A beat-to-beat P wave analysis in healthy population

Aim of this study is to explore and quantify possible beat-to-beat variations in P wave characteristics. Two-minute X-lead ECG recordings were analyzed. Data were obtained from Physionet database. Each P wave was fitted by a Gaussian function whose parameter variations were investigated over two minutes window. The normalized root mean squared error (NRMSE) between each P wave and its fitting was computed. To evaluate the variability of the estimated parameters, the coefficient of variation (CV) was computed. The proposed model well fitted the P waves, being the mean NRMSE 0.047 ± 0.030 mV (range 0.012 − 0.140 mV). A variability was found in all patients for both the parameters A and s, reflecting P waves amplitude and duration, respectively, being CVA 0.087 ± 0.050 mV (range 0.032 − 0.253 mV) and CVσ 0.093 ± 0.053 (range 0.028 − 0.27). These preliminary results could be used as a starting point for future beat-to-beat P wave analysis in patients with atrial conduction pathologies.

[1]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[2]  J. Steinberg,et al.  The signal-averaged P wave duration: a rapid and noninvasive marker of risk of atrial fibrillation. , 1993, Journal of the American College of Cardiology.

[3]  P Caminal,et al.  Automatic detection of wave boundaries in multilead ECG signals: validation with the CSE database. , 1994, Computers and biomedical research, an international journal.

[4]  Ioanna Chouvarda,et al.  Can P Wave Wavelet Analysis Predict Atrial Fibrillation After Coronary Artery Bypass Grafting? , 2003, Pacing and clinical electrophysiology : PACE.

[5]  Manolis I. A. Lourakis,et al.  Is Levenberg-Marquardt the most efficient optimization algorithm for implementing bundle adjustment? , 2005, Tenth IEEE International Conference on Computer Vision (ICCV'05) Volume 1.

[6]  Alberto Herreros,et al.  Age-related changes in P wave morphology in healthy subjects , 2007, BMC cardiovascular disorders.

[7]  Jonas Carlson,et al.  Signal-averaged P wave analysis for delineation of interatrial conduction – Further validation of the method , 2007, BMC cardiovascular disorders.

[8]  Giovanni Calcagnini,et al.  P-Wave Morphology Assessment by a Gaussian Functions-Based Model in Atrial Fibrillation Patients , 2007, IEEE Transactions on Biomedical Engineering.

[9]  Jared W. Magnani,et al.  Advances in Arrhythmia and Electrophysiology P Wave Indices Current Status and Future Directions in Epidemiology, Clinical, and Research Applications , 2009 .

[10]  Rolf Johansson,et al.  Analysis of changes in the beat-to-beat P-wave morphology using clustering techniques , 2009, Biomed. Signal Process. Control..

[11]  Hideki Hayashi,et al.  P wave and the development of atrial fibrillation. , 2010, Heart rhythm.