Myocardial perfusion imaging by contrast echocardiography with use of intracoronary sonicated albumin in humans.

Sonicated albumin has been proposed as a near ideal echocardiographic contrast agent with little myocardial toxicity or hemodynamic effect. Its use has not yet been reported in humans, partly because of difficulties in preparation. With use of the newly modified sonication method, 10 ml of 5% albumin was sonicated for 75 s with a 5.0 ml slow infusion of air. This resulted in microbubbles with a mean diameter (+/- SD) of 5 +/- microns). Fourteen patients undergoing routine coronary angiography were studied. One patient had normal coronary arteries; the other 13 had significant coronary artery disease. In a subgroup of nine patients, sonicated albumin and sonicated diatrizoate meglumine sodium (microbubble diameter 9 +/- 3 microns) were injected several minutes apart, using the same technique. Videodensity-time curves were obtained from a region of interest in the myocardium. Corrected peak contrast intensity (baseline contrast intensity subtracted from peak contrast intensity, gray scale U/pixel) for sonicated albumin and for sonicated diatrizoate meglumine sodium was 51 +/- 26 and 52 +/- 19, respectively (p = 0.89). Washout half-time (T1/2) for the two agents was 5.5 +/- 4.5 and 16.0 +/- 12.2 s, respectively (p = 0.01). One patient with unstable angina experienced transient chest pain after repeated albumin injections. No electrocardiographic changes, blood pressure changes or wall motion abnormalities were observed. Administered by intracoronary injection, sonicated 5% albumin is a safe and effective echocardiographic contrast agent for myocardial perfusion imaging, yielding excellent myocardial contrast with physiologic washout time.

[1]  S. Feinstein,et al.  Successful left ventricular opacification following peripheral venous injection of sonicated contrast agent: an experimental evaluation. , 1987, American heart journal.

[2]  E. G. Tickner,et al.  Assessment of Myocardial Perfusion Abnormalities with Contrast‐enhanced Two‐dimensional Echocardiography , 1982, Circulation.

[3]  S. Kaul,et al.  Myocardial contrast echocardiography without significant hemodynamic effects or reactive hyperemia: a major advantage in the imaging of regional myocardial perfusion. , 1988, Journal of the American College of Cardiology.

[4]  J. Roelandt,et al.  Myocardial perfusion imaging in humans by contrast echocardiography using polygelin colloid solution. , 1985, Journal of the American College of Cardiology.

[5]  C. Tei,et al.  Hyperemic response of intracoronary contrast agents during two-dimensional echographic delineation of regional myocardium. , 1984, Journal of the American College of Cardiology.

[6]  J. Carroll,et al.  Contrast Echocardiography During Coronary Arteriography in Humans: Perfusion and Anatomic Studies , 1988, Journal of the American College of Cardiology.

[7]  S. Kaul,et al.  Myocardial contrast echocardiography in humans: I. Safety--a comparison with routine coronary arteriography. , 1986, Journal of the American College of Cardiology.

[8]  R. Meltzer,et al.  Myocardial contrast two-dimensional echocardiography: dose-myocardial effect relations of intracoronary microbubbles. , 1988, Journal of the American College of Cardiology.

[9]  F J Ten Cate,et al.  Two-dimensional contrast echocardiography. I. In vitro development and quantitative analysis of echo contrast agents. , 1984, Journal of the American College of Cardiology.

[10]  E. Sowton,et al.  Contrast perfusion echocardiography: distribution and reproducibility of myocardial contrast enhancement in coronary artery disease. , 1987, The American journal of cardiology.

[11]  S. Meerbaum Promise and status of myocardial contrast-enhanced two-dimensional echocardiography: delineation of ischemic risk zone and quantitation of myocardial perfusion defects. , 1986, Journal of the American College of Cardiology.

[12]  K. Schwarz,et al.  Sonication of echo-contrast agents: a standardized and reproductible method , 1988 .

[13]  G. Maurer,et al.  Myocardial contrast two-dimensional echocardiography: comparison of contrast disappearance rates in normal and underperfused myocardium. , 1984, Circulation.