Diagnostic yield of repeat capsule endoscopy and the effect on subsequent patient management.

BACKGROUND Capsule endoscopy (CE) has been shown to produce a high diagnostic yield in patients with obscure gastrointestinal bleeding (OGIB); however, in those with negative studies, management is controversial. Very few studies have reported on repeat CE in the same patient; data regarding this diagnostic strategy are limited. OBJECTIVE To determine the diagnostic yield of repeated CE studies and how this yield affects subsequent patient management. METHODS A retrospective chart review of all patients who underwent CE at St Paul's Hospital (Vancouver, British Columbia) between December 2001 and June 2009 was conducted. Patients who underwent subsequent repeat CE were identified and divided into one of four subgroups. Findings were classified as positive or negative. RESULTS Eighty-two of 676 patients underwent more than one CE study. Group 1 (incomplete study) included 22 patients (27%) and yielded 10 positive findings (45%). Group 2 (screening) comprised four patients (5%) and yielded two positive findings (50%). Group 3 (ongoing symptoms despite previous negative study) totalled 26 patients (32%) and yielded 10 positive findings (38%). Group 4 (previous positive study with treatment/investigation) included 30 patients (37%) and yielded 23 positive findings (77%). Overall, the present study found positive findings in 55% (45 of 82) of repeated CE cases, which resulted in a change in management in 39% (n=32) of the patients. CONCLUSION Due to the high diagnostic yield and noninvasive nature of CE, repeat CE appears to be of benefit and should be considered for specific patients before other types of small bowel studies.

[1]  D. Karamanolis,et al.  Is there a role for second-look capsule endoscopy in patients with obscure GI bleeding after a nondiagnostic first test? , 2009, Gastrointestinal endoscopy.

[2]  Ananya Das,et al.  Double-balloon enteroscopy and capsule endoscopy have comparable diagnostic yield in small-bowel disease: a meta-analysis. , 2008, Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association.

[3]  W. Frankel,et al.  The frequency of Muir-Torre syndrome among Lynch syndrome families. , 2008, Journal of the National Cancer Institute.

[4]  Irving Waxman,et al.  Double Balloon Enteroscopy Detects Small Bowel Mass Lesions Missed by Capsule Endoscopy , 2008, Digestive Diseases and Sciences.

[5]  Z. Ge,et al.  Purgative Bowel Cleansing Combined With Simethicone Improves Capsule Endoscopy Imaging , 2008, The American Journal of Gastroenterology.

[6]  E. Kuipers,et al.  Optimal preparation for video capsule endoscopy: a prospective, randomized, single-blind study. , 2007, Endoscopy.

[7]  N. Kalantzis,et al.  Effect of three bowel preparations on video-capsule endoscopy gastric and small-bowel transit time and completeness of the examination , 2007, Scandinavian journal of gastroenterology.

[8]  A. Hara,et al.  A Meta-Analysis of the Yield of Capsule Endoscopy Compared to Other Diagnostic Modalities in Patients with Obscure Gastrointestinal Bleeding , 2005, The American Journal of Gastroenterology.

[9]  J. Leighton,et al.  Yield of Repeat Wireless Video Capsule Endoscopy in Patients with Obscure Gastrointestinal Bleeding , 2005, The American Journal of Gastroenterology.

[10]  S. Ramirez,et al.  Is a 2-Liter PEG Preparation Useful Before Capsule Endoscopy? , 2005, Journal of clinical gastroenterology.

[11]  K. Schulmann,et al.  Feasibility and Diagnostic Utility of Video Capsule Endoscopy for the Detection of Small Bowel Polyps in Patients with Hereditary Polyposis Syndromes , 2005, The American Journal of Gastroenterology.

[12]  A. Panani,et al.  Bowel preparation increases the diagnostic yield of capsule endoscopy: a prospective, randomized, controlled study. , 2004, Gastrointestinal endoscopy.

[13]  P. Swain,et al.  Wireless capsule endoscopy. , 2002, The Israel Medical Association journal : IMAJ.

[14]  Zvi Fireman,et al.  Initial experience of wireless-capsule endoscopy for evaluating occult gastrointestinal bleeding and suspected small bowel pathology , 2002, American Journal of Gastroenterology.

[15]  S. Goodman,et al.  Very high risk of cancer in familial Peutz-Jeghers syndrome. , 2000, Gastroenterology.

[16]  R. Fodde,et al.  Cancer risk in families with hereditary nonpolyposis colorectal cancer diagnosed by mutation analysis. , 1996, Gastroenterology.

[17]  F. Giardiello,et al.  Phenotype and cancer risk of various polyposis syndromes. , 1995, European journal of cancer.

[18]  A. Rustgi Hereditary gastrointestinal polyposis and nonpolyposis syndromes. , 1994, The New England journal of medicine.

[19]  Luo Xiaoya American Gastroenterological Association(AGA) Institute medical position statement on obscure gastrointestinal bleeding , 2008 .

[20]  M. Fornasarig,et al.  Capsule endoscopy is useful and safe for small-bowel surveillance in familial adenomatous polyposis. , 2008, Gastrointestinal endoscopy.

[21]  K. Hörmann,et al.  [Tonsillectomy with the argon-plasma-coagulation-raspatorium - a prospective randomized single-blinded study]. , 2000, HNO.