Axial resolution limit of a fiber-optic fluorescence probe.

We examine the limit of spatial resolution achievable when a sine optical fiber is used for excitation and collection of fluorescence from a bulk specimen. We calculate the probability of detecting a fluorescent particle as a function of its position relative to the fiber face, using excitation wavelength lambda, radius a, numerical aperture N.A., and the particle's fluorescence and absorbance spectra. Treating Rhodamine B as a model fluorescent analyte and using appropriate fiber parameters, we show that the maximum axial resolution (defined as the axial distance in a homogenous solution within which 50% of the detected signal originates) achievable is approximately 10 microm. We experimentally measured the axial resolution for a 500-microM aqueous solution of Rhodamine B with lambda = 543 nm, a = 1.31 microm, and a N.A. of 0.16 and found good qualitative agreement with the calculation.

[1]  F. Ligler,et al.  Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber-optic biosensor. , 1996, Analytical biochemistry.

[2]  María Marazuela,et al.  Fiber-optic biosensors – an overview , 2002, Analytical and bioanalytical chemistry.

[3]  S. Maiti,et al.  Quantitative measurement of serotonin synthesis and sequestration in individual live neuronal cells , 2005, Journal of neurochemistry.

[4]  W. Webb,et al.  Fluorescence correlation spectroscopy: diagnostics for sparse molecules. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[5]  Dietrich Marcuse,et al.  Gaussian approximation of the fundamental modes of graded-index fibers , 1978 .

[6]  W. Webb,et al.  Dynamics of fluorescence fluctuations in green fluorescent protein observed by fluorescence correlation spectroscopy. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[7]  J. Pawley,et al.  Handbook of Biological Confocal Microscopy , 1990, Springer US.

[8]  B Messerschmidt,et al.  Endoscope-compatible confocal microscope using a gradient index-lens system , 2001 .

[9]  C Ziegler,et al.  Cell-based biosensors , 2000, Fresenius' journal of analytical chemistry.

[10]  E. Betzig,et al.  Near-Field Optics: Microscopy, Spectroscopy, and Surface Modification Beyond the Diffraction Limit , 1992, Science.

[11]  S. Maiti,et al.  Measuring diffusion in cell membranes by fluorescence correlation spectroscopy. , 2002, Methods.

[12]  M. Descour,et al.  Design of a high-numerical-aperture miniature microscope objective for an endoscopic fiber confocal reflectance microscope. , 2002, Applied optics.

[13]  Jannick P Rolland,et al.  Estimation of longitudinal resolution in optical coherence imaging. , 2002, Applied optics.

[14]  J. Fujimoto,et al.  In vivo endoscopic optical biopsy with optical coherence tomography. , 1997, Science.

[15]  R Richards-Kortum,et al.  Fiber confocal reflectance microscope (FCRM) for in-vivo imaging. , 2001, Optics express.

[16]  W. Webb,et al.  Thermodynamic Fluctuations in a Reacting System-Measurement by Fluorescence Correlation Spectroscopy , 1972 .