HPFRC Jacketing of Non Seismically Detailed RC Corner Joints

In this article, the effectiveness of a High-Performance Fiber-Reinforced Concrete (HPFRC) jacket for the seismic retrofitting of existing RC corner beam-column joints is experimentally investigated. The results of cyclic experimental tests on full-scale corner beam-column sub-assemblies (two unretrofitted and two retrofitted) are presented and discussed in detail, focusing on the effectiveness of the adopted retrofitting technique. The RC test units were designed with structural deficiencies typical of the Italian construction practice of the 1970s: use of smooth bars, inadequate reinforcement detailing, such as lack of stirrups in the joint panel, and hook-ended anchorage. The results underlined that the joint panel strength impairs the seismic response of the sub-structure with a drift at incipient collapse not greater than 2%. The results showed that the application of thin HPFRC jackets appears a promising technique to strengthen poorly-detailed RC joints: the jacket was able to increase the shear strength of the joint by about 40%, with respect to the bare joint, limiting the damage of the retrofitted sub-assembly, which reached an ultimate drift of 6%.

[1]  John B. Mander,et al.  Seismic Resistance of Reinforced Concrete Frame Structures Designed for Gravity Loads: Performance of Structural System , 1995 .

[2]  Bruce R. Ellingwood,et al.  Modeling Beam-Column Joints in Fragility Assessment of Gravity Load Designed Reinforced Concrete Frames , 2008 .

[3]  Rolf Eligehausen,et al.  Pushover experiment and analysis of a full scale non-seismically detailed RC structure , 2013 .

[4]  Constantin E. Chalioris,et al.  Local retrofit of exterior RC beam–column joints using thin RC jackets—An experimental study , 2008 .

[5]  A. Carr,et al.  Modelling of shear hinge mechanism in poorly detailed RC beam-column joints , 2003 .

[6]  Stefano Pampanin,et al.  Influence of slab on the seismic response of sub-standard detailed exterior reinforced concrete beam column joints , 2010 .

[7]  John B. Mander,et al.  Seismic Resistance of Reinforced Concrete Frame Structures Designed Only for Gravity Loads: Experimental Performance of Subassemblages , 1994 .

[8]  Gaetano Russo,et al.  Seismic Behavior of Exterior Beam-Column Connections with Plain Bars and Effects of Upgrade , 2012 .

[9]  M. Priestley DISPLACEMENT-BASED SEISMIC ASSESSMENT OF REINFORCED CONCRETE BUILDINGS , 1997 .

[10]  T. Almusallam,et al.  Seismic Response of FRP-Upgraded Exterior RC Beam-Column Joints , 2010 .

[11]  A. Mukherjee,et al.  FRPC reinforced concrete beam-column joints under cyclic excitation , 2005 .

[12]  C. Pantelides,et al.  Shear Strengthening of RCT-Joints Using CFRP Composites , 2000 .

[13]  Paolo Riva,et al.  Modelling of exterior beam to column joint in ’60-70s RC existing buildings , 2012 .

[14]  Gian Michele Calvi,et al.  Studio sperimentale sulla risposta sismica di edifici a telaio in cemento armato progettati per soli carichi da gravita , 2001 .

[15]  C. Murty,et al.  Effectiveness of Reinforcement Details in Exterior Reinforced Concrete Beam-Column Joints for Earthquake Resistance , 2003 .

[16]  S. Pampanin,et al.  China EFFECTS OF VARIATION OF AXIAL LOAD AND BI-DIRECTIONAL LOADING ON THE FRP RETROFIT OF EXISTING B-C JOINTS , 2008 .

[17]  A. Meda,et al.  Strengthening and repair of RC beams with fiber reinforced concrete , 2010 .

[18]  Alberto Meda,et al.  Column and Joint Retrofitting with High Performance Fiber Reinforced Concrete Jacketing , 2011 .

[19]  Franco Braga,et al.  R/C Existing Structures with Smooth Reinforcing Bars: Experimental Behaviour of Beam-Column Joints Subject to Cyclic Lateral Loads , 2009 .

[20]  N. Lakshmanan,et al.  Analytical and experimental investigations on seismic performance of exterior beam–column subassemblages of existing RC‐framed building , 2013 .

[21]  Angelo Masi,et al.  Cyclic Tests on External RC Beam-Column Joints: Role of Seismic Design Level and Axial Load Value on the Ultimate Capacity , 2013 .

[22]  A W Beeby,et al.  CONCISE EUROCODE FOR THE DESIGN OF CONCRETE BUILDINGS. BASED ON BSI PUBLICATION DD ENV 1992-1-1: 1992. EUROCODE 2: DESIGN OF CONCRETE STRUCTURES. PART 1: GENERAL RULES AND RULES FOR BUILDINGS , 1993 .

[23]  Costas P. Antonopoulos,et al.  EXPERIMENTAL INVESTIGATION OF FRP-STRENGTHENED RC BEAM-COLUMN JOINTS , 2003 .

[24]  R. Park,et al.  Seismic Load Tests on Interior and Exterior Beam-Column Joints with Substandard Reinforcing Details , 2000 .

[25]  Giuseppe Campione,et al.  RC columns externally strengthened with RC jackets , 2014 .

[26]  M. Fardis,et al.  Designer's guide to EN 1998-1 and en 1998-5 Eurocode 8: Design of structures for earthquake resistance; general rules, seismic actions, design rules for buildings, foundations and retaining structures/ M.Fardis[et al.] , 2005 .

[27]  Rolf Eligehausen,et al.  A new model to simulate joint shear behavior of poorly detailed beam–column connections in RC structures under seismic loads, Part I: Exterior joints , 2011 .