In Vivo Determination of Hepatic Stiffness Using Steady-State Free Precession Magnetic Resonance Elastography

Objective:The objective of this study was to introduce an magnetic resonance elastography (MRE) protocol based on fractional motion encoding and planar wave acquisition for rapid measurements of in vivo human liver stiffness. Materials and Methods:Vibrations of a remote actuator membrane were fed by a rigid rod to the patient's surface beneath the right costal arch resulting in axial shear deflections of the liver. Data acquisition was performed using a balanced steady-state free precession (bSSFP) sequence incorporating oscillating gradients for motion sensitization. Tissue vibrations of frequency fv = 51 Hz were tuned by twice the sequence repetition time (1/fv = 2TR). Twenty axial images acquired by time-resolved through-plane wave encoding were used for planar elasticity reconstruction. The MRE data acquisition was achieved within 4 breathholds of 17 seconds each. The method was applied to 12 healthy volunteers and 2 patients with diffuse liver disease (fibrosis grade 3). Results:MRE data acquisition was successful in all volunteers and patients. The elastic moduli were measured with values between 1.99 ± 0.16 and 5.77 ± 0.88 kPa. Follow-up studies demonstrated the reproducibility of the method and revealed a difference of 0.74 ± 0.47 kPa (P < 0.05) between the hepatic stiffness of 2 healthy male volunteers. Conclusion:bSSFP combined with fractional MRE enables rapid measurement of liver stiffness in vivo. The used actuation principle supports a 2-dimensional analysis of the strain wave field captured by axial wave images. The measured data indicate individual variations of hepatic stiffness in healthy volunteers.

[1]  Peter Neuhaus,et al.  Living donor right liver lobes: preoperative CT volumetric measurement for calculation of intraoperative weight and volume. , 2006, Radiology.

[2]  S. Friedman,et al.  Liver fibrosis -- from bench to bedside. , 2003, Journal of hepatology.

[3]  K D Paulsen,et al.  Magnetic resonance elastography using 3D gradient echo measurements of steady-state motion. , 2001, Medical physics.

[4]  R. Soloway,et al.  Observer error and sampling variability tested in evaluation of hepatitis and cirrhosis by liver biopsy , 1971, The American Journal of Digestive Diseases.

[5]  Christos Christidis,et al.  Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis C , 2005, Hepatology.

[6]  Y Yamakoshi,et al.  Clinical evaluation of sonoelasticity measurement in liver using ultrasonic imaging of internal forced low-frequency vibration. , 2000, Ultrasound in medicine & biology.

[7]  S Maderwald,et al.  Balanced alternating steady‐state elastography , 2006, Magnetic resonance in medicine.

[8]  Stanislav Emelianov,et al.  Biophysical Bases of Elasticity Imaging , 1995 .

[9]  S. Timoshenko,et al.  Theory of elasticity , 1975 .

[10]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[11]  Alexander F. Kolen,et al.  Characterization of cardiovascular liver motion for the eventual application of elasticity imaging to the liver in vivo. , 2004, Physics in medicine and biology.

[12]  E. Mezey,et al.  Sampling variability on percutaneous liver biopsy. , 1979, Archives of internal medicine.

[13]  B. V. Van Beers,et al.  Liver fibrosis: non‐invasive assessment with MR elastography , 2006, NMR in biomedicine.

[14]  P. Carson,et al.  Magnetic-resonance imaging techniques for detection of elasticity variation. , 1995, Medical physics.

[15]  Y. Fung,et al.  Biomechanics: Mechanical Properties of Living Tissues , 1981 .

[16]  J.M.A. Lenihan,et al.  Biomechanics — Mechanical properties of living tissue , 1982 .

[17]  Jürgen Braun,et al.  Shear wave group velocity inversion in MR elastography of human skeletal muscle , 2006, Magnetic resonance in medicine.

[18]  M Fink,et al.  Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography , 2005, Magnetic resonance in medicine.

[19]  G Crosta Mathematical Review: MR2044619 (2005b:74051) Barbone, Paul E.; Gokhale, Nachiket H. Elastic modulus imaging: on the uniqueness and nonuniqueness of the elastography inverse problem in two dimensions , 2005 .

[20]  R L Ehman,et al.  Complex‐valued stiffness reconstruction for magnetic resonance elastography by algebraic inversion of the differential equation , 2001, Magnetic resonance in medicine.

[21]  M. Fink,et al.  Observation of shock transverse waves in elastic media. , 2003, Physical review letters.

[22]  Real-Time Monitoring of Shear Wave Traveling in Liver Tissue In Vivo , 2004 .

[23]  P. Rossman,et al.  In Vivo MR Elastography of the Liver: Preliminary Results , 2005 .

[24]  D B Plewes,et al.  Visualizing tissue compliance with MR imaging , 1995, Journal of magnetic resonance imaging : JMRI.

[25]  A. Manduca,et al.  Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. , 1995, Science.

[26]  K J Parker,et al.  Tissue response to mechanical vibrations for "sonoelasticity imaging". , 1990, Ultrasound in medicine & biology.

[27]  F. Terrier,et al.  Magnetic Resonance Imaging With Hepatospecific Contrast Agents in Cirrhotic Rat Livers , 2005, Investigative radiology.

[28]  Joyce R. McLaughlin,et al.  Unique identifiability of elastic parameters from time-dependent interior displacement measurement , 2004 .

[29]  R. Sinkus,et al.  High-resolution tensor MR elastography for breast tumour detection. , 2000, Physics in medicine and biology.

[30]  M. Bernstein,et al.  Comparison of phase‐difference and complex‐difference processing in phase‐contrast MR angiography , 1991, Journal of magnetic resonance imaging : JMRI.

[31]  Stefano Colagrande,et al.  Fibrosis in chronic liver diseases: diagnosis and management. , 2005, Journal of hepatology.

[32]  Ralph Sinkus,et al.  In Vivo MR-Elastography of Liver Fibrosis , 2005 .

[33]  Dieter Klatt,et al.  Fractional encoding of harmonic motions in MR elastography , 2007, Magnetic resonance in medicine.

[34]  M. Ziol,et al.  Assessment of biliary fibrosis by transient elastography in patients with PBC and PSC , 2006, Hepatology.

[35]  K. Ishak,et al.  Histological grading and staging of chronic hepatitis. , 1995 .

[36]  M. Ziol,et al.  Transient elastography: a new noninvasive method for assessment of hepatic fibrosis. , 2003, Ultrasound in medicine & biology.

[37]  N. Kato,et al.  Effect of Resovist on Rats With Different Severities of Liver Cirrhosis , 2002, Investigative radiology.

[38]  Y. Yamakoshi,et al.  Ultrasonic imaging of internal vibration of soft tissue under forced vibration , 1990, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.