Cerebral circulation estimated by laser speckle flowgraphy in retrograde femoral arterial perfusion during minimally invasive cardiac surgery.

OBJECTIVES Laser speckle flowgraphy (LSFG) is a novel modality to assess blood flow of the optic nerve head (ONH), which is reported to be a surrogate marker of cerebral microcirculation. We conducted LSFG measurements during minimally invasive cardiac surgery with retrograde femoral arterial perfusion and evaluated its feasibility and usability as a neuromonitor. METHODS We prospectively enrolled 7 patients who underwent mitral valve repair through a right minithoracotomy with retrograde femoral arterial perfusion. LSFG was used to analyse the ONH blood flow based on examinations of the mean blur rate (MBR). The MBR was measured after the induction of anaesthesia (time 1); after the initiation of cardiopulmonary bypass (time 2); during cardiac arrest (time 3) and after the termination of cardiopulmonary bypass (time 4). RESULTS All procedures were performed successfully, and there were no neurovascular complications or deaths. LSFG measurements were easily and uneventfully conducted without any related complications. The MBR was 11.2 ± 2.3 at time 1, 11.1 ± 1.8 at time 2, 11.3 ± 1.7 at time 3 and 13.6 ± 3.5 at time 4. Statistically, the MBR at time 4 was significantly higher than those at all other times ( P  < 0.05). CONCLUSIONS LSFG measurements were safely conducted during minimally invasive cardiac surgery and assessed ONH blood flow quantitatively. We consider this modality to be easy to manipulate and less operator dependent, resulting in good reproducibility. The results are well visualized and compared quantitatively. Our result suggests that LSFG might be an accurate neuromonitor. Clinical trial registration clinicaltrials.gov : 15102-2.

[1]  A. Hirakata,et al.  Observations of retinal vessels during intermittent pressure-augmented retrograde cerebral perfusion in clinical cases. , 2016, Interactive cardiovascular and thoracic surgery.

[2]  Hideaki Kawanishi,et al.  Ocular Blood Flow Measured Using Laser Speckle Flowgraphy During Aortic Arch Surgery With Antegrade Selective Cerebral Perfusion. , 2016, Journal of cardiothoracic and vascular anesthesia.

[3]  A. Lemaire,et al.  Femoral cannulation: a safe vascular access option for cardiopulmonary bypass in minimally invasive cardiac surgery , 2016, Perfusion.

[4]  T. Nakazawa,et al.  Age- and Sex-Dependency of Laser Speckle Flowgraphy Measurements of Optic Nerve Vessel Microcirculation , 2016, PloS one.

[5]  U. Kappert,et al.  Transcranial Doppler Sonography for Optimization of Cerebral Perfusion in Aortic Arch Operation. , 2016, The Annals of thoracic surgery.

[6]  Charles W. Hogue,et al.  Cerebral Near-Infrared Spectroscopy Monitoring and Neurologic Outcomes in Adult Cardiac Surgery Patients: A Systematic Review , 2013, Anesthesia and analgesia.

[7]  J. Wong,et al.  Cerebral and lower limb near-infrared spectroscopy in adults on extracorporeal membrane oxygenation. , 2012, Artificial organs.

[8]  T. Nakazawa,et al.  Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma , 2011, Clinical ophthalmology.

[9]  C. Pournaras,et al.  Institutional report - Cardiopulmonary bypass Blood flow measurements within optic nerve head during on-pump cardiovascular operations. A window to the brain? , 2011 .

[10]  G. Feuchtner,et al.  Distal leg protection for peripheral cannulation in minimally invasive and totally endoscopic cardiac surgery. , 2009, The heart surgery forum.

[11]  M Araie,et al.  Real-time measurement of human optic nerve head and choroid circulation, using the laser speckle phenomenon. , 1997, Japanese journal of ophthalmology.

[12]  N. Yoshimura,et al.  Ophthalmoscopic findings demonstrate reduced cerebral blood flow during retrograde cerebral perfusion. , 1995, The Journal of thoracic and cardiovascular surgery.