A Fast Transient Response Single Phase Active Power Filter

In this paper a fast dynamic response single phase active power filter is proposed. The method proposed, compensates the non-linear load by improving the power factor to the desired value and also eliminates the harmonics. The scheme is shown to work for both types compensation i.e. power factor correction plus harmonic elimination and harmonic elimination only under sinusoidal and non-sinusoidal supply voltage conditions. The active power filter (compensator) is realized using a single-phase voltage source inverter operated in a hysteresis current control mode. The method is validated through digital simulation results using MATLAB. The results have been shown with ideal and practical compensator with an emphasis on dynamic performance.

[1]  H.-L. Jou,et al.  Simplified control method for the single-phase active power filter , 1996 .

[2]  Marek Roch,et al.  Single-phase power active filter and compensator using instantaneous reactive power method , 2002 .

[3]  Juan Dixon,et al.  A simple control scheme for hybrid active power filter , 2002 .

[4]  M. T. Haque Single-phase PQ theory , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[5]  M. Tarafdar Haque Single-phase pq theory for active filters , 2002, 2002 IEEE Region 10 Conference on Computers, Communications, Control and Power Engineering. TENCOM '02. Proceedings..

[6]  Luowei Zhou,et al.  A novel active power filter based on the least compensation current control method , 2000 .

[7]  N. Matsui,et al.  A control strategy of single-phase active filter using a novel d-q transformation , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[8]  V.J. Farias,et al.  Active power filter control based on imposition of input sinusoidal current , 1997, PESC97. Record 28th Annual IEEE Power Electronics Specialists Conference. Formerly Power Conditioning Specialists Conference 1970-71. Power Processing and Electronic Specialists Conference 1972.

[9]  David A. Torrey,et al.  Single-phase active power filters for multiple nonlinear loads , 1995 .

[10]  M.R. Iravani,et al.  A signal Processing system for extraction of harmonics and reactive current of single-phase systems , 2004, IEEE Transactions on Power Delivery.

[11]  C. Y. Hsu,et al.  A new single-phase active power filter with reduced energy-storage capacity , 1996 .

[12]  J.W. Dixon,et al.  A simple frequency-independent method for calculating the reactive and harmonic current in a nonlinear load , 1996, IEEE Trans. Ind. Electron..