In vitro and in vivo measurement for biological applications using micromachined probe

We developed a small-sized micromachined probe for the measurement of biological properties using microelectromechanical systems (MEMS) technology. We also experimentally showed the suitability of the micromachined probe for biological applications through in vivo, as well as in vitro measurements of various types of tissue. We measured the permittivities of 0.9% saline and the muscle and fat of pork using the micromachined probe after liquid calibration. The measured permittivities of 0.9% saline and pork agreed well with both the expected values of the Cole-Cole equation along with the measured values obtained through the use of a 1-mm-diameter open-ended coaxial probe. We also performed in vivo measurements of breast cancer tissue implanted in an athymic nude mouse to show the suitability of the small-sized micromachined probe for practical biological applications. Through the obtained data, the capability of the micromachined probe of distinguishing different tissue types from one another was shown. The actual aperture size of the micromachined probe is only 240 /spl mu/m /spl times/ 70 /spl mu/m and, therefore, we can extract the biological information from very small biological tissues and drastically decrease the invasiveness of this method through the implementation of the small probe created through the use of MEMS technology.

[1]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[2]  Srinivas Sridhar,et al.  Technique for measuring the frequency‐dependent complex dielectric constants of liquids up to 20 GHz , 1989 .

[3]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[4]  Done-Sik Yoo,et al.  The dielectric properties of cancerous tissues in a nude mouse xenograft model , 2004, Bioelectromagnetics.

[5]  E. C. Burdette,et al.  Preliminary In-Vivo Probe Measurements of Electrical Properties of Tumors in Mice , 1977, 1977 IEEE MTT-S International Microwave Symposium Digest.

[6]  Maria A. Stuchly,et al.  Measurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part I , 1982 .

[7]  M. Okoniewski,et al.  Sensing volume of open-ended coaxial probes for dielectric characterization of breast tissue at microwave frequencies , 2003, IEEE Antennas and Propagation Society International Symposium. Digest. Held in conjunction with: USNC/CNC/URSI North American Radio Sci. Meeting (Cat. No.03CH37450).

[8]  S. S. Stuchly,et al.  Permittivity measurements using open-ended sensors and reference liquid calibration-an uncertainty analysis , 1992 .

[9]  S. Sridhar,et al.  Radiation-corrected open-ended coax line technique for dielectric measurements of liquids up to 20 GHz , 1991 .

[10]  T. W. Athey,et al.  Measurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part II - Experimental Results , 1982 .

[11]  H. P. Schwan,et al.  Interaction of Microwave and Radio Frequency Radiation with Biological Systems , 1971 .

[12]  I. Huynen,et al.  Measurements of complex permittivity of biological and organic liquids up to 110 GHz , 1997, 1997 IEEE MTT-S International Microwave Symposium Digest.

[13]  E. C. Burdette,et al.  In Vivo Probe Measurement Technique for Determining Dielectric Properties at VHF through Microwave Frequencies , 1980 .

[14]  Georg Neubauer,et al.  Dielectric properties of human brain tissue measured less than 10 h postmortem at frequencies from 800 to 2450 MHz , 2003, Bioelectromagnetics.