Hounsfield units variations

PurposeDetermination of dose error margins in radiation therapy planning due to variations in Hounsfield Units (HU) values dependent on the use of different CT scanning protocols.Patients and methodsBased on a series of different CT scanning protocols used in clinical practice, conversion tables for radiation dose calculations were generated and subsequently tested on a phantom. These tables were then used to recalculate the radiation therapy plans of 28 real patients after an incorrect scanning protocol had inadvertently been used for these patients.ResultsDifferent CT parameter settings resulted in errors of HU values of up to 2.6 % for densities of < 1.1 g/cm3, but up to 25.6 % for densities of > 1.1 g/cm3. The largest errors were associated with changes in the tube voltage. Tests on a virtual water phantom with layers of variable thickness and density revealed a sawtooth-shaped curve for the increase of dose differences from 0.3 to 0.6 % and 1.5 % at layer thicknesses of 1, 3, and 7 cm, respectively. Use of a beam hardening filter resulted in a reference dose difference of 0.6 % in response to a density change of 5 %. The recalculation of data from 28 patients who received radiation therapy to the head revealed an overdose of 1.3 ± 0.4 % to the bone and 0.7 ± 0.1 % to brain tissue. On average, therefore, one monitor unit (range 0–3 MU) per 100 MU more than the correct dose had been given.ConclusionUse of different CT scanning protocols leads to variations of up to 20 % in the HU values. This can result in a mean systematic dose error of 1.5 %. Specific conversion tables and automatic CT scanning protocol recognition could reduce dose errors of these types.ZusammenfassungHintergrundBestimmung von Dosisunsicherheiten in der Bestrahlungsplanung durch Schwankungen der Hounsfield-Einheiten (HU) bei Verwendung unterschiedlicher CT-Protokolle.Patienten und MethodenAnhand unterschiedlicher klinisch verwendeter CT-Scan-Protokolle wurden Konversionstabellen zur Dosisberechnung erstellt und im Phantom getestet. Unter Zuhilfenahme dieser Tabellen wurden 28 reale Bestrahlungspläne nachgerechnet, nachdem bei diesen Patienten irrtümlich ein ungeeignetes Scan-Protokoll verwendet worden war.ErgebnisseUnterschiedliche CT-Einstellungsparameter zeigten für Dichten < 1,1 g/cm3 HU-Schwankungen bis zu 2,6 %, bei Dichten > 1,1 g/cm3 jedoch Abweichungen bis zu 25,6 %. Die größten Schwankungen traten bei Änderung der Röhrenspannung auf. Untersuchungen am virtuellen Wasserphantom mit Schichten unterschiedlicher Dicke und Dichte zeigten einen sägezahnartigen Anstieg der Dosisänderungen von 0,3%, 0,6% und 1,5 % bei Schichtstärken von 1, 3 und 7 cm. Bei Verwendung eines „Beam-hardening“-Filters resultierte bei einer Dichteänderung von 5 % eine Referenzdosisänderung von 0,6 %. Die Rekalkulation von 28 Patienten mit Bestrahlungen im Schädelbereich zeigte bei Verwendung der korrekten Konversionstabelle eine Überdosierung im Knochenbereich von 1,3 ± 0,4 % und im Bereich der Gehirnmasse von 0,7 ± 0,1 %. Im Mittel wurde somit zusätzlich eine Monitoreinheit (Spanne 0–3 MU) pro 100 MU verabreicht.SchlussfolgerungDie Verwendung verschiedener CT-Scan-Protokolle führt zu HU-Abweichungen von bis zu 20 %. Dies kann einen mittleren systematischen Dosisfehler von 1,5 % verursachen. Spezifische Konversionstabellen und automatische CT-Protokollerkennung könnten Dosisungenauigkeiten dieser Art reduzieren.

[1]  P. Kukołowicz,et al.  Computed Tomography as a Source of Electron Density Information for Radiation Treatment Planning , 2010, Strahlentherapie und Onkologie.

[2]  E C McCullough,et al.  The use of CT scanners in megavoltage photon-beam therapy planning. , 1977, Radiology.

[3]  L Cozzi,et al.  Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  Matthias Guckenberger,et al.  Investigation of the usability of conebeam CT data sets for dose calculation , 2008, Radiation oncology.

[5]  J. Cygler,et al.  Commissioning and quality assurance of treatment planning computers. , 1993, International journal of radiation oncology, biology, physics.

[6]  Warren Kilby,et al.  Tolerance levels for quality assurance of electron density values generated from CT in radiotherapy treatment planning. , 2002, Physics in medicine and biology.

[7]  Comparison between Acuros XB and Brainlab Monte Carlo algorithms for photon dose calculation , 2012, Strahlentherapie und Onkologie.

[8]  H. Böttcher,et al.  Influence of CT contrast agents on dose calculations in a 3D treatment planning system. , 2001, Physics in medicine and biology.

[9]  N. Licht,et al.  Dosimetric properties and commissioning of cone-beam CT image beam line with a carbon target , 2013, Strahlentherapie und Onkologie.

[10]  Huaiqun Guan,et al.  Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy , 2009, Physics in medicine and biology.

[11]  G. Starkschall,et al.  American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning. , 1998, Medical physics.

[12]  M. Sontag,et al.  On the impact of CT scanning on radiotherapy planning. , 1980, Computerized tomography.

[13]  Steve Webb,et al.  Cone beam computed tomography number errors and consequences for radiotherapy planning: an investigation of correction methods. , 2012, International journal of radiation oncology, biology, physics.

[14]  S. Thomas,et al.  Relative electron density calibration of CT scanners for radiotherapy treatment planning. , 1999, The British journal of radiology.

[15]  J. Cheng,et al.  Practically acquired and modified cone-beam computed tomography images for accurate dose calculation in head and neck cancer , 2011, Strahlentherapie und Onkologie.

[16]  Peter Winkler,et al.  [Analysis of image quality and dose calculation accuracy in cone beam CT acquisitions with limited projection data (half scan, half fan) with regard to usability for adaptive radiation therapy treatment planning]. , 2011, Zeitschrift fur medizinische Physik.

[17]  Untersuchung von Bildqualität und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit für die adaptive Bestrahlungsplanung , 2011 .

[18]  F. Lohr,et al.  Rechtliche Grundlagen für den Umgang mit sicherheitsrelevanten Ereignissen in der Strahlentherapie , 2012, Strahlentherapie und Onkologie.

[19]  Boyd McCurdy,et al.  Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy , 2009, Physics in medicine and biology.

[20]  J. Debus,et al.  Influence of Intravenous Contrast Agent on Dose Calculation in 3-D Treatment Planning for Radiosurgery of Cerebral Arteriovenous Malformations , 2009, Strahlentherapie und Onkologie.

[21]  B Mijnheer,et al.  Tolerances for the accuracy of photon beam dose calculations of treatment planning systems. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.