On a pathological mathematical model of boiler-turbine generator unit

The research on mathematical model of coordinate control system (CCS) of boiler-turbine generator unit in thermal control field has achieved some significant results. But there are still some important theoretical and conceptual issues. And the correctness of every type of mathematical model has a direct effect on its practical application. Such as Bell- Astrom model, the controlled object described by which is different from the large capability unit. It is pointed out that there are some pathological phenomenon in the model of Bell- Astrom through mathematical analysis and simulation testing. The most important issue is that the model of Bell- Astrom is inconsistent with energy conservation law in steady-state conditions of controlled object described by it. Meanwhile, another practical mathematical model is provided in this paper, which is more in keeping with contemporary large capacity unit.

[1]  Han Zhong-xu,et al.  The Parameter Estimation for a Non-linear Mathematical Model of Boiler-turbine-generator Unit , 2007, 2007 2nd IEEE Conference on Industrial Electronics and Applications.

[2]  Chen Tian-ji,et al.  APPLICATION OF STATE FEEDBACK BASED ON IFO-K△x IN 4×300MW GENERATOR UNIT OF PINGLIANG POWER PLANT , 2004 .

[3]  Qi Xiao-hong ANALYSIS OF LINEAR INCREMENT MATHEMATIC MODEL FOR MULTIVARIATE BOILER-TURBINE COORDINATED CONTROL OBJECT , 2005 .

[4]  L. Jizhen A Simplified Non-Linear Dynamic Model of 500MW Unit , 2004 .

[5]  Karl Eklund,et al.  A Simplified Nonlinear Model of a Drum Boiler-Turbine Unit , 1972 .

[6]  Zeng De DRUM BOILER DYNAMIC MODEL AND LOAD/PRESSURE INCREMENT PREDICT MODEL , 2000 .

[7]  Liu Changliang,et al.  Nonlinear boiler model of 300 MW power unit for system dynamic performance studies , 2001, ISIE 2001. 2001 IEEE International Symposium on Industrial Electronics Proceedings (Cat. No.01TH8570).

[8]  F.P. deMello,et al.  Boiler models for system dynamic performance studies , 1991, IEEE Power Engineering Review.

[9]  Gao Chun-yu Analysis on a Type of Mathematical Model of Thermal Power Plant , 2006 .

[10]  F. P. de Mello,et al.  Boiler models for system dynamic performance studies , 1991 .

[11]  Liu Ji Research on Coordinated Control System of a 500MW Unit Based on Fuzzy Multiple Model , 2003 .

[12]  Li Yi-guo A SIMULATION STUDY ON LOAD MODELING OF A THERMAL POWER UNIT BASED ON WAVELET NEURAL NETWORKS , 2003 .

[13]  Liu Jizhen A PRACTICAL 500MW BOILER DYNAMIC MODEL ANALYSIS , 2003 .

[14]  Chen Lai A STUDY ON FUZZY RULES BASED AND NONLINEAR MODELS FOR THERMAL PROCESSES , 2002 .

[15]  Karl Johan Åström,et al.  Drum-boiler dynamics , 2000, Autom..

[16]  Zeng De-liang A FUZZY MULTI-MODEL CONTROL AND SIMULATION OF COORDINATED CONTROL SYSTEM FOR 500MW BOILER-TURBINE UNIT , 2003 .

[17]  Han Zhong-x Application of state feedback based on state observer in the coordinated control system of 300 MW unit , 2004 .

[18]  Zhao Zheng A SIMPLIFIED NON-LINEAR DYNAMIC MODEL OF 330MW UNIT , 2004 .

[19]  Zhu Ming-cheng Application and Design of Coordinated Control System for No.1&2 600MW Unit of Beilun Power Plant , 2006 .

[20]  Zhang Zhi,et al.  Mixed Boiler-turbine Coordinated Control System Mathematical Model Based on Mechanism Modelling and Parameter Identification , 2006, 2006 1ST IEEE Conference on Industrial Electronics and Applications.

[21]  Kwang Y. Lee,et al.  Boiler-turbine control system design using a genetic algorithm , 1995 .

[22]  Liu Xin-pin Analysis on the Nonlinearity of Load-Pressure Characteristics of a 660MW Unit , 2005 .

[23]  Karl Johan Åström,et al.  Dynamic Models for Boiler-Turbine Alternator Units : Data Logs and Parameter Estimation for a 160 MW Unit , 1987 .