Numerical comparison between energy and comfort performances of radiant heating and cooling systems vs . air systems

A comparison between energy performance, simulated by means of the EnergyPlus building simulation program, of two air systems (all air and fan coil) and radiant heating and cooling floors/ceilings is developed in this work for various European climates (Milan, Frankfurt, London, Madrid, Athens, Helsinki, and Moscow) and carried out on a reference building selected from among U.S. Department of Energy commercial building new construction benchmarks. The comparison is focused on the analysis of energy sources and CO2 emissions at equivalent thermal comfort quality levels in the various cases. The adoption of a radiant system, and of an appropriate primary energy system, always results in a reduction of energy sources exploited, of costs for energy wares purchased, and of carbon dioxide emissions. The greatest reductions can be achieved in climates where the energy demand for cooling is greater than the energy demand for heating. The article also focuses on the discussion of the procedure to be adopted when a comparison between air systems and radiant systems is implemented.

[1]  Francesco Causone,et al.  Solar radiation and cooling load calculation for radiant systems: Definition and evaluation of the Direct Solar Load , 2010 .

[2]  Stanley A. Mumma,et al.  Ceiling Radiant Cooling Panels as a Viable Distributed Parallel Sensible Cooling Technology Integrated with Dedicated Outdoor Air Systems , 2001 .

[3]  C. R. MacCluer,et al.  Comparative study of proportional flux-modulation and various types of temperature-modulation approaches for radiant floor-heating system control , 1994 .

[4]  Bjarne W. Olesen,et al.  Low temperature heating and high temperature cooling , 2009 .

[5]  Richard D. Watson,et al.  Radiant Heating and Cooling Handbook , 2008 .

[6]  B. Olesen Control of slab heating and cooling systems studied by dynamic computer simulations. , 2002 .

[7]  Helmut E. Feustel,et al.  Hydronic radiant cooling — preliminary assessment☆ , 1995 .

[8]  Bjarne W. Olesen,et al.  Radiant Floor Heating In Theory and Practice , 2002 .

[9]  J.-W. Jeong,et al.  Designing a Dedicated Outdoor Air System With Ceiling Radiant Cooling Panels , 2006 .

[10]  Bjarne W. Olesen,et al.  History of Radiant Heating & Cooling Systems: Part 1 , 2010 .

[11]  Bjarne W. Olesen,et al.  CONTROL OF FLOOR HEATING AND COOLING SYSTEMS , 2001 .

[12]  A. Hwang [Thermal comfort]. , 1990, Taehan kanho. The Korean nurse.

[13]  Jae-Weon Jeong,et al.  Energy Conservation Benefits of a Dedicated Outdoor Air System with Parallel Sensible Cooling by Ceiling Radiant Panels , 2003 .

[14]  Richard Karl Strand,et al.  Modeling Radiant Systems in an Integrated Heat Balance Based Energy Simulation Program , 2002 .