Spatial filtering of unipolar electrograms

In order to be able to derive some quantitative criteria to assist in making decisions about the presence of local activations, zones of canine myocardium incapable of undergoing electrical activation (EA) were created. The criteria are based on the comparison of electrograms recorded in those inexcitable zones with electrograms recorded in normal myocardium. Two criteria for making decisions about local EA in unipolar electrograms are compared. The first is based on the first time derivative (time filtering) of the electrogram and the second is based on th first spatial derivative (spatial filtering) between two electrograms recorded in neighboring electrodes. It is shown that the spatial derivative performs much better than the time derivative in both supraventricular rhythm and ventricular fibrillation.<<ETX>>

[1]  Robert Guardo,et al.  An Integrated System for Intraoperative Cardiac Activation Mapping , 1987, IEEE Transactions on Biomedical Engineering.

[2]  R. Ideker,et al.  Computer techniques for epicardial and endocardial mapping. , 1983, Progress in cardiovascular diseases.

[3]  Michiel J. Janse,et al.  An Interactive Computer System for Guiding the Surgical Treatment of Life-Threatening Ventricular Tachycardias , 1984, IEEE Transactions on Biomedical Engineering.

[4]  Thomas Lewis,et al.  The excitatory process in the dog's heart. Part II The ventricles , 1915 .

[5]  R. Ideker,et al.  The Transition to Ventricular Fibrillation Induced by Reperfusion After Acute Ischemia in the Dog: A Period of Organized Epicardial Activation , 1981, Circulation.

[6]  C. Metz Basic principles of ROC analysis. , 1978, Seminars in nuclear medicine.

[7]  W.M. Smith,et al.  Activation in unipolar cardiac electrograms: a frequency analysis , 1990, IEEE Transactions on Biomedical Engineering.

[8]  Raymond E. Ideker,et al.  Classification of Heart Tissue from Bipolar and Unipolar Intramural Potentials , 1985, IEEE Transactions on Biomedical Engineering.

[9]  Ralph J. Damiano,et al.  The Effects of Distant Cardiac Electrical Events on Local Activation in Unipolar Epicardial Electrograms , 1987, IEEE Transactions on Biomedical Engineering.

[10]  D. Geselowitz,et al.  A cardiac mapping system for identifying late potentials: correlation with signal averaged surface recordings , 1988, Proceedings. Computers in Cardiology 1988.

[11]  An automatic activation detector for bipolar cardiac electrograms , 1988, Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  Ian D. Parson,et al.  Cardiac Mapping Instrumentation for the Instantaneous Display of Endocardial and Epicardial Activation , 1987, IEEE Transactions on Biomedical Engineering.

[13]  P. Wolf,et al.  Mechanism of Ventricular Vulnerability to Single Premature Stimuli in Open‐Chest Dogs , 1988, Circulation research.

[14]  F. Witkowski,et al.  An automated simultaneous transmural cardiac mapping system. , 1984, The American journal of physiology.

[15]  Raymond E. Ideker,et al.  Use of coherence in activation detection during ventricular fibrillation , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[16]  S. M. Blanchard,et al.  Computed bipolar electrograms from unipolar epicardial recordings , 1988, Proceedings. Computers in Cardiology 1988.