Automation of column-based radiochemical separations: a comparison of fluidic, robotic, and hybrid architectures

Abstract Two automated systems have been developed to perform column-based radiochemical separation procedures. These new systems are compared with past fluidic column separation architectures, with emphasis on using disposable components so that no sample contacts any surface that any other sample has contacted, and setting up samples and columns in parallel for subsequent automated processing. In the first new approach, a general purpose liquid handling robot has been modified and programmed to perform anion exchange separations using 2 mL bed columns in 6 mL plastic disposable column bodies. In the second new approach, a fluidic system has been developed to deliver clean reagents through disposable manual valves to six disposable columns, with a mechanized fraction collector that positions one of four rows of six vials below the columns. The samples are delivered to each column via a manual 3-port disposable valve from disposable syringes. This second approach, a hybrid of fluidic and mechanized components, is a simpler more efficient approach for performing anion exchange procedures for the recovery and purification of plutonium from samples. The automation architectures described can also be adapted to column-based extraction chromatography separations.

[1]  E. P. Horwitz,et al.  Extraction chromatography: Progress and opportunities , 1997 .

[2]  J. Grate,et al.  Automating Analytical Separations in Radiochemistry , 1998 .

[3]  J. Grate,et al.  Sequential Injection Renewable Separation Column Instrument for Automated Sorbent Extraction Separations of Radionuclides , 1998 .

[4]  Tony J. Beugelsdijk,et al.  12 – ROBOTICS AND AUTOMATION IN RADIOCHEMICAL ANALYSIS , 1998 .

[5]  J. Grate,et al.  Extraction chromatographic separations and analysis of actinides using sequential injection techniques with on-line inductively coupled plasma mass spectrometry (ICP MS) detection , 2001 .

[6]  K. Buesseler,et al.  Size-fractionated plutonium isotopes in a coastal environment. , 2001, Journal of environmental radioactivity.

[7]  R. M. Izatt,et al.  Review of Selective Ion Separations at BYU Using Liquid Membrane and Solid Phase Extraction Procedures , 1997 .

[8]  R. M. Izatt,et al.  Accomplishment of difficult chemical separations using solid phase extraction , 1996 .

[9]  J. Grate,et al.  Automated radiochemical separation, analysis, and sensing , 2020, Handbook of Radioactivity Analysis: Volume 2.

[10]  U. Sansone,et al.  Determination of Pu isotope concentrations and isotope ratio by inductively coupled plasma mass spectrometry: a review of analytical methodology , 2007 .

[11]  J. Grate,et al.  Separation-optimized sequential injection method for rapid automated analytical separation of 90Sr in nuclear waste , 1999 .

[12]  R. D. Evans,et al.  Radionuclide determination in environmental samples by inductively coupled plasma mass spectrometry , 2006 .

[13]  Hill,et al.  Radiochemistry: inconvenient but indispensable , 2000, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[14]  R. M. Izatt,et al.  SOLID PHASE EXTRACTION OF IONS OF ANALYTICAL INTEREST USING MOLECULAR RECOGNITION TECHNOLOGY , 1994 .

[15]  J. Cortina,et al.  Developments in Solid-Liquid Extraction by Solvent-Impregnated Resins , 1997 .

[16]  K. Buesseler,et al.  Sources and migration of plutonium in groundwater at the Savannah River site. , 2002, Environmental science & technology.