Study on the system of a capsule endoscope driven by an outer rotational magnetic field

The system studied in this paper consists of a capsule endoscope and an external system. The exterior of the capsule endoscope is a spiral surface with a pair of magnetic bars. Inside the CE, there are an optical system, a CMOS image sensor and its circuit, a power supply, a power control circuit, and a radio transmitting circuit. The external system produces a rotational magnetic field and contains several main parts: three fixed magnet resistance transducers, two pairs of electromagnetic coils at every other 90deg, the basement of the electromagnetic coils and tracks, a control circuit, and a scheduling circuit. The magnet resistance transducers track the movement of the capsule endoscope and the electromagnetic coils control it to move forward and backward for the purpose of observation. A tester is set up to simulate the action of a rotating magnetic field and three capsule endoscope samples with a spiral surface are fabricated to perform the functions of imaging and delivering. Then, experiments that the samples move in off-body pig intestine are carried out. It is found that when the intensity of the outer magnetic field is about 500 Oe, the active torque on the samples is about 1.0 mN.m. When the diameter of the samples is less than 20 mm, the capsule endoscope can move normally in off-body pig intestine under the outer rotational magnetic field

[1]  J. A. Buck,et al.  Engineering Electromagnetics , 1967 .

[2]  K.R. Demarest,et al.  Engineering Electromagnetics , 1997, IEEE Electrical Insulation Magazine.

[3]  P. Swain,et al.  Wireless capsule endoscopy. , 2002, The Israel Medical Association journal : IMAJ.

[4]  Chen Xin A 3D LOCALIZING AND NAVIGATION METHOD FOR ENDOSCOPE BY MAGNETIC FIELD , 2002 .

[5]  K. Arai,et al.  Fabrication of magnetic actuator for use in a capsule endoscope , 2003 .

[6]  A. Glukhovsky,et al.  The development and application of wireless capsule endoscopy , 2004, The international journal of medical robotics + computer assisted surgery : MRCAS.

[7]  M.Q.-H. Meng,et al.  A low-cost tracking method based on magnetic marker for capsule endoscope , 2004, International Conference on Information Acquisition, 2004. Proceedings..

[8]  K. Arai,et al.  Spiral type magnetic micro actuators for medical applications , 2004, Micro-Nanomechatronics and Human Science, 2004 and The Fourth Symposium Micro-Nanomechatronics for Information-Based Society, 2004..

[9]  Experimental Study on Frictional Performances of a Micro Capsule-Like Equipment Sliding in Off-Body Chitterling , 2005 .