Continuous monitoring of regional cerebral blood flow: experimental and clinical validation of a novel thermal diffusion microprobe.

OBJECT Current clinical neuromonitoring techniques lack adequate surveillance of cerebral perfusion. In this article, a novel thermal diffusion (TD) microprobe is evaluated for the continuous and quantitative assessment of intraparenchymal regional cerebral blood flow (rCBF). METHODS To characterize the temporal resolution of this new technique, rCBF measured using the TD microprobe (TD-rCBF) was compared with rCBF levels measured by laser Doppler (LD) flowmetry during standardized variations of CBF in a sheep model. For validation of absolute values, the microprobe was implanted subcortically (20 mm below the level of dura) into 16 brain-injured patients, and TD-rCBF was compared with simultaneous rCBF measurements obtained using stable xenon-enhanced computerized tomography scanning (sXe-rCBF). The two techniques were compared using linear regression analysis as well as the Bland and Altman method. Stable TD-rCBF measurements could be obtained throughout all 3- to 5-hour sheep experiments. During hypercapnia, TD-rCBF increased from 49.3+/-15.8 ml/100 g/min (mean +/- standard deviation) to 119.6+/-47.3 ml/100 g/ min, whereas hypocapnia produced a decline in TD-rCBF from 51.2+/-12.8 ml/100 g/min to 39.3+/-5.6 m/100 g/min. Variations in mean arterial blood pressure revealed an intact autoregulation with pressure limits of approximately 65 mm Hg and approximately 170 mm Hg. After cardiac arrest TD-rCBF declined rapidly to 0 ml/100 g/min. The dynamics of changes in TD-rCBF corresponded well to the dynamics of the LD readings. A comparison of TD-rCBF and sXe-rCBF revealed a good correlation (r = 0.89; p < 0.0001) and a mean difference of 1.1+/-5.2 ml/100 g/min between the two techniques. CONCLUSIONS The novel TD microprobe provides a sensitive, continuous, and real-time assessment of intraparenchymal rCBF in absolute flow values that are in good agreement with sXe-rCBF measurements. This study provides the basis for the integration of TD-rCBF into multimodal monitoring of patients who are at risk for secondary brain injury.

[1]  R. Britt,et al.  Chronic histological effects of ultrasonic hyperthermia on normal feline brain tissue. , 1986, Radiation research.

[2]  J Swedenborg,et al.  Effects of local hyperemia and edema on the biological zero in laser Doppler fluxmetry (LD). , 1992, International journal of microcirculation, clinical and experimental.

[3]  M. Choksey Cortical thermal clearance as a predictor of imminent neurological deterioration. , 1996, Cerebrovascular and brain metabolism reviews.

[4]  K. Messmer,et al.  Capillary Blood Perfusion during Postischemic Reperfusion in Striated Muscle , 1992, Plastic and reconstructive surgery.

[5]  Multimodal hemodynamic neuromonitoring--quality and consequences for therapy of severely head injured patients. , 1998, Acta neurochirurgica. Supplement.

[6]  G. DiResta,et al.  Application of laser Doppler flowmetry in neurosurgery. , 1996, Neurosurgery clinics of North America.

[7]  A. Gelb,et al.  The responsiveness of cerebral blood flow to changes in arterial carbon dioxide is maintained during propofol-nitrous oxide anesthesia in humans. , 1992, Anesthesiology.

[8]  M. Weinand,et al.  Continuous regional cerebral cortical blood flow monitoring in head-injured patients. , 1995, Neurosurgery.

[9]  J. Pickard,et al.  Monitoring of brain metabolism during aneurysm surgery using microdialysis and brain multiparameter sensors. , 1999, Neurological research.

[10]  A. Maas,et al.  Monitoring cerebral oxygenation: experimental studies and preliminary clinical results of continuous monitoring of cerebrospinal fluid and brain tissue oxygen tension. , 1993, Acta neurochirurgica. Supplementum.

[11]  G. Schneider,et al.  Monitoring of cerebral oxygenation in patients with severe head injuries: brain tissue PO2 versus jugular vein oxygen saturation. , 1996, Journal of neurosurgery.

[12]  L. Nordsletten,et al.  Cerebral blood flow measured with intracerebral laser-Dopplerflow probes and radioactive microspheres. , 1995, Journal of applied physiology.

[13]  H. Kontos,et al.  Vasomotion in cerebral microcirculation of awake rabbits. , 1988, The American journal of physiology.

[14]  F. Gibbs,et al.  CHANGES IN HUMAN CEREBRAL BLOOD FLOW CONSEQUENT ON ALTERATIONS IN BLOOD GASES , 1935 .

[15]  L. Carter,et al.  Cortical blood flow in controlled hypotension as measured by thermal diffusion 1 , 1973, Journal of neurology, neurosurgery, and psychiatry.

[16]  B. Gallhofer,et al.  Rhythmic activity of cat pial vessels in vivo. , 1981, European neurology.

[17]  C. Dickman,et al.  Continuous regional cerebral blood flow monitoring in acute craniocerebral trauma. , 1991, Neurosurgery.

[18]  J Meixensberger,et al.  Clinical experience with 118 brain tissue oxygen partial pressure catheter probes. , 1998, Neurosurgery.

[19]  U Dirnagl,et al.  Autoregulation of Cerebral Blood Flow in Experimental Focal Brain Ischemia , 1990, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[20]  J. Gross,et al.  Vasomotion, tissue fluid flow and the formation of lymph. , 1982, International journal of microcirculation, clinical and experimental.

[21]  A. Nuttall,et al.  Cochlear blood flow increases after systemic hemodilution: Comparison of simultaneous laser doppler flowmetry and radioactive microsphere measurements , 1988, Hearing Research.

[22]  Increased inspired oxygen concentration as a factor in improved brain tissue oxygenation and tissue lactate levels after severe human head injury , 1999 .

[23]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[24]  K. Hoedt-Rasmussen,et al.  Regional cerebral blood flow. The intra-arterial injection method. , 1967, Acta neurologica Scandinavica.

[25]  W. Penfield EPILEPSY, THE GREAT TEACHER , 1967 .

[26]  O. Kirkeby,et al.  Effect of reduced cerebral perfusion pressure on cerebral blood flow following inhibition of nitric oxide synthesis. , 1998, Journal of neurosurgery.

[27]  K. Ohta,et al.  Comparison between the Photoelectric Method and H2 Clearance Method for Measuring Cerebrocortical Blood Flow in Cats , 1988, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[28]  J O Skarphedinsson,et al.  Repeated measurements of cerebral blood flow in rats. Comparisons between the hydrogen clearance method and laser Doppler flowmetry. , 1988, Acta physiologica Scandinavica.

[29]  R. Bullock,et al.  Brain oxygen, CO2, pH, and temperature monitoring: evaluation in the feline brain. , 1995, Neurosurgery.

[30]  E. Kochs,et al.  Correlation of Transcranial Doppler Sonography Mean Flow Velocity with Cerebral Blood Flow in Patients with Intracranial Pathology , 1998, Journal of neurosurgical anesthesiology.

[31]  M. Moskowitz,et al.  Cerebrovascular Responses under Controlled and Monitored Physiological Conditions in the Anesthetized Mouse , 1995, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[32]  W. Hoffman,et al.  Brain Tissue Oxygen, Carbon Dioxide, and pH in Neurosurgical Patients at Risk for Ischemia , 1996, Anesthesia and analgesia.

[33]  J A Krasney,et al.  Cerebral Blood Flow and Metabolic Responses to Sustained Hypercapnia in Awake Sheep , 1995, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[34]  D. Newell,et al.  The relationship of blood flow velocity fluctuations to intracranial pressure B waves. , 1992, Journal of neurosurgery.

[35]  H Yonas,et al.  CBF Measured by Xe-CT: Approach to Analysis and Normal Values , 1991, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[36]  G Ward,et al.  A critical review of laser Doppler flowmetry. , 1990, Journal of medical engineering & technology.

[37]  L. Carter,et al.  ICP-CBF trauma bolt, laboratory evaluation. , 1998, Acta neurochirurgica. Supplement.

[38]  L. Hillered,et al.  Neurochemical monitoring using intracerebral microdialysis in patients with subarachnoid hemorrhage. , 1996, Journal of neurosurgery.

[39]  G Otto,et al.  First clinical realization of continuous monitoring of liver microcirculation after transplantation by thermodiffusion. , 1996, Transplant international : official journal of the European Society for Organ Transplantation.

[40]  D. Graham,et al.  Cerebral Blood Flow in Rats During Physiological and Humoral Stimuli , 1981, Stroke.

[41]  R J Roman,et al.  Spontaneous Flow Oscillations in the Cerebral Cortex during Acute Changes in Mean Arterial Pressure , 1992, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[42]  U. Dirnagl,et al.  Continuous Measurement of Cerebral Cortical Blood Flow by Laser—Doppler Flowmetry in a Rat Stroke Model , 1989, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[43]  R Cooper,et al.  Regional control of cerebral vascular reactivity and oxygen supply in man. , 1966, Brain research.

[44]  J. Muizelaar,et al.  Monitoring of regional cerebral blood flow (CBF) in acute head injury by thermal diffusion. , 1993, Acta neurochirurgica. Supplementum.

[45]  R. Spetzler,et al.  Cortical Blood Flow During Extracranial-Intracranial Bypass Surgery , 1984, Stroke.

[46]  L. Carter Thermal diffusion flowmetry. , 1996, Neurosurgery clinics of North America.

[47]  W. Selman The Xenon-enhanced Computed Tomography Cerebral Blood Flow Method , 1998 .