Wearable Sensing of Left Ventricular Function

Cardiovascular diseases (CVDs) cause nearly one third of all deaths worldwide, and are projected to afflict 40% of all Americans by the year 2030. According to the World Health Organization, CVDs can be prevented by early detection and management of risk factors—and consequent changes in behavior such as reducing tobacco use, increasing physical activity, and improving diet. Many CVDs are fundamentally associated with a weakening or damaged left ventricle (LV). Recent advances in wearable hemodynamics and cardiac timing measurement technologies present an exciting opportunity to achieve early detection and continuous monitoring of changes in LV function, and to then potentially affect behavior to reduce CVD prevalence. This chapter will (1) provide a brief introduction to LV physiology, (2) a description of key parameters such as stroke volume, cardiac output, and arterial blood pressure that capture LV function, (3) an introduction to heart failure as a key example of LV pathophysiology, (4) a discussion of wearable technologies for continuous and ubiquitous sensing of LV parameters using mHealth approaches, and (5) future directions and trends.

[1]  Omer T. Inan,et al.  Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time , 2016, Scientific Reports.

[2]  L. Rowell,et al.  Human Cardiovascular Adjustments to Rapid Changes in Skin Temperature during Exercise , 1969, Circulation research.

[3]  Kouhyar Tavakolian,et al.  Characterization and analysis of seismocardiogram for estimation of hemodynamic parameters , 2010 .

[4]  B WELLS,et al.  THE ASSESSMENT OF MITRAL STENOSIS BY PHONOCARDIOGRAPHY , 1954, British heart journal.

[5]  Carmen C. Y. Poon,et al.  Unobtrusive Sensing and Wearable Devices for Health Informatics , 2014, IEEE Transactions on Biomedical Engineering.

[6]  A Steptoe,et al.  Pulse wave velocity and blood pressure change: calibration and applications. , 1976, Psychophysiology.

[7]  Tzyy-Ping Jung,et al.  Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review , 2010, IEEE Reviews in Biomedical Engineering.

[8]  Mark V. Williams,et al.  Rehospitalizations among patients in the Medicare fee-for-service program. , 2009, The New England journal of medicine.

[9]  G. V. Marie,et al.  The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise. , 1984, Psychophysiology.

[10]  Lionel Tarassenko,et al.  Signal quality classification of mobile phone-recorded phonocardiogram signals , 2014, 2014 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[11]  R. Patterson,et al.  IMPEDANCE CARDIOGRAPHY AS A NONINVASIVE METHOD OF MONITORING CARDIAC FUNCTION AND OTHER PARAMETERS OF THE CARDIOVASCULAR SYSTEM * , 1970 .

[12]  Survi Kyal,et al.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice , 2015, IEEE Transactions on Biomedical Engineering.

[13]  L Giovangrandi,et al.  Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph , 2009, Physiological measurement.

[14]  J Licinio,et al.  Cardiovascular and neuroendocrine adjustment to public speaking and mental arithmetic stressors. , 1997, Psychophysiology.

[15]  J. Lekkala,et al.  Measurement of heart sounds with EMFi transducer , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  Carmen C. Y. Poon,et al.  An Evaluation of the Cuffless Blood Pressure Estimation Based on Pulse Transit Time Technique: a Half Year Study on Normotensive Subjects , 2009, Cardiovascular engineering.

[17]  Yan Chen,et al.  Continuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship Between Blood Pressure and Pulse Wave Velocity , 2009, Annals of Biomedical Engineering.

[18]  W. Nichols,et al.  Comprar Mcdonald's blood flow in arteries. Theoretical, experimental and clinical principles | W. Nichols | 9780340985014 | Hodder Education , 2011 .

[19]  J. Muehlsteff,et al.  Comparison of systolic time interval measurement modalities for portable devices , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[20]  G. Cybulski,et al.  Stroke volume and systolic time intervals: Beat-to-beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions , 2004, Medical and Biological Engineering and Computing.

[21]  Guanqun Zhang,et al.  Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure. , 2011, Journal of applied physiology.

[22]  Richard P. Lewis,et al.  A Critical Review of the Systolic Time Intervals , 2005 .

[23]  R. Payne,et al.  Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure. , 2006, Journal of applied physiology.

[24]  Sharon-Lise T. Normand,et al.  An Administrative Claims Measure Suitable for Profiling Hospital Performance on the Basis of 30-Day All-Cause Readmission Rates Among Patients With Heart Failure , 2008, Circulation. Cardiovascular quality and outcomes.

[25]  R. Kelsey,et al.  An evaluation of the ensemble averaged impedance cardiogram. , 1990, Psychophysiology.

[26]  K B Pandolf,et al.  Thermoregulatory and blood responses during exercise at graded hypohydration levels. , 1985, Journal of applied physiology.

[27]  C. Douniama,et al.  Blood pressure tracking capabilities of pulse transit times in different arterial segments: A clinical evaluation , 2009, 2009 36th Annual Computers in Cardiology Conference (CinC).

[28]  J. Fahrenberg,et al.  Methodological guidelines for impedance cardiography. , 1990, Psychophysiology.

[29]  B. Yawn,et al.  Trends in heart failure incidence and survival in a community-based population. , 2004, JAMA.

[30]  Kouhyar Tavakolian,et al.  Ballistocardiography and Seismocardiography: A Review of Recent Advances , 2015, IEEE Journal of Biomedical and Health Informatics.

[31]  John M. Zanetti,et al.  Seismocardiography: a technique for recording precordial acceleration , 1991, [1991] Computer-Based Medical Systems@m_Proceedings of the Fourth Annual IEEE Symposium.

[32]  Omer T. Inan,et al.  A Novel System Identification Technique for Improved Wearable Hemodynamics Assessment , 2015, IEEE Transactions on Biomedical Engineering.

[33]  Sverre Grimnes,et al.  Chapter 11 – History of Bioimpedance and Bioelectricity , 2015 .

[34]  Richard N Channick,et al.  Comparison of impedance cardiography to direct Fick and thermodilution cardiac output determination in pulmonary arterial hypertension. , 2004, Congestive heart failure.

[35]  Steffen Leonhardt,et al.  The IMPACT shirt: textile integrated and portable impedance cardiography , 2014, Physiological measurement.

[36]  A. Weissler,et al.  Systolic Time Intervals in Heart Failure in Man , 1968, Circulation.

[37]  D. Dubin Rapid Interpretation of EKG's , 1977 .

[38]  Willis J. Tompkins,et al.  Cardiac Output Monitoring by Impedance Cardiography During Treadmill Exercise , 1986, IEEE Transactions on Biomedical Engineering.

[39]  A. Torbicki,et al.  A comparison between the automatized impedance cardiography and pulsed-wave Doppler echocardiography methods for measurements of stroke volume (SV) and systolic time intervals (STI). , 1993, Journal of physiology and pharmacology : an official journal of the Polish Physiological Society.

[40]  Syed Anas Imtiaz,et al.  Algorithm for heart rate extraction in a novel wearable acoustic sensor , 2015, Healthcare technology letters.

[41]  Vincent Caille,et al.  Noninvasive Assessment of Cardiac Index in Healthy Volunteers: A Comparison Between Thoracic Impedance Cardiography and Doppler Echocardiography , 2009, Anesthesia and analgesia.

[42]  M. Sawka,et al.  Human tolerance to heat strain during exercise: influence of hydration. , 1992, Journal of applied physiology.

[43]  P. Vries,et al.  Impedance cardiography in cardiac surgery patients: abnormal body weight gives unreliable cardiac output measurements , 1997, Acta anaesthesiologica Scandinavica.

[44]  M. G. Taylor,et al.  Alterations with Age in the Viscoelastic Properties of Human Arterial Walls , 1966, Circulation research.

[45]  J J Sollers,et al.  New ambulatory impedance cardiograph validated against the Minnesota Impedance Cardiograph. , 2001, Psychophysiology.

[46]  Richard M. Wiard,et al.  Robust ballistocardiogram acquisition for home monitoring , 2009, Physiological measurement.

[47]  C. E. Martin,et al.  Autonomic mechanisms in hemodynamic responses to isometric exercise. , 1974, The Journal of clinical investigation.

[48]  W. J. Tompkins,et al.  Motion Artifact from Spot and Band Electrodes During Impedance Cardiography , 1986, IEEE Transactions on Biomedical Engineering.

[49]  P Baiardi,et al.  Multicenter randomised trial on home-based telemanagement to prevent hospital readmission of patients with chronic heart failure. , 2009, International journal of cardiology.

[50]  R M Rangayyan,et al.  Phonocardiogram signal analysis: a review. , 1987, Critical reviews in biomedical engineering.

[51]  P. C. Pandey,et al.  Automatic detection of characteristic points in impedance cardiogram , 2011, 2011 Computing in Cardiology.

[52]  A. Patzak,et al.  Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method , 2011, European Journal of Applied Physiology.

[53]  T. Wibmer,et al.  Pulse transit time and blood pressure during cardiopulmonary exercise tests. , 2011, Physiological research.

[54]  A. Sherwood,et al.  Ambulatory impedance cardiography: a feasibility study. , 1998, Journal of applied physiology.

[55]  George E. Brown,et al.  The cold pressor test for measuring the reactibility of the blood pressure: Data concerning 571 normal and hypertensive subjects , 1936 .

[56]  Kurt C Stange,et al.  Transforming physician practices to patient-centered medical homes: lessons from the national demonstration project. , 2011, Health affairs.

[57]  Shuvo Roy,et al.  Toward Continuous, Noninvasive Assessment of Ventricular Function and Hemodynamics: Wearable Ballistocardiography , 2015, IEEE Journal of Biomedical and Health Informatics.

[58]  D. Auerbach,et al.  Implications of an aging registered nurse workforce. , 2000, JAMA.

[59]  Goutam Saha,et al.  Detection of cardiac abnormality from PCG signal using LMS based least square SVM classifier , 2010, Expert Syst. Appl..

[60]  Xiufeng Yang,et al.  Noninvasive monitoring of blood pressure using optical Ballistocardiography and Photoplethysmograph approaches , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[61]  R. Patterson,et al.  Studies on the effect of controlled volume change on the thoracic electrical impedance , 1978, Medical and Biological Engineering and Computing.

[62]  Shuvo Roy,et al.  A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables , 2016, IEEE Transactions on Biomedical Circuits and Systems.

[63]  L A Geddes,et al.  Pulse transit time as an indicator of arterial blood pressure. , 1981, Psychophysiology.

[64]  Guy Paré,et al.  Review Paper: Systematic Review of Home Telemonitoring for Chronic Diseases: The Evidence Base , 2007, J. Am. Medical Informatics Assoc..

[65]  Liang-Yu Shyu,et al.  The detection of impedance cardiogram characteristic points using wavelet transform , 2004, Comput. Biol. Medicine.

[66]  Y Wang,et al.  Readmission after hospitalization for congestive heart failure among Medicare beneficiaries. , 1997, Archives of internal medicine.

[67]  R. Patterson,et al.  Fundamentals of impedance cardiography , 1989, IEEE Engineering in Medicine and Biology Magazine.

[68]  Charles Sodini,et al.  An Ear-Worn Vital Signs Monitor , 2015, IEEE Transactions on Biomedical Engineering.

[69]  J. Jalonen,et al.  Static-charge-sensitive bed ballistocardiography in cardiovascular monitoring. , 1996, Clinical physiology.

[70]  L. Critchley,et al.  Impedance cardiographyThe impact of new technology , 1998, Anaesthesia.

[71]  M. Borggrefe,et al.  Comparison of Impedance Cardiography and Thermodilution-Derived Measurements of Stroke Volume and Cardiac Output at Rest and During Exercise Testing , 2005, Cardiovascular Drugs and Therapy.

[72]  R. Talley,et al.  Evaluation of the pre-ejection period as an estimate of myocardial contractility in dogs. , 1971, The American journal of cardiology.

[73]  L Mourot,et al.  Measurements of cardiac output during constant exercises: comparison of two non-invasive techniques. , 2004, International journal of sports medicine.

[74]  W. Nichols,et al.  McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles , 1998 .

[75]  C. Young,et al.  Clinical evaluation of continuous noninvasive blood pressure monitoring: Accuracy and tracking capabilities , 1995, Journal of Clinical Monitoring.

[76]  Ross Arena,et al.  Cardiopulmonary exercise testing in the clinical evaluation of patients with heart and lung disease. , 2011, Circulation.

[77]  L. Stevenson,et al.  Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial , 2011, The Lancet.

[78]  A. Varri,et al.  A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[79]  Lara Orlandic,et al.  Unobtrusive Estimation of Cardiac Contractility and Stroke Volume Changes Using Ballistocardiogram Measurements on a High Bandwidth Force Plate , 2016, Sensors.

[80]  Rui Pedro Paiva,et al.  Beat-to-beat systolic time-interval measurement from heart sounds and ECG , 2012, Physiological measurement.

[81]  A. R. Lind,et al.  Aging, isometric strength and endurance, and cardiovascular responses to static effort. , 1975, Journal of applied physiology.

[82]  Claudio Sartori,et al.  Noninvasive and Nonocclusive Blood Pressure Estimation Via a Chest Sensor , 2013, IEEE Transactions on Biomedical Engineering.

[83]  Bozena Kaminska,et al.  Mechanically Flexible Wireless Multisensor Platform for Human Physical Activity and Vitals Monitoring , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[84]  G. G. Belz,et al.  Comparison of impedance cardiography and echocardiography for measurement of stroke volume , 2004, European Journal of Clinical Pharmacology.

[85]  Gerbarg Ds,et al.  Analysis of phonocardiogram by a digital computer. , 1962 .

[86]  K. Flegal,et al.  Prevalence and trends in obesity among US adults, 1999-2008. , 2010, JAMA.

[87]  Gregory T. A. Kovacs,et al.  Rapid Assessment of Cardiac Contractility on a Home Bathroom Scale , 2011, IEEE Transactions on Information Technology in Biomedicine.

[88]  Omer T. Inan,et al.  Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring , 2015, IEEE Transactions on Biomedical Engineering.

[89]  M. Masè,et al.  Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure. , 2011, Journal of electrocardiology.

[90]  G. Fonarow,et al.  Home monitoring for heart failure management. , 2012, Journal of the American College of Cardiology.

[91]  I. Starr,et al.  STUDIES ON THE ESTIMATION OF CARDIAC OUPTUT IN MAN, AND OF ABNORMALITIES IN CARDIAC FUNCTION, FROM THE HEART'S RECOIL AND THE BLOOD'S IMPACTS; THE BALLISTOCARDIOGRAM , 1939 .