B0 field inhomogeneity considerations in pseudo‐continuous arterial spin labeling (pCASL): effects on tagging efficiency and correction strategy

Pseudo‐continuous arterial spin labeling (pCASL) is a very powerful technique to measure cerebral perfusion, which circumvents the problems affecting other continuous arterial spin labeling schemes, such as magnetization transfer and duty cycle. However, some variability in the tagging efficiency of the pCASL technique has been reported. This article investigates the effect of B0 field inhomogeneity on the tagging efficiency of the pCASL pulse sequence as a possible cause of this variability. Both theory and simulated data predict that the efficiency of pseudo‐continuous labeling pulses can be degraded in the presence of off‐resonance effects. These findings are corroborated by human in vivo measurements of tagging efficiency. On the basis of this theoretical framework, a method utilizing B0 field map information is proposed to correct for the possible loss in tagging efficiency of the pCASL pulse sequence. The efficiency of the proposed correction method is evaluated using numerical simulations and in vivo implementation. The data show that the proposed method can effectively recover the lost tagging efficiency and signal‐to‐noise ratio of pCASL caused by off‐resonance effects. Copyright © 2011 John Wiley & Sons, Ltd.

[1]  Gregory R. Lee,et al.  Fast, pseudo‐continuous arterial spin labeling for functional imaging using a two‐coil system , 2004, Magnetic resonance in medicine.

[2]  D. S. Williams,et al.  Magnetic resonance imaging of perfusion using spin inversion of arterial water. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[3]  T. Farr,et al.  Use of Magnetic Resonance Imaging to Predict Outcome after Stroke: A Review of Experimental and Clinical Evidence , 2010, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[4]  Thomas T. Liu,et al.  Analysis and Design of Perfusion-Based Event-Related fMRI Experiments , 2002, NeuroImage.

[5]  J. Detre,et al.  Multisection cerebral blood flow MR imaging with continuous arterial spin labeling. , 1998, Radiology.

[6]  D. Holdsworth,et al.  Characterization of common carotid artery blood-flow waveforms in normal human subjects , 1999, Physiological measurement.

[7]  Ove Almkvist,et al.  Voxel- and VOI-based analysis of SPECT CBF in relation to clinical and psychological heterogeneity of mild cognitive impairment , 2003, NeuroImage.

[8]  J. Detre,et al.  A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling , 2007, Magnetic resonance in medicine.

[9]  R B Buxton,et al.  A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging , 1998, Magnetic resonance in medicine.

[10]  Carroll,et al.  Whole Brain Pseudo Continuous ASL at 7 T Using a Single Coil for Imaging and Labeling 1077 , 2009 .

[11]  J. Arndt,et al.  The diameter of the intact carotid artery in man and its change with pulse pressure , 2004, Pflüger's Archiv für die gesamte Physiologie des Menschen und der Tiere.

[12]  Xavier Golay,et al.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla , 2004, Magnetic resonance in medicine.

[13]  Albert Macovski,et al.  Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T , 1991 .

[14]  M. Gado,et al.  Projection angiograms of blood labeled by adiabatic fast passage , 1986, Magnetic resonance in medicine.

[15]  D. C. Noll,et al.  Correcting for off-resonance induced degradation of inversion efficiency in pseudo-continuous ASL , 2008 .

[16]  Eric C Wong,et al.  Vessel‐encoded arterial spin‐labeling using pseudocontinuous tagging , 2007, Magnetic resonance in medicine.

[17]  D. Alsop,et al.  Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields , 2008, Magnetic resonance in medicine.

[18]  J. Detre,et al.  Assessment of cerebral blood flow in Alzheimer's disease by spin‐labeled magnetic resonance imaging , 2000, Annals of neurology.

[19]  Seong-Gi Kim Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping , 1995, Magnetic resonance in medicine.

[20]  Douglas C Noll,et al.  Advanced three‐dimensional tailored RF pulse for signal recovery in T2*‐weighted functional magnetic resonance imaging , 2006, Magnetic resonance in medicine.