An Experimental Study on the Effect of the Anisotropic Regions in a Realistically Shaped Torso Phantom

Determination of electrically active regions in the human body by observing generated bioelectric and/or biomagnetic signals is known as source reconstruction. In the reconstruction process, it is assumed that the volume conductor consists of isotropic compartments and homogeneous tissue bioelectric parameters but this assumption introduces errors when the tissue of interest is anisotropic. The aim of this study was to investigate changes in the measured signal strengths and the estimated positions and orientations of current dipoles in a realistically shaped torso phantom having a heart region built from single guar gum skeins. Electric data were recorded with 60 electrodes on the front of the chest and 195 sensors measured the magnetic field 2 cm above the chest. The artificial rotating dipoles were located underneath the anisotropic skeins distant from the sensors. It was found that the signal strengths and estimated dipole orientations were influenced by the anisotropy while the estimated dipole positions were not significantly influenced. The signal strength was reduced between 17% and 43% for the different dipole positions when comparing the parallel alignment of dipole orientation and anisotropy direction with the orthogonal alignment. The largest error in the estimation of dipole orientation was 42 degrees. The observed changes in the magnetic fields and electric potentials can be explained by the fact that the anisotropic skeins force the current along its direction. We conclude that taking into account anisotropic structures in the volume conductor might improve signal analysis as well as source strength and orientation estimations for bioelectric and biomagnetic investigations.

[1]  P. Nicholson,et al.  Specific impedance of cerebral white matter. , 1965, Experimental neurology.

[2]  Charles Polk,et al.  CRC Handbook of Biological Effects of Electromagnetic Fields , 1986 .

[3]  Onno W. Weier,et al.  On the numerical accuracy of the boundary element method (EEG application) , 1989, IEEE Transactions on Biomedical Engineering.

[4]  A. McCulloch,et al.  Passive material properties of intact ventricular myocardium determined from a cylindrical model. , 1991, Journal of biomechanical engineering.

[5]  Y Rudy,et al.  A model study of volume conductor effects on endocardial and intracavitary potentials. , 1992, Circulation research.

[6]  H. Bruder,et al.  The influence of inhomogeneous volume conductor models on the ECG and the MCG. , 1994, Physics in medicine and biology.

[7]  C. Nicholson,et al.  Origin of the apparent tissue conductivity in the molecular and granular layers of the in vitro turtle cerebellum and the interpretation of current source-density analysis. , 1994, Journal of neurophysiology.

[8]  Daming Wei,et al.  Comparative simulation of excitation and body surface electrocardiogram with isotropic and anisotropic computer heart models , 1995, IEEE Transactions on Biomedical Engineering.

[9]  G. Tognola,et al.  A volume-conduction analysis of magnetic stimulation of peripheral nerves , 1996, IEEE Transactions on Biomedical Engineering.

[10]  Sylvain Baillet,et al.  Influence of skull anisotropy for the forward and inverse problem in EEG: Simulation studies using FEM on realistic head models , 1998, Human brain mapping.

[11]  M. Peters,et al.  Volume conduction effects in EEG and MEG. , 1998, Electroencephalography and clinical neurophysiology.

[12]  M Wagner,et al.  Improving source reconstructions by combining bioelectric and biomagnetic data. , 1998, Electroencephalography and clinical neurophysiology.

[13]  U Leder,et al.  Source localization in an inhomogeneous physical thorax phantom. , 1999, Physics in medicine and biology.

[14]  Richard M. Leahy,et al.  Electromagnetic brain mapping , 2001, IEEE Signal Process. Mag..

[15]  Richard M. Leahy,et al.  Electromagnetic brain mapping - IEEE Signal Processing Magazine , 2001 .

[16]  J. Haueisen,et al.  The Influence of Brain Tissue Anisotropy on Human EEG and MEG , 2002, NeuroImage.

[17]  Matthias Dümpelmann,et al.  Influence of realistic skull and white matter anisotropy on the inverse problem in EEG/MEG-source localization , 2002 .

[18]  M. Murray,et al.  EEG source imaging , 2004, Clinical Neurophysiology.

[19]  R. Leahy,et al.  Mapping human brain function with MEG and EEG: methods and validation , 2004, NeuroImage.

[20]  C. E. Acar,et al.  Sensitivity of EEG and MEG measurements to tissue conductivity , 2004, Physics in medicine and biology.

[21]  Xavier Tricoche,et al.  Influence of local and remote white matter conductivity anisotropy for a thalamic source on EEG/MEG field and return current computation , 2005 .

[22]  B. He,et al.  Effects of cardiac anisotropy on three-dimensional ECG localization inverse solutions : a model study , 2005 .

[23]  Jens Haueisen,et al.  Vortex Shaped Current Sources in a Physical Torso Phantom , 2005, Annals of Biomedical Engineering.

[24]  Thomas R. Knösche,et al.  Influence of anisotropic conductivity of the white matter tissue on EEG source reconstruction - a FEM simulation study , 2005 .

[25]  Peter M. van Dam,et al.  Volume conductor effects involved in the genesis of the P wave. , 2005 .

[26]  H. Buchner,et al.  The influence of skull-conductivity misspecification on inverse source localization in realistically shaped finite element head models , 2005, Brain Topography.

[27]  Jens Haueisen,et al.  Passive vortex currents in magneto- and electrocardiography: comparison of magnetic and electric signal strengths , 2006, Physics in medicine and biology.

[28]  F. Zanow,et al.  Individually shaped volume conductor models of the head in EEG source localisation , 1995, Medical and Biological Engineering and Computing.

[29]  Thomas R. Knösche,et al.  Influence of anisotropic conductivity on EEG source reconstruction: investigations in a rabbit model , 2006, IEEE Transactions on Biomedical Engineering.

[30]  Xavier Tricoche,et al.  Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: A simulation and visualization study using high-resolution finite element modeling , 2006, NeuroImage.

[31]  I. Lemahieu,et al.  Dipole location errors in electroencephalogram source analysis due to volume conductor model errors , 2000, Medical and Biological Engineering and Computing.

[32]  R. Plonsey,et al.  Extracellular (volume conductor) effect on adjoining cardiac muscle electrophysiology , 1988, Medical and Biological Engineering and Computing.

[33]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[34]  Bernhard Pfeifer,et al.  Cardiac anisotropy: is it negligible regarding noninvasive activation time imaging? , 2006, IEEE Transactions on Biomedical Engineering.

[35]  R. Gulrajani,et al.  Effects of rotational myocardial anisotropy in forward potential computations with equivalent heart dipoles , 1997, Annals of Biomedical Engineering.

[36]  Jens Haueisen,et al.  Influence of anisotropic compartments on magnetic field and electric potential distributions generated by artificial current dipoles inside a torso phantom , 2008, Physics in medicine and biology.