Chemometric analysis of gas chromatography-mass spectrometry data using fast retention time alignment via a total ion current shift function.

A critical comparison of methods for correcting severely retention time shifted gas chromatography-mass spectrometry (GC-MS) data is presented. The method reported herein is an adaptation to the piecewise alignment algorithm to quickly align severely shifted one-dimensional (1D) total ion current (TIC) data, then applying these shifts to broadly align all mass channels throughout the separation, referred to as a TIC shift function (SF). The maximum shift varied from (-) 5s in the beginning of the chromatographic separation to (+) 20s toward the end of the separation, equivalent to a maximum shift of over 5 peak widths. Implementing the TIC shift function (TIC SF) prior to Fisher Ratio (F-Ratio) feature selection and then principal component analysis (PCA) was found to be a viable approach to classify complex chromatograms, that in this study were obtained from GC-MS separations of three gasoline samples serving as complex test mixtures, referred to as types C, M and S. The reported alignment algorithm via the TIC SF approach corrects for large dynamic shifting in the data as well as subtle peak-to-peak shifts. The benefits of the overall TIC SF alignment and feature selection approach were quantified using the degree-of-class separation (DCS) metric of the PCA scores plots using the type C and M samples, since they were the most similar, and thus the most challenging samples to properly classify. The DCS values showed an increase from an initial value of essentially zero for the unaligned GC-TIC data to a value of 7.9 following alignment; however, the DCS was unchanged by feature selection using F-Ratios for the GC-TIC data. The full mass spectral data provided an increase to a final DCS of 13.7 after alignment and two-dimensional (2D) F-Ratio feature selection.

[1]  Rasmus Bro,et al.  Classification of GC‐MS measurements of wines by combining data dimension reduction and variable selection techniques , 2008 .

[2]  Fernando M. Maroto,et al.  ChromAlign: A two-step algorithmic procedure for time alignment of three-dimensional LC-MS chromatographic surfaces. , 2006, Analytical chemistry.

[3]  Kevin J Johnson,et al.  Classification of gasoline data obtained by gas chromatography using a piecewise alignment algorithm combined with feature selection and principal component analysis. , 2005, Journal of chromatography. A.

[4]  D. Saison,et al.  Determination of carbonyl compounds in beer by derivatisation and headspace solid-phase microextraction in combination with gas chromatography and mass spectrometry. , 2009, Journal of chromatography. A.

[5]  Bruce R. Kowalski,et al.  Second-order chemometric standardization for high-speed hyphenated gas chromatography: Analysis of GC/MS and comprehensive GCGC data , 1999 .

[6]  J. S. Ribeiro,et al.  Prediction of sensory properties of Brazilian Arabica roasted coffees by headspace solid phase microextraction-gas chromatography and partial least squares. , 2009, Analytica chimica acta.

[7]  O. Andersen,et al.  Chromatographic preprocessing of GC-MS data for analysis of complex chemical mixtures. , 2005, Journal of chromatography. A.

[8]  J. D. Leeuw,et al.  A rapid routine to correct for skewing in gas chromatography/mass spectrometry , 1996 .

[9]  Jamin C. Hoggard,et al.  Comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry analysis of metabolites in fermenting and respiring yeast cells. , 2006, Analytical chemistry.

[10]  David B. Cooper,et al.  Application of headspace analysis, solvent extraction, thermal desorption and gas chromatography—mass spectrometry to the analysis of chemical warfare samples containing sulphur mustard and related compounds , 1993 .

[11]  R. Synovec,et al.  Increasing the number of analyzable peaks in comprehensive two-dimensional separations through chemometrics. , 2001, Analytical chemistry.

[12]  Giorgio Tomasi,et al.  Chemical fingerprinting of petroleum biomarkers using time warping and PCA. , 2005, Environmental science & technology.

[13]  Richard G. Brereton,et al.  Pattern Recognition of Gas Chromatography Mass Spectrometry of Human Volatiles in Sweat to distinguish the sex of subjects and determine potential Discriminatory Marker Peaks , 2007 .

[14]  D. Massart,et al.  Comparison between the direct trilinear decomposition and the multivariate curve resolution-alternating least squares methods for the resolution of three-way data sets , 1998 .

[15]  Victoria L McGuffin,et al.  Chemometric analysis of diesel fuel for forensic and environmental applications. , 2008, Analytica chimica acta.

[16]  Frans van den Berg,et al.  Correlation optimized warping and dynamic time warping as preprocessing methods for chromatographic data , 2004 .

[17]  Y. Heyden,et al.  Prediction of total green tea antioxidant capacity from chromatograms by multivariate modeling. , 2005, Journal of chromatography. A.

[18]  R. Abagyan,et al.  XCMS: processing mass spectrometry data for metabolite profiling using nonlinear peak alignment, matching, and identification. , 2006, Analytical chemistry.

[19]  Jamin C. Hoggard,et al.  Comprehensive analysis of yeast metabolite GC x GC-TOFMS data: combining discovery-mode and deconvolution chemometric software. , 2007, The Analyst.

[20]  R. Synovec,et al.  Two-dimensional gas chromatography and trilinear partial least squares for the quantitative analysis of aromatic and naphthene content in naphtha. , 2001, Analytical chemistry.

[21]  R. Synovec,et al.  Trilinear chemometric analysis of two-dimensional comprehensive gas chromatography-time-of-flight mass spectrometry data. , 2004, Journal of chromatography. A.

[22]  Robert E. Synovec,et al.  Comprehensive Two-Dimensional High-Speed Gas Chromatography with Chemometric Analysis , 1998 .

[23]  D. Massart,et al.  A comparison of two algorithms for warping of analytical signals , 2002 .

[24]  Age K. Smilde,et al.  Optimized time alignment algorithm for LC-MS data: correlation optimized warping using component detection algorithm-selected mass chromatograms. , 2008, Analytical chemistry.

[25]  J. Carstensen,et al.  Aligning of single and multiple wavelength chromatographic profiles for chemometric data analysis using correlation optimised warping , 1998 .

[26]  C. Fraga,et al.  Chemometric approach for the resolution and quantification of unresolved peaks in gas chromatography--selected-ion mass spectrometry data. , 2003, Journal of chromatography. A.

[27]  R. Synovec,et al.  Objective data alignment and chemometric analysis of comprehensive two-dimensional separations with run-to-run peak shifting on both dimensions. , 2001, Analytical chemistry.

[28]  Bruce R. Kowalski,et al.  Standardization of Second-Order Chromatographic/Spectroscopic Data for Optimum Chemical Analysis , 1998 .

[29]  E. Marcotte,et al.  Chromatographic alignment of ESI-LC-MS proteomics data sets by ordered bijective interpolated warping. , 2006, Analytical chemistry.

[30]  B. W. Wright,et al.  High-speed peak matching algorithm for retention time alignment of gas chromatographic data for chemometric analysis. , 2003, Journal of chromatography. A.

[31]  B. W. Wright,et al.  Unsupervised parameter optimization for automated retention time alignment of severely shifted gas chromatographic data using the piecewise alignment algorithm. , 2007, Journal of chromatography. A.

[32]  Richard G Brereton,et al.  On-line HPLC combined with multivariate statistical process control for the monitoring of reactions. , 2007, Analytica chimica acta.

[33]  D. Penn,et al.  An automated method for peak detection and matching in large gas chromatography‐mass spectrometry data sets , 2006 .

[34]  Rasmus Bro,et al.  Automated alignment of chromatographic data , 2006 .

[35]  B. W. Wright,et al.  Classification of high-speed gas chromatography-mass spectrometry data by principal component analysis coupled with piecewise alignment and feature selection. , 2006, Journal of chromatography. A.

[36]  B. W. Wright,et al.  A comprehensive two-dimensional retention time alignment algorithm to enhance chemometric analysis of comprehensive two-dimensional separation data. , 2005, Analytical chemistry.

[37]  Robert Güth,et al.  Analysis of bacteria by pyrolysis gas chromatography-differential mobility spectrometry and isolation of chemical components with a dependence on growth temperature. , 2007, The Analyst.

[38]  Bruce R. Kowalski,et al.  Enhanced Chemical Analysis Using Parallel Column Gas Chromatography with Single-Detector Time-of-Flight Mass Spectrometry and Chemometric Analysis , 1999 .