Fault detection and isolation in transient states using principal component analysis

Abstract This paper proposes the use of principal component analysis (PCA) for process monitoring and fault detection and isolation in processes with several operation modes and long transient states and start-ups. The principal aspects of the PCA approach and the necessary transformations for dealing with this type of processes are presented. In this paper a classical PCA model is used for each steady state of the process and a modification of a batch PCA approach is applied to the transient states of the continuous process. So, in this last case, the PCA model is performed over a three way matrix arranged with the values of the measured variables of several past transitions with a nominal behaviour. This approach presents some problems, such as the unfolding, alignment and imputation. The methods proposed to deal with these problems are explained in detail and compared in order to design a fault detection and isolation method. Two examples are considered to perform the tasks explained. In both cases good results are obtained.

[1]  M. J. Fuente,et al.  Fault diagnosis in a plant using Fisher discriminant analysis , 2008, 2008 16th Mediterranean Conference on Control and Automation.

[2]  Theodora Kourti,et al.  Multivariate SPC Methods for Process and Product Monitoring , 1996 .

[3]  Theodora Kourti,et al.  Abnormal situation detection, three-way data and projection methods; robust data archiving and modeling for industrial applications , 2003, Annu. Rev. Control..

[4]  Alberto Ferrer,et al.  Batch process diagnosis: PLS with variable selection versus block-wise PCR , 2004 .

[5]  Alberto Ferrer,et al.  Real-time synchronization of batch trajectories for on-line multivariate statistical process control using Dynamic Time Warping , 2011 .

[6]  Julio E. Normey-Rico,et al.  Distributed continuous process simulation: An industrial case study , 2008, Comput. Chem. Eng..

[7]  B. Kowalski,et al.  Partial least-squares regression: a tutorial , 1986 .

[8]  Weihua Li,et al.  Recursive PCA for adaptive process monitoring , 1999 .

[9]  R Bro,et al.  Cross-validation of component models: A critical look at current methods , 2008, Analytical and bioanalytical chemistry.

[10]  Alberto Ferrer,et al.  Framework for regression‐based missing data imputation methods in on‐line MSPC , 2005 .

[11]  Theodora Kourti,et al.  Multivariate SPC for startups and grade transitions , 2002 .

[12]  Paul Geladi,et al.  Principal Component Analysis , 1987, Comprehensive Chemometrics.

[13]  A. Ferrer,et al.  Dealing with missing data in MSPC: several methods, different interpretations, some examples , 2002 .

[14]  Yale Zhang,et al.  Online monitoring of steel casting processes using multivariate statistical technologies: From continuous to transitional operations☆ , 2006 .

[15]  Age K. Smilde,et al.  Performance assessment and improvement of control charts for statistical batch process monitoring , 2006 .

[16]  W. Krzanowski,et al.  Cross-Validatory Choice of the Number of Components From a Principal Component Analysis , 1982 .

[17]  Theodora Kourti,et al.  Multivariate dynamic data modeling for analysis and statistical process control of batch processes, start‐ups and grade transitions , 2003 .

[18]  P. A. Taylor,et al.  Synchronization of batch trajectories using dynamic time warping , 1998 .

[19]  Raghunathan Rengaswamy,et al.  A review of process fault detection and diagnosis: Part I: Quantitative model-based methods , 2003, Comput. Chem. Eng..

[20]  Yale Zhang,et al.  Integrated monitoring solution to start-up and run-time operations for continuous casting , 2003 .

[21]  Chonghun Han,et al.  Real-time monitoring for a process with multiple operating modes , 1998 .

[22]  Alberto Ferrer,et al.  Multivariate Statistical Process Control Based on Principal Component Analysis (MSPC-PCA): Some Reflections and a Case Study in an Autobody Assembly Process , 2007 .

[23]  Julio E. Normey-Rico,et al.  OPC based distributed real time simulation of complex continuous processes , 2005, Simul. Model. Pract. Theory.

[24]  Fuli Wang,et al.  Stage-based soft-transition multiple PCA modeling and on-line monitoring strategy for batch processes , 2007 .

[25]  L. Jun,et al.  Comparative study of PCA approaches in process monitoring and fault detection , 2004, 30th Annual Conference of IEEE Industrial Electronics Society, 2004. IECON 2004.

[26]  José Camacho Páez New methods based on the projection to latent structures for monitoring, prediction and optimization of batch processes , 2007 .

[27]  Raghunathan Rengaswamy,et al.  A review of process fault detection and diagnosis: Part II: Qualitative models and search strategies , 2003, Comput. Chem. Eng..

[28]  Jesús Picó,et al.  On-line monitoring of batch processes based on PCA: does the modelling structure matter? [corrected]. , 2009, Analytica chimica acta.

[29]  M. J. Fuente,et al.  Estudio comparativo de técnicas de detección de fallos basadas en el Análisis de Componentes Principales (PCA) , 2011 .

[30]  M. Kramer Nonlinear principal component analysis using autoassociative neural networks , 1991 .

[31]  A. J. Morris,et al.  Application of exponentially weighted principal component analysis for the monitoring of a polymer film manufacturing process , 2003 .

[32]  Raghunathan Rengaswamy,et al.  A review of process fault detection and diagnosis: Part III: Process history based methods , 2003, Comput. Chem. Eng..

[33]  B Lennox,et al.  Process monitoring of an industrial fed-batch fermentation. , 2001, Biotechnology and bioengineering.

[34]  John F. MacGregor,et al.  Multivariate SPC charts for monitoring batch processes , 1995 .

[35]  H. Kiers Towards a standardized notation and terminology in multiway analysis , 2000 .

[36]  Christos Georgakis,et al.  Disturbance detection and isolation by dynamic principal component analysis , 1995 .

[37]  J. E. Jackson A User's Guide to Principal Components , 1991 .

[38]  Svante Wold,et al.  Modelling and diagnostics of batch processes and analogous kinetic experiments , 1998 .