Inductance-simulating control for DFIG-based wind turbine to ride-through grid faults

For doubly fed induction generator (DFIG)-based wind turbine (WT), large electromotive force will be induced in the rotor circuit under grid faults, and the rotor side of DFIG is prone to suffering from overcurrent and overvoltage. To mitigate this problem, an inductance-simulating control strategy is proposed to enhance its low-voltage ride through (LVRT) capability. In this method, the rotor side converter (RSC) is controlled to simulating as an inductance. Furthermore, under proper inductance value, both the required rotor voltage and post-fault rotor current can be reduced within the permissible range. In addition, the electromagnetic torque ripple can be effectively eliminated. Finally, the simulation and experimental results clearly demonstrate the effectiveness of the proposed method.

[1]  Kavitha Busi,et al.  Fault Ride-Through of a DFIG Wind Turbine Using a Dynamic Voltage Restorer during Symmetrical and Asymmetrical Grid Faults , 2013 .

[2]  Giri Venkataramanan,et al.  Unbalanced Voltage Sag Ride-Through of a Doubly Fed Induction Generator Wind Turbine With Series Grid-Side Converter , 2009 .

[3]  Geng Yang,et al.  An LVRT Control Strategy Based on Flux Linkage Tracking for DFIG-Based WECS , 2013, IEEE Transactions on Industrial Electronics.

[4]  Zhen Xie,et al.  Virtual inductance self-demagnetization based LVRT control strategy for doubly fed WTs , 2015, 2015 IEEE Applied Power Electronics Conference and Exposition (APEC).

[5]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[6]  Li Ran,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006, IEEE Transactions on Energy Conversion.

[7]  Yong Kang,et al.  An Improved Low-Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator During Grid Faults , 2011, IEEE Transactions on Power Electronics.

[8]  P. Sanchis,et al.  Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips , 2007, IEEE Transactions on Energy Conversion.

[9]  Yang Wang,et al.  Grid-fault tolerant operation of DFIG wind turbine generator using a passive resistance network , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[10]  F. Blaabjerg,et al.  Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults , 2010, IEEE Transactions on Power Electronics.

[11]  Yang Wang,et al.  Grid-Fault Tolerant Operation of a DFIG Wind Turbine Generator Using a Passive Resistance Network , 2011, IEEE Transactions on Power Electronics.

[12]  D. F. Howard,et al.  Feedforward Transient Compensation Control for DFIG Wind Turbines During Both Balanced and Unbalanced Grid Disturbances , 2013, IEEE Transactions on Industry Applications.

[13]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.