The Dynamic Behavior of the Basilica of San Francesco in Assisi Using Simplified Analytical Models

ABSTRACT The Basilica of San Francesco in Assisi endured stronger earthquakes for centuries before 1997 earthquake, which generated the collapse of the two vaults. Experts blame as possible reasons of collapse the damage cumulated from previous earthquakes and/or the retrofitting made to the structure over its lifetime. This article presents the history of the retrofit interventions of the Basilica through the centuries, focusing mainly on the roof, which has been subjected to three major restorations through its life. It is shown using simple analytical models that the cumulative effects of the changes made to the roof of the Basilica affected the structure’s dynamic behavior in a negative manner, increasing the seismic loads on the existing structural members. In particular, the numerical results show that the 1958 roof intervention has stiffened the structure, redistributing the seismic loads on the façade and the transept. This overload might explain the collapse of the two Gothic vaults during 1997 earthquake.

[1]  Gian Paolo Cimellaro,et al.  Reply to “Discussion 2 on ‘Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake’ by G.P. Cimellaro, A.M. Reinhorn and A.De Stefano” by Enzo Cartapati , 2012, Earthquake Engineering and Engineering Vibration.

[2]  Antonella Saisi,et al.  Performance of some repair and strengthening techniques applied to historical stone masonries in seismic areas , 2003 .

[3]  Serena Cattari,et al.  The Case Study of Santa Maria Paganica Church Damaged by 2009 L’Aquila Earthquake , 2010 .

[4]  Michele Betti,et al.  Assessment of seismic resistance of a basilica-type church under earthquake loading: Modelling and analysis , 2008, Adv. Eng. Softw..

[5]  Luís Guerreiro,et al.  Seismic rehabilitation of historical masonry buildings , 2011 .

[6]  Giuseppe Brandonisio,et al.  Damage and performance evaluation of masonry churches in the 2009 L’Aquila earthquake , 2013 .

[7]  Luigi Sorrentino,et al.  Building features and safeguard of church towers in Basilicata (Southern Italy) , 2014 .

[8]  《地震工程与工程振动》编辑委员会,et al.  地震工程与工程振动 = Earthquake engineering and engineering vibration , 1980 .

[9]  Paulo B. Lourenço,et al.  Numerical models for the seismic assessment of an old masonry tower , 2010 .

[10]  Stephen Sartarelli,et al.  The Basilica of St. Francis of Assisi: Glory and Destruction , 1998 .

[11]  Gian Paolo Cimellaro,et al.  Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake , 2011 .

[12]  Bruce Allsopp,et al.  Architecture of Italy , 1964 .

[13]  Giorgio Croci,et al.  Strengthening the Basilica of St Francis of Assisi after the September 1997 Earthquake , 2001 .

[14]  Vincenzo Ciampi Discussion 1 on “Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake” by G.P. Cimellaro, A.M.Reinhorn and A. De Stefano , 2012, Earthquake Engineering and Engineering Vibration.

[15]  Michele Betti,et al.  Modelling and analysis of a Romanesque church under earthquake loading: Assessment of seismic resistance , 2008 .

[16]  Giuseppe Brandonisio,et al.  Seismic safety of basilica churches: analysis of ten case studies , 2008 .

[17]  Sergio Lagomarsino,et al.  Damage assessment of churches after L’Aquila earthquake (2009) , 2012, Bulletin of Earthquake Engineering.

[18]  Sergio Lagomarsino,et al.  Seismic Vulnerability of Ancient Churches: I. Damage Assessment and Emergency Planning , 2004 .

[19]  Claudio Modena,et al.  Seismic Assessment of Complex Historical Buildings: Application to Reggio Emilia Cathedral, Italy , 2008 .

[20]  Comune di Prato Basilica di San Francesco , 2013 .

[21]  Gian Paolo Cimellaro,et al.  Analysis of the failure mechanisms of the basilica of Santa Maria di Collemaggio during 2009 L'Aquila earthquake , 2015 .

[22]  P. Lourenço,et al.  Modeling and vulnerability of historical city centers in seismic areas: a case study in Lisbon , 2004 .

[23]  Gian Paolo Cimellaro,et al.  L'Aquila Earthquake of April 6, 2009 in Italy: Rebuilding a Resilient City to Withstand Multiple Hazards , 2010 .

[24]  Christoph Butenweg,et al.  Modelling methods of historic masonry buildings under seismic excitation , 2006 .

[25]  Elena Mele,et al.  Modelling and analysis of a basilica under earthquake loading , 2003 .

[26]  Paulo B. Lourenço,et al.  Statistical Assessment of Damage to Churches Affected by the 2010–2011 Canterbury (New Zealand) Earthquake Sequence , 2013 .

[27]  Cecilia Gibellini,et al.  La basilica di San Francesco ad Assisi , 2003 .

[28]  Gian Paolo Cimellaro,et al.  Reply to “Discussion 1 on ‘Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake’ by G.P. Cimellaro, A.M. Reinhorn and A.De Stefano” by Vincenzo Ciampi , 2012, Earthquake Engineering and Engineering Vibration.

[29]  Claudio Modena,et al.  Cultural Heritage Buildings and the Abruzzo Earthquake: Performance and Post-Earthquake Actions , 2010 .

[30]  Enzo Cartapati Discussion 2 on “Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake” by G.P. Cimellaro, A.M. Reinhorn and A. De Stefano , 2012, Earthquake Engineering and Engineering Vibration.

[31]  Gianluca Valensise,et al.  CFTI4Med, Catalogue of Strong Earthquakes in Italy (461 B.C.-1997) and Mediterranean Area (760 B.C.-1500) , 2007 .

[32]  Gabriele Milani,et al.  Seismic vulnerability of historical masonry buildings: A case study in Ferrara , 2008 .