Comparative Study of the Behavior of a Wind Farm Integrating Three Different FACTS Devices

Improving grid connection of wind farms is a relevant issue to be addressed, especially for fixed-speed wind turbines. Certain elements, such as FACTS (Flexible AC Transmission Systems), are able to perform voltage and reactive power regulation in order to support voltage stability of wind farms, and compensate reactive power consumption from the grid. Several devices are grouped under the name of FACTS, which embrace different technologies and operating principles. Here, three of them are evaluated and compared, namely STATCOM (Static Synchronous Compensator), SVC (Static Var Compensator) and SSSC (Static Synchronous Series Compensator). They have been modeled in MATLAB / Simulink, and simulated under various scenarios, regarding both normal operation and grid fault conditions. Their response is studied together with the case when no FACTS are implemented. Results show that SSSC improves the voltage stability of the wind farm, whereas STATCOM and SVC provide additional reactive power.

[1]  K. Uhlen,et al.  Large-scale wind power integration and voltage stability limits in regional networks , 2002, IEEE Power Engineering Society Summer Meeting,.

[2]  Ren-Xi Gong,et al.  Effect of Circuit Parameters on Stability of Voltage-fed Buck-Boost Converter in Discontinuous Conduction Mode , 2014 .

[3]  Hemanshu R. Pota,et al.  Robust STATCOM control for the stabilisation of fixed-speed wind turbines during low voltages , 2011 .

[4]  Marcelo G. Molina,et al.  Modeling and Control of Integrated STATCOM-SMES System to Improve Power System Oscillations Damping , 2008 .

[5]  Xiao-Ping Zhang,et al.  Flexible AC Transmission Systems: Modelling and Control , 2006 .

[6]  Sarath B. Tennakoon,et al.  Evaluation of the suitability of a fixed speed wind turbine for large scale wind farms considering the new UK grid code , 2008 .

[7]  N. Senthil Kumar,et al.  Impact of FACTS controllers on the stability of power systems connected with doubly fed induction generators , 2011 .

[8]  R. P. Kumudini Devi,et al.  Steady-state analysis of Grid connected WECS using FACTS controller , 2011, 2011 International Conference on Emerging Trends in Electrical and Computer Technology.

[9]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[10]  Luis M. Fernández,et al.  Dynamic models of wind farms with fixed speed wind turbines , 2006 .

[11]  Gilsoo Jang,et al.  Real-Time Hardware Simulator for Grid-Tied PMSG Wind Power System , 2011 .

[12]  Julio Usaola,et al.  Incidence on Power System Dynamics of High Penetration of Fixed Speed and Doubly Fed Wind Energy Systems: Study of the Spanish Case , 2002, IEEE Power Engineering Review.

[13]  Hamid Lesani,et al.  Effects of STATCOM, TCSC, SSSC and UPFC on static voltage stability , 2011 .

[14]  Hans Knudsen,et al.  Large penetration of wind and dispersed generation into Danish power grid , 2007 .

[15]  Hortensia Amaris,et al.  A multiobjective approach for reactive power planning in networks with wind power generation , 2012 .

[16]  Gilsung Byeon,et al.  Modeling and Control of a Doubly-Fed Induction Generator (DFIG) Wind Power Generation System for Real-time Simulations , 2010 .

[17]  Pedro G. Barbosa,et al.  Flexible AC Transmission Systems , 2020, CIGRE Green Books.

[18]  Ying Hua Han,et al.  Grid Integration of Wind Energy Conversion Systems , 2000 .

[19]  Bharat Singh,et al.  Development of grid connection requirements for wind power generators in India , 2011 .

[20]  Sae-Hyuk Kwon,et al.  The Study of FACTS Impacts for Probabilistic Transient Stability , 2006 .

[21]  S.M. Muyeen,et al.  Wind Generator Output Power Smoothing and Terminal Voltage Regulation by Using STATCOM/ESS , 2007, 2007 IEEE Lausanne Power Tech.

[22]  Hemanshu R Pota,et al.  Simultaneous STATCOM and Pitch Angle Control for Improved LVRT Capability of Fixed-Speed Wind Turbines , 2010, IEEE Transactions on Sustainable Energy.

[23]  K. K. Sen SSSC-static synchronous series compensator: theory, modeling, and application , 1998 .

[24]  S. Bacha,et al.  Real-Time Analysis of the Transient Response Improvement of Fixed-Speed Wind Farms by Using a Reduced-Scale STATCOM Prototype , 2007, IEEE Transactions on Power Systems.

[25]  Mansour Mohseni,et al.  Review of international grid codes for wind power integration: Diversity, technology and a case for global standard , 2012 .

[26]  Mike Barnes,et al.  Power quality and stability improvement of a wind farm using STATCOM supported with hybrid battery energy storage , 2006 .

[27]  B. Han,et al.  Real-Time Hardware Simulator for Grid-Tied PMSG Wind Power System , 2012 .

[28]  Frede Blaabjerg,et al.  Stability improvement of induction generator-based wind turbine systems , 2007 .

[29]  Ghadir Radman,et al.  Dynamic model for power systems with multiple FACTS controllers , 2008 .

[30]  Goran Strbac,et al.  Application of STATCOMs to wind farms , 1998 .

[31]  Laszlo Gyugyi,et al.  Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems , 1999 .

[32]  M. Kenan Dösoglu,et al.  Investigation of different load changes in wind farm by using FACTS devices , 2012, Adv. Eng. Softw..

[33]  Pavlos S. Georgilakis,et al.  Technical challenges associated with the integration of wind power into power systems , 2008 .

[34]  D. Aouzellag,et al.  Contribution to the improvement of voltage profile in electrical network with wind generator using SVC device , 2010 .

[35]  Dionisio Ramirez,et al.  Use of STATCOM in wind farms with fixed-speed generators for grid code compliance , 2012 .

[36]  L. Imaz,et al.  Large integration of wind power: the Spanish experience , 2007, 2007 IEEE Power Engineering Society General Meeting.