An image registration strategy for multi‐echo fMRI

Functional magnetic resonance imaging (fMRI) based on multiple‐echo T2* mapping has attracted much attention recently. The contrasts in the parametric T2* maps are usually too low to allow direct image registration. In this study, an image registration strategy has been proposed for single‐shot multi‐echo data sets acquired for dynamic T2* mapping. We performed image registration of the T2*‐weighted images before the calculation of the T2* parameter maps using two different strategies. One is to perform separate image registration on each echo and the other is to use the same motion correction parameters extracted from the second echo for all the data. Both strategies increase the number of activated voxels and reduce the effective noise level. The results also indicate that, for a single‐shot dual‐echo image data set, it is slightly preferable to use the second echo for direct image registration and then apply the same motion correction parameters to the first echo images. J. Magn. Reson Imaging 1999;10:154–158. © 1999 Wiley‐Liss, Inc.

[1]  E. DeYoe,et al.  Reduction of physiological fluctuations in fMRI using digital filters , 1996, Magnetic resonance in medicine.

[2]  G H Glover,et al.  Decomposition of inflow and blood oxygen level‐dependent (BOLD) effects with dual‐echo spiral gradient‐recalled echo (GRE) fMRI , 1996, Magnetic resonance in medicine.

[3]  R W Cox,et al.  AFNI: software for analysis and visualization of functional magnetic resonance neuroimages. , 1996, Computers and biomedical research, an international journal.

[4]  Takahashi,et al.  A Pulse Sequence for Flow Evaluation Based on Self-Refocused RF and Interleaved Spiral Readout , 1997, Journal of magnetic resonance.

[5]  J. Mazziotta,et al.  Rapid Automated Algorithm for Aligning and Reslicing PET Images , 1992, Journal of computer assisted tomography.

[6]  A M Takahashi,et al.  ADC mapping by means of a single‐shot spiral MRI technique with application in acute cerebral ischemia , 1999, Magnetic resonance in medicine.

[7]  J. Mazziotta,et al.  MRI‐PET Registration with Automated Algorithm , 1993, Journal of computer assisted tomography.

[8]  B R Rosen,et al.  Mr contrast due to intravascular magnetic susceptibility perturbations , 1995, Magnetic resonance in medicine.

[9]  Karl J. Friston,et al.  Movement‐Related effects in fMRI time‐series , 1996, Magnetic resonance in medicine.

[10]  N C Andreasen,et al.  Functional MRI statistical software packages: A comparative analysis , 1998, Human brain mapping.

[11]  J Hennig,et al.  Functional Imaging by I0‐ and T2* ‐parameter mapping using multi‐image EPI , 1998, Magnetic resonance in medicine.

[12]  K. Uğurbil,et al.  Experimental determination of the BOLD field strength dependence in vessels and tissue , 1997, Magnetic resonance in medicine.

[13]  R. S. Hinks,et al.  Spin‐echo and gradient‐echo epi of human brain activation using bold contrast: A comparative study at 1.5 T , 1994, NMR in biomedicine.

[14]  R W Cox,et al.  Software tools for analysis and visualization of fMRI data , 1997, NMR in biomedicine.

[15]  J. Hajnal,et al.  Artifacts due to stimulus correlated motion in functional imaging of the brain , 1994, Magnetic resonance in medicine.

[16]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[17]  J. Hajnal,et al.  A Registration and Interpolation Procedure for Subvoxel Matching of Serially Acquired MR Images , 1995, Journal of computer assisted tomography.