Helium-3 diffusion MR imaging of the human lung over multiple time scales.

RATIONALE AND OBJECTIVES Diffusion magnetic resonance imaging (MRI) with hyperpolarized (3)He gas is a powerful technique for probing the characteristics of the lung microstructure. A key parameter for this technique is the diffusion time, which is the period during which the atoms are allowed to diffuse within the lung for measurement of the signal attenuation. The relationship between diffusion time and the length scales that can be explored is discussed, and representative, preliminary results are presented from ongoing studies of the human lung for diffusion times ranging from milliseconds to several seconds. MATERIALS AND METHODS (3)He diffusion MRI of the human lung was performed on a 1.5T Siemens Sonata scanner. Using gradient echo-based and stimulated echo-based techniques for short and medium-to-long diffusion times, respectively, measurements were performed for times ranging from 2 milliseconds to 6.5 seconds in two healthy subjects, a subject with subclinical chronic obstructive pulmonary disease and a subject with bronchopulmonary dysplasia. RESULTS In healthy subjects, the apparent diffusion coefficient decreased by about 10-fold, from approximately 0.2 to 0.02 cm(2)/second, as the diffusion time increased from approximately 1 millisecond to 1 second. Results in subjects with disease suggest that measurements made at diffusion times substantially longer than 1 millisecond may provide improved sensitivity for detecting certain pathologic changes in the lung microstructure. CONCLUSIONS With appropriately designed pulse sequences it is possible to explore the diffusion of hyperpolarized (3)He in the human lung over more than a 1,000-fold variation of the diffusion time. Such measurements provide a new opportunity for exploring and characterizing the microstructure of the healthy and diseased lung.

[1]  Dmitriy A Yablonskiy,et al.  Magnetization tagging decay to measure long‐range 3He diffusion in healthy and emphysematous canine lungs , 2004, Magnetic resonance in medicine.

[2]  J. E. Tanner Use of the Stimulated Echo in NMR Diffusion Studies , 1970 .

[3]  J. Hogg,et al.  Long-range diffusion of hyperpolarized 3He in explanted normal and emphysematous human lungs via magnetization tagging. , 2005, Journal of applied physiology.

[4]  John P Mugler,et al.  Emphysema: hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes--initial experience. , 2002, Radiology.

[5]  D. Yablonskiy,et al.  MR imaging of diffusion of 3He gas in healthy and diseased lungs , 2000, Magnetic resonance in medicine.

[6]  A. Sukstanskii,et al.  3He diffusion MRI of the lung. , 2005, Academic radiology.

[7]  John P Mugler,et al.  Detection of age-dependent changes in healthy adult lungs with diffusion-weighted 3He MRI. , 2005, Academic radiology.

[8]  John P Mugler,et al.  Evaluation of asthma with hyperpolarized helium-3 MRI: correlation with clinical severity and spirometry. , 2006, Chest.

[9]  R J Traystman,et al.  Collateral ventilation in man. , 1978, The New England journal of medicine.

[10]  John P Mugler,et al.  Functional MRI of the lung using hyperpolarized 3‐helium gas , 2004, Journal of magnetic resonance imaging : JMRI.

[11]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[12]  M. Salerno,et al.  Hyperpolarized 3He lung imaging at 0.5 and 1.5 Tesla: A study of susceptibility‐induced effects , 2005, Magnetic resonance in medicine.

[13]  G. Miller,et al.  q‐space analysis of lung morphometry in vivo with hyperpolarized 3He spectroscopy , 2006, Journal of magnetic resonance imaging : JMRI.

[14]  M. Lebowitz,et al.  Changes in the normal maximal expiratory flow-volume curve with growth and aging. , 1983, The American review of respiratory disease.

[15]  Eduard E de Lange,et al.  MRI of the lungs using hyperpolarized noble gases , 2002, Magnetic resonance in medicine.

[16]  E. V. van Beek,et al.  Measurements and modeling of long range 3He diffusion in the lung using a "slice-washout" method. , 2005, Journal of magnetic resonance.

[17]  Dmitriy A Yablonskiy,et al.  Quantitative in vivo assessment of lung microstructure at the alveolar level with hyperpolarized 3He diffusion MRI , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[18]  John P Mugler,et al.  Assessment of lung development using hyperpolarized helium‐3 diffusion MR imaging , 2006, Journal of magnetic resonance imaging : JMRI.

[19]  G. Miller,et al.  Time dependence of 3He diffusion in the human lung: Measurement in the long‐time regime using stimulated echoes , 2006, Magnetic resonance in medicine.

[20]  T A Altes,et al.  Hyperpolarized 3He MR lung ventilation imaging in asthmatics: Preliminary findings , 2001, Journal of magnetic resonance imaging : JMRI.

[21]  Frank R. Korosec,et al.  Early Emphysematous Changes in Asymptomatic Smokers: Detection with 3He MR Imaging , 2006 .

[22]  Edwin J R van Beek,et al.  Investigating 3He diffusion NMR in the lungs using finite difference simulations and in vivo PGSE experiments. , 2004, Journal of magnetic resonance.