Field performance of thin wall foundations

The feasibility of building residential basement foundation walls of unreinforced concrete thinner than the conventional 200 mm thick wall is investigated. An optimum thickness of 150 mm was determined for an unreinforced 2400 mm high foundation wall based on the use of equivalent fluid pressures with sand and gravel backfill material. For walls backfilled with other than clean sand and gravel, or with a submerged condition, it was found that the theoretical maximum backfill heights for both 150 and 200 mm walls are substantially less than those presently specified by the Alberta Building Code. The primary purpose of the study described in this paper was to test under actual field conditions the performance of a 150 mm unreinforced concrete wall under varying lateral loads imposed by different soil types, and to compare measured and calculated lateral loads with the equivalent fluid pressure specified as a criterion in the Alberta Building Code. The lateral earth pressures resulting from the backfilling o...