Comparison of two methods for estimating respiratory waveforms from videos without contact

Among all the vital signs and physiological parameters, the respiratory rate (fR) is still considered the neglected vital sign. In the clinical scenario, occupational scenario and during sport and activities different methods can be used to record the respiratory waveform and thus the fR.In this paper, we investigated the performances of two different methods for the non-contact monitoring of respiratory waveform by using RGB video signal acquired from a single built-in high-definition webcam. Two different methods have been tested: the first based on the intensity change of video pixels and the second on the extraction of the optical flow from the video sequence.The results obtained so far from eight subjects in the time and frequency domain reveal that optical flow method is better performing than its counterpart. The maximum percentage error for the optical flow method in the frequency domain to calculate the breathing rate stands at less than 3% for all the subjects investigated by far. Likewise, in the time domain, the maximum mean absolute error (MAE) reported for the optical flow method stands at less than 1% in all the subjects.

[1]  Daniel McDuff,et al.  Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam , 2011, IEEE Transactions on Biomedical Engineering.

[2]  L. Tarassenko,et al.  Continuous non-contact vital sign monitoring in neonatal intensive care unit , 2014, Healthcare technology letters.

[3]  P. Welch The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms , 1967 .

[4]  F. Taffoni,et al.  Validation of a Wearable Device and an Algorithm for Respiratory Monitoring During Exercise , 2019, IEEE Sensors Journal.

[5]  Gerard de Haan,et al.  Video-based respiration monitoring with automatic region of interest detection , 2016, Physiological measurement.

[6]  Sergio Silvestri,et al.  Measurement system based on RBG camera signal for contactless breathing pattern and respiratory rate monitoring , 2018, 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[7]  M. Sackner,et al.  Validation of respiratory inductive plethysmography using different calibration procedures. , 2015, The American review of respiratory disease.

[8]  B. Hök,et al.  Critical review of non-invasive respiratory monitoring in medical care , 2003, Medical and Biological Engineering and Computing.

[9]  Sergio Silvestri,et al.  Contact-Based Methods for Measuring Respiratory Rate , 2019, Sensors.

[10]  A. Cheng,et al.  Respiratory rate: the neglected vital sign , 2008, The Medical journal of Australia.

[11]  Akinori Ueno,et al.  Non-Contact Simultaneous Measurements of Electrocardiogram and Respiratory Movements Using Capacitive Sheet Electrodes , 2017 .

[12]  Radu Horaud,et al.  Time-of-Flight Cameras , 2012, SpringerBriefs in Computer Science.

[13]  L. Tarassenko,et al.  Non-contact video-based vital sign monitoring using ambient light and auto-regressive models , 2014, Physiological measurement.

[14]  Radu Horaud,et al.  Time-of-Flight Cameras: Principles, Methods and Applications , 2012 .

[15]  Cheong Boon Soh,et al.  Wireless Sensing of Human Respiratory Parameters by Low-Power Ultrawideband Impulse Radio Radar , 2011, IEEE Transactions on Instrumentation and Measurement.

[16]  Louis Passfield,et al.  Respiratory Frequency during Exercise: The Neglected Physiological Measure , 2017, Front. Physiol..

[17]  Mariusz Krej,et al.  Fiber Bragg Grating Strain Sensor Incorporated to Monitor Patient Vital Signs During MRI , 2013, IEEE Sensors Journal.

[18]  Sergio Silvestri,et al.  Contactless Monitoring of Breathing Patterns and Respiratory Rate at the Pit of the Neck: A Single Camera Approach , 2018, J. Sensors.

[19]  B. Porat,et al.  Digital Spectral Analysis with Applications. , 1988 .

[20]  Ying-Wen Bai,et al.  Design and implementation of an embedded monitor system for detection of a patient's breath by double Webcams , 2010, 2010 IEEE International Workshop on Medical Measurements and Applications.

[21]  Lorenzo Scalise,et al.  Laser measurement of respiration activity in preterm infants: Monitoring of peculiar events , 2012 .