Deblurring Computed Tomography Medical Images Using a Novel Amended Landweber Algorithm

In computed tomography (CT), blurring occurs due to different hardware or software errors and hides certain medical details that are present in an image. Image blur is difficult to avoid in many circumstances and can frequently ruin an image. For this, many methods have been developed to reduce the blurring artifact from CT images. The problems with these methods are the high implementation time, noise amplification and boundary artifacts. Hence, this article presents an amended version of the iterative Landweber algorithm to attain artifact-free boundaries and less noise amplification in a faster application time. In this study, both synthetic and real blurred CT images are used to validate the proposed method properly. Similarly, the quality of the processed synthetic images is measured using the feature similarity index, structural similarity and visual information fidelity in pixel domain metrics. Finally, the results obtained from intensive experiments and performance evaluations show the efficiency of the proposed algorithm, which has potential as a new approach in medical image processing.

[1]  Lei Liang,et al.  Adaptive Landweber method to deblur images , 2003, IEEE Signal Process. Lett..

[2]  Panos Liatsis,et al.  Medical Image Deblurring via Lagrangian Pursuit in Frame Dictionaries , 2011, 2011 Developments in E-systems Engineering.

[3]  P. K. Dutta,et al.  A blind-deconvolution approach for chromatographic and spectroscopic peak restoration , 1998, IEEE Trans. Instrum. Meas..

[4]  Alan C. Bovik,et al.  Image information and visual quality , 2006, IEEE Trans. Image Process..

[5]  Tai-hoon Kim,et al.  A Cognitive Study on Medical Imaging , 2010 .

[6]  Lee W Goldman,et al.  Principles of CT: Radiation Dose and Image Quality* , 2007, Journal of Nuclear Medicine Technology.

[7]  Liang Li,et al.  A novel metal artifact reducing method for cone-beam CT based on three approximately orthogonal projections , 2013, Physics in medicine and biology.

[8]  Jochen Hiller,et al.  A study on evaluation strategies in dimensional X-ray computed tomography by estimation of measurement uncertainties , 2012 .

[9]  F. Boas,et al.  CT artifacts: Causes and reduction techniques , 2012 .

[10]  Wensong Hu,et al.  Advances in Electric and Electronics , 2012 .

[11]  Xin Jin,et al.  A limited-angle CT reconstruction method based on anisotropic TV minimization , 2013, Physics in medicine and biology.

[12]  Tuan D. Pham,et al.  Supervised restoration of degraded medical images using multiple-point geostatistics , 2012, Comput. Methods Programs Biomed..

[13]  Filippo Attivissimo,et al.  A Technique to Improve the Image Quality in Computer Tomography , 2010, IEEE Transactions on Instrumentation and Measurement.

[14]  Stanley Osher,et al.  Image Recovery via Nonlocal Operators , 2010, J. Sci. Comput..

[15]  Liyi Zhang,et al.  Research of Medical Image Variable Step-Size Blind Restoration Algorithm , 2012 .

[16]  Lihong Huang,et al.  Split Bregman iteration algorithm for total bounded variation regularization based image deblurring , 2010 .

[17]  Ashish Khare,et al.  Daubechies Complex Wavelet Transform Based Multilevel Shrinkage for Deblurring of Medical Images in Presence of Noise , 2009, Int. J. Wavelets Multiresolution Inf. Process..

[18]  Jin Zhang,et al.  Neural Network Blind Equalization Algorithm Applied in Medical CT Image Restoration , 2013 .

[19]  Filippo Attivissimo,et al.  A statistical approach for MR and CT images comparison , 2013 .

[20]  David Zhang,et al.  FSIM: A Feature Similarity Index for Image Quality Assessment , 2011, IEEE Transactions on Image Processing.

[21]  Marc Moonen,et al.  Joint DOA and multi-pitch estimation based on subspace techniques , 2012, EURASIP J. Adv. Signal Process..

[22]  Kok-Swee Sim,et al.  Contrast enhancement of computed tomography images by adaptive histogram equalization‐application for improved ischemic stroke detection , 2012, Int. J. Imaging Syst. Technol..

[23]  Sabrina Rashid,et al.  An improved method for the removal of ring artifacts in high resolution CT imaging , 2012, EURASIP Journal on Advances in Signal Processing.

[24]  Michael S. Brown,et al.  Nonlinear Camera Response Functions and Image Deblurring: Theoretical Analysis and Practice , 2013, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[25]  R. Shantha Selva Kumari,et al.  Sharpening enhancement of Computed Tomography (CT) images using Hyperbolic Secant Square filter , 2013 .

[26]  Mehran Yazdi,et al.  Artifacts in Spiral X-ray CT Scanners: Problems and Solutions , 2007 .

[27]  Wiro J. Niessen,et al.  Selective Deblurring for Improved Calcification Visualization and Quantification in Carotid CT Angiography: Validation Using Micro-CT , 2009, IEEE Transactions on Medical Imaging.

[28]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[29]  Kiran S. Kunnur,et al.  A NOVEL APPROACH FOR IMAGE RESTORATION VIA NEAREST NEIGHBOUR METHOD , 2010 .

[30]  Hamid Reza Karimi,et al.  Missing Value Estimation for Microarray Data by Bayesian Principal Component Analysis and Iterative Local Least Squares , 2013 .

[31]  Marco Donatelli,et al.  A fast alternating minimization algorithm for total variation deblurring without boundary artifacts , 2013, 1308.6754.

[32]  S. Riad,et al.  Filtering capabilities and convergence of the Van-Cittert deconvolution technique , 1991 .