CdTe Based Energy Resolving, X-ray Photon Counting Detector Performance Assessment: The Effects of Charge Sharing Correction Algorithm Choice

Most modern energy resolving, photon counting detectors employ small (sub 1 mm) pixels for high spatial resolution and low per pixel count rate requirements. These small pixels can suffer from a range of charge sharing effects (CSEs) that degrade both spectral analysis and imaging metrics. A range of charge sharing correction algorithms (CSCAs) have been proposed and validated by different groups to reduce CSEs, however their performance is often compared solely to the same system when no such corrections are made. In this paper, a combination of Monte Carlo and finite element methods are used to compare six different CSCAs with the case where no CSCA is employed, with respect to four different metrics: absolute detection efficiency, photopeak detection efficiency, relative coincidence counts, and binned spectral efficiency. The performance of the various CSCAs is explored when running on systems with pixel pitches ranging from 100 µm to 600µm, in 50 µm increments, and fluxes from 106 to 108 photons mm−2 s−1 are considered. Novel mechanistic explanations for the difference in performance of the various CSCAs are proposed and supported. This work represents a subset of a larger project in which pixel pitch, thickness, flux, and CSCA are all varied systematically.

[1]  Stefan Ulzheimer,et al.  Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans. , 2017, Radiology.

[2]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.

[3]  Amir Pourmorteza,et al.  Photon-counting CT: Technical Principles and Clinical Prospects. , 2018, Radiology.

[4]  Thomas H. Prettyman,et al.  Method for mapping charge pulses in semiconductor radiation detectors , 1998 .

[5]  M. Campbell,et al.  The Medipix3 Prototype, a Pixel Readout Chip Working in Single Photon Counting Mode With Improved Spectrometric Performance , 2006, IEEE Transactions on Nuclear Science.

[6]  P. Delogu,et al.  Characterization of the acquisition modes implemented in Pixirad-1/Pixie-III X-ray Detector: Effects of charge sharing correction on spectral resolution and image quality , 2020 .

[7]  Krzysztof Iniewski,et al.  Characterisation of Redlen high-flux CdZnTe , 2017 .

[8]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[9]  Christer Ullberg,et al.  Measurements of a dual-energy fast photon counting CdTe detector with integrated charge sharing correction , 2013, Medical Imaging.

[10]  A. Butler,et al.  Quantitative imaging performance of MARS spectral photon-counting CT for radiotherapy. , 2020, Medical physics.

[11]  Inclusion of a Charge Sharing Correction Algorithm Into an X-Ray Photon Counting Spectral Detector Simulation Framework , 2021, IEEE Transactions on Radiation and Plasma Medical Sciences.

[12]  Uwe Oelfke,et al.  Imaging properties of small-pixel spectroscopic x-ray detectors based on cadmium telluride sensors , 2012, Physics in medicine and biology.

[13]  Scott S Hsieh Coincidence Counters for Charge Sharing Compensation in Spectroscopic Photon Counting Detectors , 2020, IEEE Transactions on Medical Imaging.

[14]  K. Taguchi Multi-energy inter-pixel coincidence counters for charge sharing correction and compensation in photon counting detectors. , 2020, Medical physics.

[15]  Jeffrey C. Bamber,et al.  The Effects of Spectral X-Ray Photon Counting Detector Parameters on Detector Performance: Thickness and Pitch , 2020, IEEE Access.

[16]  Tadayui Takahashi,et al.  Recent progress in CdTe and CdZnTe detectors , 2001, astro-ph/0107398.

[17]  D. Bale,et al.  Dynamic Lateral Polarization in CdZnTe Under High Flux X-Ray Irradiation , 2007, IEEE Transactions on Nuclear Science.

[18]  Daniel Turecek,et al.  Characterization of Medipix3 With Synchrotron Radiation , 2011, IEEE Transactions on Nuclear Science.

[19]  Paurakh L. Rajbhandary,et al.  Spectral resolution and high‐flux capability tradeoffs in CdTe detectors for clinical CT , 2018, Medical physics.

[20]  Krzysztof Iniewski,et al.  Measurements of charge sharing in small pixel CdTe detectors , 2014 .

[21]  Katsuyuki Taguchi,et al.  Estimation of Basis Line-Integrals in a Spectral Distortion-Modeled Photon Counting Detector Using Low-Order Polynomial Approximation of X-ray Transmittance , 2017, IEEE Trans. Medical Imaging.

[22]  D. Darambara,et al.  Computational modelling of pixelated CdZnTe detectors for x- and γ- ray imaging applications , 2012 .

[23]  R. Ballabriga,et al.  Photon Counting Detectors for X-Ray Imaging With Emphasis on CT , 2021, IEEE Transactions on Radiation and Plasma Medical Sciences.

[24]  P Guerra,et al.  Development of a simplified simulation model for performance characterization of a pixellated CdZnTe multimodality imaging system , 2008, Physics in medicine and biology.

[25]  P. Gryboś,et al.  Characterization of the Photon Counting CHASE Jr., Chip Built in a 40-nm CMOS Process With a Charge Sharing Correction Algorithm Using a Collimated X-Ray Beam , 2017, IEEE Transactions on Nuclear Science.

[26]  Ewald Roessl,et al.  Multicolor spectral photon-counting computed tomography: in vivo dual contrast imaging with a high count rate scanner , 2017, Scientific Reports.

[27]  C. McCollough,et al.  Multi-energy CT imaging for large patients using dual-source photon-counting detector CT , 2020, Physics in medicine and biology.

[28]  A. Butler,et al.  Spectral Photon-Counting Molecular Imaging for Quantification of Monoclonal Antibody-Conjugated Gold Nanoparticles Targeted to Lymphoma and Breast Cancer: An In Vitro Study , 2018, Contrast media & molecular imaging.

[29]  Mats Persson,et al.  Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study , 2020, Journal of medical imaging.