Making use of ion fluxes through potentiometric sensor membranes: ISEs with step responses at critical ion activities
暂无分享,去创建一个
[1] E. Bakker,et al. Improved detection limits and sensitivities of potentiometric titrations. , 2001, Analytical chemistry.
[2] E. Pretsch,et al. Influence of key parameters on the lower detection limit and response function of solvent polymeric membrane ion-selective electrodes , 2001 .
[3] B. Hattendorf,et al. Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels: new requirements for selectivities and measuring protocols, and comparison with ICPMS. , 2001, Analytical chemistry.
[4] Qin,et al. Improved detection limits and unbiased selectivity coefficients obtained by using ion-exchange resins in the inner reference solution of ion-selective polymeric membrane electrodes , 2000, Analytical chemistry.
[5] M. Meyerhoff,et al. Ionophore-based membrane electrodes: New analytical concepts and non-classical response mechanisms , 2000 .
[6] E. Bakker,et al. Direct potentiometric information on total ionic concentrations. , 2000, Analytical chemistry.
[7] W. E. Morf,et al. Effects of ion transport on the potential response of ionophore-based membrane electrodes: a theoretical approach , 1999 .
[8] E. Bakker,et al. Detection limit of polymeric membrane potentiometric ion sensors: how can we go down to trace levels? , 1999 .
[9] E. Pretsch,et al. Steady‐State Model Calculations Predicting the Influence of Key Parameters on the Lower Detection Limit and Ruggedness of Solvent Polymeric Membrane Ion‐Selective Electrodes , 1999 .
[10] Ernö Pretsch,et al. Lowering the Detection Limit of Solvent Polymeric Ion-Selective Membrane Electrodes. 2. Influence of Composition of Sample and Internal Electrolyte Solution , 1999 .
[11] Ernö Pretsch,et al. Lowering the detection limit of solvent polymeric ion-selective electrodes. 1. Modeling the influence of steady-state ion fluxes , 1999 .
[12] E. Bakker,et al. Effect of Transmembrane Electrolyte Diffusion on the Detection Limit of Carrier-Based Potentiometric Ion Sensors , 1998 .
[13] E. Pretsch,et al. Large Improvement of the Lower Detection Limit of Ion-Selective Polymer Membrane Electrodes , 1997 .
[14] E. Bakker. Determination of Unbiased Selectivity Coefficients of Neutral Carrier-Based Cation-Selective Electrodes , 1997 .
[15] E. Bakker. Determination of Improved Selectivity Coefficients of Polymer Membrane Ion‐Selective Electrodes by Conditioning with a Discriminated Ion , 1996 .
[16] M. Meyerhoff,et al. Response mechanism of polymer membrane-based potentiometric polyion sensors. , 1994, Analytical chemistry.
[17] S. Kamata,et al. Copper(II)-selective electrode using thiuram disulfide neutral carriers , 1988 .
[18] G. Horvai,et al. Plasticized poly(vinyl chloride) properties and characteristics of valinomycin electrodes. Current-time responses to voltage steps. , 1988, Analytical chemistry.
[19] K. Stulík,et al. ION-Selective Electrodes , 1986 .
[20] W. E. Morf,et al. Cation-response mechanism of neutral carrier based ion-selective electrode membranes , 1986 .
[21] W. Simon,et al. Lipophilic Synthetic Monoamides of Dicarboxylic Acids as Ionophores for Alkaline Earth Metal Cations , 1982 .
[22] W. E. Morf,et al. Durch elektrisch geladene Ionophore induzierter Ionentransport in Modellmembranen mit Selektivität für Magnesium und Calcium , 1979 .
[23] W. E. Morf,et al. Mechanism of neutral carrier mediated ion transport through ion-selective bulk membranes , 1977 .
[24] W. E. Morf,et al. Transport properties of neutral carrier on selective membranes , 1976 .
[25] W. E. Morf,et al. Theoretical treatment of the dynamic response of ion-selective membrane electrodes , 1975 .
[26] W. E. Morf,et al. Theoretical treatment of the selectivity and detection limit of silver compound membrane electrodes , 1974 .
[27] R. Buck. Theory of potential distribution and response of solid state membrane electrodes. II. Nonzero current , 1968 .
[28] P. C. Meier. Two-parameter debye-hückel approximation for the evaluation of mean activity coefficients of 109 electrolytes , 1982 .
[29] A. Lewenstam,et al. Interpretation of selectivity coefficients of solid-state ion-selective electrodes by means of the diffusion-layer model. , 1977, Talanta.