Surgical outcomes after posterior lumbar interbody fusion using traditional trajectory screw fixation or cortical bone trajectory screw fixation: A comparative study between the polyetheretherketone cage and the same shape titanium-coated polyetheretherketone cage
暂无分享,去创建一个
[1] A. Langheinrich,et al. PLIF surgery with titanium-coated PEEK or uncoated PEEK cages: a prospective randomised clinical and radiological study , 2020, European Spine Journal.
[2] Tetsuro Ohba,et al. The Titanium-coated PEEK Cage Maintains Better Bone Fusion With the Endplate Than the PEEK Cage 6 Months After PLIF Surgery: A Multicenter, Prospective, Randomized Study. , 2020, Spine.
[3] T. Kaito,et al. Comparison in the same intervertebral space between titanium-coated and uncoated PEEK cages in lumbar interbody fusion surgery. , 2020, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.
[4] H. Sakaura,et al. Early Fusion Status after Posterior Lumbar Interbody Fusion with Cortical Bone Trajectory Screw Fixation: A Comparison of Titanium-Coated Polyetheretherketone Cages and Carbon Polyetheretherketone Cages , 2018, Asian spine journal.
[5] S. Schreiner,et al. Transforaminal lumbar interbody fusion using polyetheretherketone oblique cages with and without a titanium coating: A RANDOMISED CLINICAL PILOT STUDY , 2017, The bone & joint journal.
[6] T. Nakayama,et al. Vertebral Endplate Cyst as a Predictor of Nonunion After Lumbar Interbody Fusion: Comparison of Titanium and Polyetheretherketone Cages , 2016, Spine.
[7] K. Chiba,et al. Incidence and Risk Factors of Adjacent Cranial Facet Joint Violation Following Pedicle Screw Insertion Using Cortical Bone Trajectory Technique , 2016, Spine.
[8] Hironobu Sakaura,et al. Posterior lumbar interbody fusion with cortical bone trajectory screw fixation versus posterior lumbar interbody fusion using traditional pedicle screw fixation for degenerative lumbar spondylolisthesis: a comparative study. , 2016, Journal of neurosurgery. Spine.
[9] W. Walsh,et al. Radiological and clinical outcomes of novel Ti/PEEK combined spinal fusion cages: a systematic review and preclinical evaluation , 2017, European Spine Journal.
[10] N. Hosogane,et al. Biomechanical evaluation of the fixation strength of lumbar pedicle screws using cortical bone trajectory: a finite element study. , 2015, Journal of neurosurgery. Spine.
[11] W. Walsh,et al. Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface. , 2015, The spine journal : official journal of the North American Spine Society.
[12] A. Fujikawa,et al. Comparison of fusion rates following transforaminal lumbar interbody fusion using polyetheretherketone cages or titanium cages with transpedicular instrumentation , 2014, European Spine Journal.
[13] W. Walsh,et al. Spine Interbody Implants: Material Selection and Modification, Functionalization and Bioactivation of Surfaces to Improve Osseointegration , 2014, Orthopaedic surgery.
[14] N. Crawford,et al. Biomechanics of Lumbar Cortical Screw–Rod Fixation Versus Pedicle Screw–Rod Fixation With and Without Interbody Support , 2013, Spine.
[15] Ho-Joong Kim,et al. The Biomechanical Effect of Pedicle Screws' Insertion Angle and Position on the Superior Adjacent Segment in 1 Segment Lumbar Fusion , 2012, Spine.
[16] G. Gronowicz,et al. The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titanium. , 2008, Biomaterials.
[17] S. Kurtz,et al. PEEK biomaterials in trauma, orthopedic, and spinal implants. , 2007, Biomaterials.
[18] Tomio Yamamoto,et al. Clinical and Radiological Results of PLIF for Degenerative Spondylolisthesis , 1998 .
[19] K. Yone,et al. Indication of Fusion for Lumbar Spinal Stenosis in Elderly Patients and Its Significance , 1996, Spine.