Cochlear Implant Failures and Revision

Objective: To review cases involving implant failure and revision surgery in a large cochlear implant program. Study Design: Retrospective case series. Setting: Cochlear implant program in an academic medical center. Patients: Adults and children who underwent revision cochlear implantation (n = 58). Intervention: Diagnosis and explantation of failed cochlear implants, with subsequent reimplantation. Assessment of implant function and speech perception. Main Outcome Measures: Device type, time from implantation to revision, cause of failure, performance with original implant versus revision, number of electrodes placed, and surgical challenges related to reimplantation. Results: Forty-five patients initially implanted at this program and 13 patients implanted elsewhere underwent revision surgery. The institutional device failure rate was 3.7% and the overall revision rate was 5.1%. Reasons for implant revision included documented internal device failure (46%), scalp flap complications (17%), optimization of electrode placement (13%), unexplained deterioration of performance (12%), technology upgrade (10%), and intratemporal pathology (3%). Revision surgery typically involved only minor anatomic challenges, but five patients required circumodiolar drillout procedures to improve electrode position. Electrode insertion was equal or deeper in 53 of 58 cases. Speech perception ability decreased in only three patients. Conclusions: Management of implant failures and performance of revision surgery are becoming increasingly important in cochlear implant programs. Outcomes are generally excellent. Revision implantation is a safe and appropriate procedure that should be pursued in a timely fashion when patients experience cochlear implant failure.

[1]  S. Waltzman,et al.  Cochlear Reimplantation: Surgical Techniques and Functional Results , 2001, The Laryngoscope.

[2]  P. Chute,et al.  Cochlear implant mechanical failures. , 1996, The American journal of otology.

[3]  M. Svirsky,et al.  Cochlear implant reimplantation. , 1997, The American journal of otology.

[4]  Surgical and Safety Considerations of Multichannel Cochlear Implants in Children , 1991, Ear and hearing.

[5]  H. El-Kashlan,et al.  Cochlear Implantation in Prelingually Deaf Children with Ossified Cochleae , 2003, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[6]  S. Mukherji,et al.  Cochlear implant failure: imaging evaluation of the electrode course. , 2003, Clinical radiology.

[7]  P. Chute,et al.  Outcome Analysis of Cochlear Implant Reimplantation in Children , 2001, The Laryngoscope.

[8]  S. Telian,et al.  Successful revision of failed cochlear implants in severe labyrinthitis ossificans. , 1996, The American journal of otology.

[9]  A. Hodges,et al.  Cochlear reimplantation , 1999, The Laryngoscope.

[10]  A. Q. Summerfield,et al.  Cochlear implantation--United Kingdom and Ireland surgical survey. , 2003, Cochlear implants international.

[11]  S A Telian,et al.  Patient performance with the Cochlear Corporation "20 + 2" implant: bipolar versus monopolar activation. , 1996, The American journal of otology.

[12]  N. Cohen,et al.  Surgical pitfalls in cochlear implantation , 1993, The Laryngoscope.

[13]  R. Shepherd,et al.  Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque. , 1995, The American journal of otology.

[14]  D. Mills,et al.  Cochlear implant performance after reimplantation: a multicenter study. , 1999, The American journal of otology.

[15]  H. El-Kashlan,et al.  Minimizing wound complications in cochlear implant surgery. , 1999, The American journal of otology.

[16]  P. Chute,et al.  Results of cochlear implant reinsertion , 1991, The Laryngoscope.