Temporal Trends in Quality of Care Among Recipients of Implantable Cardioverter-Defibrillators: Insights From the National Cardiovascular Data Registry

Background— The ICD Registry was established in 2006 in part to measure quality of care in patients undergoing implantation of implantable cardioverter-defibrillators (ICDs); however, whether outcomes have improved since initiation of the registry is unknown. Our objective was to examine changes over time in 3 quality metrics available from the registry. Methods and Results— We performed an observational study of 367 153 patients who received new ICD implants from April 2006 to March 2010. Three quality metrics were selected: Adverse events (in-hospital complications or mortality), optimal medical therapy (OMT), and cardiac resynchronization therapy (CRT). OMT was defined as prescription of &bgr;-blocker and either angiotensin-converting enzyme inhibitor or angiotensin receptor blocker in eligible patients. CRT eligibility was determined by QRS ≥120 ms, left ventricular ejection fraction ⩽35%, and New York Heart Association class III/IV. Observation periods were divided into four 12-month intervals. We analyzed changes over time and used hierarchical logistic regression to adjust for potential confounders. Adverse events decreased over time (3.7% to 2.8%, P<0.001). Among eligible patients, rates of OMT and CRT increased over time (OMT: 69.0% to 74.3%, P<0.001; CRT: 80.5% to 84.2%, P<0.001). After adjustment for potential confounders, patients were significantly less likely to experience adverse events in year 4 than in year 1 (odds ratio, 0.75; 95% confidence interval, 0.71–0.79) and significantly more likely to receive OMT (odds ratio, 1.29; 95% confidence interval, 1.26–1.32) and CRT (odds ratio, 1.42; 95% confidence interval, 1.35–1.49). Conclusions— Since initiation of the ICD Registry, adverse events have been decreasing, and rates of OMT and CRT among eligible patients have been increasing, although there is still significant room for improvement.

[1]  M. Drazner,et al.  2013 ACCF/AHA guideline for the management of heart failure: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. , 2013, Journal of the American College of Cardiology.

[2]  Atul Verma,et al.  Pacemaker or defibrillator surgery without interruption of anticoagulation. , 2013, The New England journal of medicine.

[3]  J. Messenger,et al.  The National Cardiovascular Data Registry (NCDR) Data Quality Brief: the NCDR Data Quality Program in 2012. , 2012, Journal of the American College of Cardiology.

[4]  Optimal medical therapy use among patients receiving implantable cardioverter/defibrillators: insights from the National Cardiovascular Data Registry. , 2012, Archives of internal medicine.

[5]  J. Curtis,et al.  Implantable Cardioverter-Defibrillator Registry Risk Score Models for Acute Procedural Complications or Death After Implantable Cardioverter-Defibrillator Implantation , 2011, Circulation.

[6]  M. Cheitlin Characteristics of heart failure patients associated with good and poor response to cardiac resynchronization therapy: a PROSPECT (Predictors of Response to CRT) sub-analysis , 2011 .

[7]  John L Sapp,et al.  Cardiac-resynchronization therapy for mild-to-moderate heart failure. , 2010, The New England journal of medicine.

[8]  P. Heidenreich,et al.  The relation between hospital procedure volume and complications of cardioverter-defibrillator implantation from the implantable cardioverter-defibrillator registry. , 2010, Journal of the American College of Cardiology.

[9]  I. Piña,et al.  Review of the registry's fourth year, incorporating lead data and pediatric ICD procedures, and use as a national performance measure. , 2010, Heart rhythm.

[10]  J. Curtis,et al.  Prevalence and predictors of off-label use of cardiac resynchronization therapy in patients enrolled in the National Cardiovascular Data Registry Implantable Cardiac-Defibrillator Registry. , 2010, Journal of the American College of Cardiology.

[11]  Eugene Crystal,et al.  Evaluation of early complications related to De Novo cardioverter defibrillator implantation insights from the Ontario ICD database. , 2010, Journal of the American College of Cardiology.

[12]  Wojciech Zareba,et al.  Cardiac-resynchronization therapy for the prevention of heart-failure events. , 2009, The New England journal of medicine.

[13]  Claudia Stöllberger,et al.  Guidelines for device-based therapy of cardiac rhythm abnormalities. , 2009, Heart rhythm.

[14]  William T. Abraham,et al.  Focused Update : ACCF / AHA Guidelines for the Diagnosis and Management of Heart Failure in Adults , 2013 .

[15]  J. Ornato,et al.  ACC/AHA/HRS 2008 Guidelines for device-based therapy of cardiac rhythm abnormalities. , 2008, Heart rhythm.

[16]  B. Lindsay,et al.  Review of the registry's first year, data collected, and future plans. , 2007, Heart rhythm.

[17]  Harlan M Krumholz,et al.  Hospital quality for acute myocardial infarction: correlation among process measures and relationship with short-term mortality. , 2006, JAMA.

[18]  Z. Goldberger,et al.  Implantable cardioverter-defibrillators: expanding indications and technologies. , 2006, JAMA.

[19]  M. Mcclellan,et al.  Medicare coverage of ICDs. , 2005, The New England journal of medicine.

[20]  Data Collection , 1985 .