J. Jaszczak,et al.  Comparison 180° and 360° Data Collection in Thallium-201 Imaging Using Single-Photon Emission Computerized Tomography (SPECT): Concise Communication , 1982 .

[19]  K Torizuka,et al.  Comparative study of thallium emission myocardial tomography with 180 degrees and 360 degrees data collection. , 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  G T Gullberg,et al.  Estimation of geometrical parameters and collimator evaluation for cone beam tomography. , 1990, Medical physics.

[21]  D. Gilland,et al.  Implementation of simultaneous attenuation and detector response correction in SPECT , 1988 .

[22]  Gengsheng L. Zeng,et al.  A study of reconstruction artifacts in cone beam tomography using filtered backprojection and iterative EM algorithms , 1990 .

[23]  Franklin S. Weinstein,et al.  Formation of images using fan-beam scanning and noncircular source motion , 1980 .

[24]  C E Floyd,et al.  Noise characteristics for cone beam collimators: a comparison with parallel hole collimator. , 1988, Physics in medicine and biology.

[25]  Grant T. Gullberg,et al.  Short-scan cone beam algorithm for circular and noncircular detector orbits , 1990, Medical Imaging: Image Processing.

[26]  P Wollmer,et al.  Pinhole emission computed tomography: method and experimental evaluation. , 1990, Physics in medicine and biology.

[27]  David H. Feiglin,et al.  Clinical Evaluation of 360° and 180° Data Sampling Techniques for Transaxial SPECT Thallium-201 Myocardial Perfusion Imaging , 1985 .

[28]  R. Pettigrew,et al.  Fundamentals of 180 degree acquisition and reconstruction in SPECT imaging. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[29]  C E Floyd,et al.  Maximum likelihood reconstruction for cone beam SPECT: development and initial tests. , 1989, Physics in medicine and biology.

[30]  G T Gullberg,et al.  SPECT liver imaging using an iterative attenuation correction algorithm and an external flood source. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[31]  Gengsheng Lawrence Zeng,et al.  Cone Beam Single Photon Emission Computed Tomography Using Two Orbits , 1991, IPMI.

[32]  J R Perry,et al.  Correction of nonuniform attenuation in cardiac SPECT imaging. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[33]  G T Gullberg,et al.  The geometric transfer function for cone and fan beam collimators. , 1990, Physics in medicine and biology.

[34]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[35]  R. Jaszczak,et al.  Imaging characteristics of a high resolution cone beam collimator , 1988 .

[36]  R. Jaszczak,et al.  Single Photon Emission Computed Tomography Using Multi-Slice Fan Beam Collimators , 1979 .

[37]  T. Turkington,et al.  Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions. , 1992, Physics in medicine and biology.

[38]  R W Parkey,et al.  Attenuation compensation in single-photon emission tomography: a comparative evaluation. , 1982, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[39]  G T Gullberg,et al.  Cone beam tomography of the heart using single-photon emission-computed tomography. , 1991, Investigative radiology.

[40]  S. Manglos,et al.  Attenuation maps for SPECT determined using cone beam transmission computed tomography , 1990 .

[41]  G T Gullberg,et al.  A cone-beam tomography algorithm for orthogonal circle-and-line orbit. , 1992, Physics in medicine and biology.

[42]  J. Terry,et al.  Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction , 1990 .

[43]  Bruce D. Smith Cone-beam tomography: recent advances and a tutorial review , 1990 .

[44]  D R Gilland,et al.  Design and clinical utility of a fan beam collimator for SPECT imaging of the head. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[45]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .