Tremor suppression through impedance control.

This paper presents a method for designing tremor suppression systems that achieve a specified reduction in pathological tremor power through controlling the impedance of the human-machine interface. Position, rate, and acceleration feedback are examined and two techniques for the selection of feedback coefficients are discussed. Both techniques seek a desired closed-loop human-machine frequency response and require the development of open-loop human-machine models through system identification. The design techniques were used to develop a tremor suppression system that was subsequently evaluated using human subjects. It is concluded that nonadaptive tremor suppression systems that utilize impedance control to achieve a specified reduction in tremor power can be successfully designed when accurate open-loop human-machine models are available.

[1]  Karin Hollerbach MODELING HUMAN ARM MOVEMENTS CONSTRAINED BY ROBOTIC SYSTEMS , 2002 .

[2]  K.E. Barner,et al.  Filtering involuntary motion of people with tremor disability using optimal equalization , 1995, 1995 IEEE International Conference on Systems, Man and Cybernetics. Intelligent Systems for the 21st Century.

[3]  W. Koller,et al.  Tremor disorders. Diagnosis and management. , 1995, The Western journal of medicine.

[4]  S. Haykin,et al.  Adaptive Filter Theory , 1986 .

[5]  Mark L. Nagurka,et al.  Dynamic and loaded impedance components in the maintenance of human arm posture , 1993, IEEE Trans. Syst. Man Cybern..

[6]  R N Stiles Lightly damped hand oscillations: acceleration-related feedback and system damping. , 1983, Journal of neurophysiology.

[7]  Cameron N. Riviere,et al.  Modeling and canceling tremor in human-machine interfaces , 1996 .

[8]  Simon Haykin,et al.  Adaptive filter theory (2nd ed.) , 1991 .

[9]  A S Arnold,et al.  Evaluation of a controlled-energy-dissipation orthosis for tremor suppression. , 1993, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[10]  W J Becker,et al.  Le Journal Canadien Des Sciences Neurologiques Manual Tracking Performance in Patients with Cerebellar Incoordination: Effects of Mechanical Loading , 2022 .

[11]  John G. Proakis,et al.  Digital Signal Processing: Principles, Algorithms, and Applications , 1992 .

[12]  A S Arnold,et al.  Design of a controlled-energy-dissipation orthosis (CEDO) for functional suppression of intention tremors. , 1995, Journal of rehabilitation research and development.