INVESTIGATION OF URINARY EXCRETION OF HYDROXYETHYL STARCH AND DEXTRAN BY UHPLC-HRMS IN DIFFERENT ACQUISITION MODES

Plasma volume expanders (PVEs) such as hydroxyethyl starch (HES) and dextran are misused in sports because they can prevent dehydration and reduce haematocrit values to mask erythropoietin abuse. Endogenous hydrolysis generates multiple HES and dextran oligosaccharides which are excreted in urine. Composition of the urinary metabolic profiles of PVEs varies depending on post-administration time and can have an impact on their detectability. In this work, different mass spectrometry data acquisition modes (full scan with and without in-source collision-induced dissociation) were used to study urinary excretion profiles of HES and dextran, particularly by investigating time-dependent detectability of HES and dextran urinary oligosaccharide metabolites in post-administration samples. In-source fragmentation yielded the best results in terms of limit of detection (LOD) and detection times, whereas detection of HES and dextran metabolites in full scan mode with no in-source fragmentation is related to recent administration (< 24 hours). Urinary excretion studies showed detection windows for HES and dextran respectively of 72 and 48 hours after administration. Dextran concentrations were above the previously proposed threshold of 500 µg · mL−1 for 12 hours. A “dilute-and-shoot” method for the detection of HES and dextran in human urine by ultra-high-pressure liquid chromatography-electrospray ionization-high resolution Orbitrap™ mass spectrometry was developed for this study. Validation of the method showed an LOD in the range of 10-500 µg · mL−1 for the most significant HES and dextran metabolites in the different modes. The method allows retrospective data analysis and can be implemented in existing high-resolution mass spectrometry-based doping control screening analysis.

[1]  F. Botrè,et al.  A rapid analytical method for the detection of plasma volume expanders and mannitol based on the urinary saccharides and polyalcohols profile. , 2011, Drug testing and analysis.

[2]  M. Thevis,et al.  High-throughput screening for various classes of doping agents using a new 'dilute-and-shoot' liquid chromatography-tandem mass spectrometry multi-target approach. , 2011, Drug testing and analysis.

[3]  K. Deventer,et al.  Specific screening method for dextran and hydroxyethyl starch in human urine by size exclusion chromatography–in-source collision-induced dissociation–time-of-flight mass spectrometry , 2011, Analytical and bioanalytical chemistry.

[4]  F. R. A. Aquino Neto,et al.  Plasma volume expanders: use in medicine and detecting misuse in sports. , 2011, Bioanalysis.

[5]  Monica Mazzarino,et al.  Microwave irradiation for a fast gas chromatography-mass spectrometric analysis of polysaccharide-based plasma volume expanders in human urine. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[6]  S. Mitra,et al.  Are All Colloids Same? How to Select the Right Colloid? , 2009, Indian journal of anaesthesia.

[7]  M. Padilha,et al.  Analytical and logistical improvements in doping-control analysis at the 2007 Pan-American Games , 2008 .

[8]  M. Thevis,et al.  Rapid screening of polysaccharide-based plasma volume expanders dextran and hydroxyethyl starch in human urine by liquid chromatography-tandem mass spectrometry. , 2008, Biomedical chromatography : BMC.

[9]  J. Son,et al.  Screening and confirmation analyses of urinary plasma volume expanders , dextran and HES , in doping control , 2007 .

[10]  M. Thevis,et al.  Mass spectrometry in sports drug testing: Structure characterization and analytical assays. , 2007, Mass spectrometry reviews.

[11]  K. Deventer,et al.  Detection of hydroxyethylstarch (HES) in human urine by liquid chromatography-mass spectrometry. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[12]  W. Kulicke,et al.  Improvements in Polysaccharides for use as Blood Plasma Expanders , 2005 .

[13]  M. Thevis,et al.  Identification and quantification of the plasma volume expander dextran in human urine by liquid chromatography-tandem mass spectrometry of enzymatically derived isomaltose. , 2005, Biomedical chromatography : BMC.

[14]  J. Chmelík,et al.  Different behavior of dextrans in positive-ion and negative-ion mass spectrometry. , 2004, Journal of mass spectrometry : JMS.

[15]  R. Gutiérrez Gallego,et al.  Rapid screening of plasma volume expanders in urine using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. , 2004, Rapid communications in mass spectrometry : RCM.

[16]  F. Arriaga,et al.  Fatal dextran‐induced allergic anaphylaxis , 2002, Allergy.

[17]  M. Thevis,et al.  Detection of the plasma volume expander hydroxyethyl starch in human urine. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[18]  S. Bratton,et al.  Colloid volume expanders. Problems, pitfalls and possibilities. , 1998, Drugs.

[19]  K. Tremper,et al.  Blood and plasma substitutes--plasma expansion and oxygen transport properties. , 1985, The Western journal of medicine.

[20]  C. R. Ricketts,et al.  Urinary excretion kinetics of hydroxyethyl starch 350/0.60 in normovolaemic man. , 1981, Journal of clinical pathology.

[21]  G. Arturson,et al.  THE INTRAVASCULAR PERSISTENCE OF DEXTRAN OF DIFFERENT MOLECULAR SIZES IN NORMAL HUMANS. , 1964, Scandinavian journal of clinical and laboratory investigation.