Potentiometric Determination of Cyclizine by a PVC membrane Sensor

[1]  Ashutosh Kumar Singh,et al.  A novel gadolinium ion-selective membrane electrode based on 2-(4-phenyl-1, 3-thiazol-2-yliminomethyl) phenol , 2013 .

[2]  Mohammad Reza Ganjali,et al.  A Ho(III) potentiometric polymeric membrane sensor based on a new four dentate neutral ion carrier. , 2013, Materials science & engineering. C, Materials for biological applications.

[3]  Mohammad Reza Ganjali,et al.  Fabrication of a PVC membrane samarium(III) sensor based on N,N',N"-tris(4-pyridyl)trimesic amide as a selectophore. , 2013, Materials science & engineering. C, Materials for biological applications.

[4]  M. Ganjali,et al.  Dysprosium selective potentiometric membrane sensor. , 2013, Materials science & engineering. C, Materials for biological applications.

[5]  S. Chandra,et al.  Novel thiocyanate ion-selective electrodes based on a copper(II) complex of p-hydroxyacetophenone thiosemicarbazone as a carrier , 2013, Monatshefte für Chemie - Chemical Monthly.

[6]  Mohammad Reza Ganjali,et al.  Gadolinium(III) ion selective sensor using a new synthesized Schiff's base as a sensing material , 2012 .

[7]  M. Ganjali,et al.  Europium (III) PVC membrane sensor based on N-pyridine-2-carboxamido-8-aminoquinoline as a sensing material , 2012 .

[8]  M. Ganjali,et al.  Heptadentate Schiff-base based PVC membrane sensor for Fe(III) ion determination in water samples , 2012 .

[9]  M. Ganjali,et al.  Application of 1-ethyl-3-(2,5-dihydro-4-(3,5-dimethyl-1H-pyrazol-4-yl)-5-oxo-1H-pyrazol-3-yl)thiourea as sensing material for construction of Tm3+-PVC membrane sensor , 2011 .

[10]  M. Ganjali,et al.  Neodymium(III)–PVC membrane sensor based on a new four dentate ionophore , 2011 .

[11]  M. Ganjali,et al.  Di-tert-butylazodicarboxylate based PVC membrane sensor for Fe(III) ion measurement in pharmaceutical formulation , 2011 .

[12]  M. Ganjali,et al.  Determination of zinc(II) ions in waste water samples by a novel zinc sensor based on a new synthesized Schiff's base , 2011 .

[13]  M. Ganjali,et al.  Praseodymium analysis in aqueous solution by Pr3+–PVC membrane sensor based on N,N′-bis(4-hydroxysalicylidene)-1-3-phenylenediamine , 2011 .

[14]  M. Ganjali,et al.  Ho3+ carbon paste sensor based on multi-walled carbon nanotubes: Applied for determination of holmium content in biological and environmental samples , 2010 .

[15]  M. Ganjali,et al.  Construction of Tm3+-PVC membrane sensor based on 1-(2-thiazolylazo)-2-naphthol as sensing material , 2010 .

[16]  M. Ganjali,et al.  Fabrication of an iron(III) PVC-membrane sensor based on bis-benzilthiocarbohydrazide as a selective sensing material , 2009 .

[17]  M. Ganjali,et al.  Lanthanide recognition: A Ho3+ potentiometric membrane sensor as a probe for determination of terazosin , 2009 .

[18]  M. Ganjali,et al.  2,3-Diphenylquinoxaline-4′,4″-dioxytriethylene glycol as a sensing and selective material for construction of strontium-PVC membrane sensor , 2009 .

[19]  M. Ganjali,et al.  Application of Adsorptive Voltammetry for the Detection of Sub-nano Molar Cyclizine in Biological Fluids and Tablets Using Fast Fourier Transform Continuous Cyclic Voltammetry in a Flowing System , 2009, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[20]  M. Ganjali,et al.  Application of a New Tramadol Potentiometric Membrane Sensor as a Useful Device for Tramadol Hydrochloride Analysis in Pharmaceutical Formulation and Urine , 2009 .

[21]  M. Ganjali,et al.  A novel iron (III)-PVC membrane potentiomeric sensor based on N-(2-hydroxyethyl)ethylenediamine-N,N',N"-triacetic acid , 2008 .

[22]  M. Ganjali,et al.  Determination of terbium(III) ions in phosphate rock samples by a Tb3+–PVC membrane sensor based on N, N-Dimethyl-N′, N″-bis(4-methoxyphenyl)phosphoramidate , 2008 .

[23]  Mohammad Reza Ganjali,et al.  Application of GA-MLR, GA-PLS and the DFT quantum mechanical (QM) calculations for the prediction of the selectivity coefficients of a histamine-selective electrode , 2008 .

[24]  M. Ganjali,et al.  Application of Novel Praseodymium (III) PVC‐Membrane Electrode for Determination of Pr(III) Ions in Soil and Sediment Samples , 2008 .

[25]  M. Ganjali,et al.  Molecularly imprinted polymer based potentiometric sensor for the determination of hydroxyzine in tablets and biological fluids. , 2008, Analytica chimica acta.

[26]  M. Ganjali,et al.  Strontium PVC-membrane sensor based on 2-[(2-mercaptophenylimino)methyl]phenol , 2008 .

[27]  M. Ganjali,et al.  Determination of neodymium(III) ions in soil and sediment samples by a novel neodymium(III) sensor based on benzyl bisthiosemicarbazone , 2007 .

[28]  M. Ganjali,et al.  Procaine as a Sensing Material for Determination of Dysprosium(III) Ions in Presence of Other Rare‐earth Elements in Biological and Environmental Samples , 2007 .

[29]  M. Ganjali,et al.  Cr(III) Ion-Selective Membrane Sensor Based on 1,3-Diamino-2-Hydroxypropane-N,N,N′,N′ Tetraacetic Acid , 2007 .

[30]  Mohammad Reza Ganjali,et al.  Carbon Paste Electrode Modified with Functionalized Nanoporous Silica Gel as a New Sensor for Determination of Silver Ion , 2007, Electroanalysis.

[31]  M. Ganjali,et al.  A new ytterbium(III) PVC membrane electrode based on 6-methy-4-{[1-(1H-pyrrol-2-yl)methylidene]amino}-3-thioxo-3,4dihydro-1,2,4-triazin-5(2H)-one. , 2007, Talanta.

[32]  M. Ganjali,et al.  Fabrication of a novel holmium(III) PVC membrane sensor based on 4-chloro-1,2-bis(2-pyridinecarboxamido)benzene as a neutral ionophore , 2007 .

[33]  M. Ganjali,et al.  Cd(II) PVC-Based Membrane Sensor Based on N ′-[1-(2-furyl)methylidene]-2-furohydrazide , 2006 .

[34]  Ashutosh Kumar Singh,et al.  A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N'-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine. , 2006, Analytica chimica acta.

[35]  M. Ganjali,et al.  A Novel Holmium(III) Membrane Sensor Based on N‐(1‐Thien‐2‐Ylmethylene)‐1,3‐Benzothiazol‐2‐Amine , 2006 .

[36]  M. Ganjali,et al.  Highly selective and sensitive thiocyanate membrane electrode based on nickel(II)-1,4,8,11,15,18,22,25-octabutoxyphthalocyanine , 2006 .

[37]  R. Ludwig,et al.  Anion recognition through modified calixarenes: a highly selective sensor for monohydrogen phosphate , 2005 .

[38]  V. Gupta,et al.  Anion recognition through novel C-thiophenecalix[4]resorcinarene: PVC based sensor for chromate ions. , 2005, Talanta.

[39]  E. Houghton,et al.  Biotransformation of cyclizine in greyhounds. 1: identification and analysis of cyclizine and some basic metabolites in canine urine by gas chromatography-mass spectrometry , 2002, Xenobiotica; the fate of foreign compounds in biological systems.

[40]  M. Shamsipur,et al.  Highly selective thiocyanate poly(vinyl chloride) membrane electrode based on a cadmium–Schiff’s base complex , 2001, Fresenius' journal of analytical chemistry.

[41]  M. Shamsipur,et al.  Lead Ion-Selective Electrode Based on 4′-Vinylbenzo-15-crown-5 Homopolymer , 1998 .

[42]  Suresh S. Jain,et al.  A PVC‐based benzo‐15‐crown‐5 membrane sensor for cadmium , 1996 .

[43]  R. Baselt,et al.  Blood and urine concentrations of cyclizine by nitrogen-phosphorus gas-liquid chromatography. , 1984, Journal of analytical toxicology.

[44]  A. G. Davidson,et al.  Assay of benzenoid drugs in tablet and capsule formulations by second-derivative ultraviolet spectrophotometry. , 1984, Journal of pharmaceutical sciences.

[45]  M. E. Frantz,et al.  Prevention of airsickness among airborne troops. , 1953, Journal of applied physiology.

[46]  M. Ganjali,et al.  Neutral N,N′-bis(2-pyridinecarboxamide)-1,2-ethane as sensing material for determination of lutetium(III) ions in biological and environmental samples , 2009 .