Fault-Tolerant Control of Five-Phase Induction Motor Under Single-Phase Open

This paper deals with fault-tolerant control of five-phase induction motor (IM) drives under single-phase open. By exploiting a decoupled model for five-phase IM under fault, the indirect field-oriented control ensures that electromagnetic torque oscillations are reduced by particular magnitude ratio currents. The control techniques are developed by the third harmonic current injection, in order to improve electromagnetic torque density. Furthermore, Proportional Resonant (PR) regulator is adopted to realize excellent current tracking performance in the phase frame, compared with Proportional Integral (PI) and hysteresis regulators. The analysis and experimental results confirm the validity of fault-tolerant control under single-phase open.

[1]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady-state error , 2003 .

[2]  Hamid A. Toliyat,et al.  Five-phase induction motor drives with DSP-based control system , 2002 .

[3]  Gérard-André Capolino,et al.  Modeling and Control of Six-Phase Symmetrical Induction Machine Under Fault Condition Due to Open Phases , 2008, IEEE Transactions on Industrial Electronics.

[4]  H.A. Toliyat,et al.  A novel concept of a multiphase, multimotor vector controlled drive system supplied from a single voltage source inverter , 2004, IEEE Transactions on Power Electronics.

[5]  F. Briz,et al.  Dynamic analysis of current regulators for AC motors using complex vectors , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[6]  B. W. Williams,et al.  Improved Flux Pattern With Third Harmonic Injection for Multiphase Induction Machines , 2012, IEEE Transactions on Power Electronics.

[7]  Hamid Abolhasani Toliyat Analysis of concentrated winding induction and reluctance machines for adjustable speed drive applications , 1991 .

[8]  Hamid A. Toliyat,et al.  Multiphase induction motor drives - : a technology status review , 2007 .

[9]  Leila Parsa,et al.  Fault-Tolerant Control of Five-Phase Permanent-Magnet Motors With Trapezoidal Back EMF , 2011, IEEE Transactions on Industrial Electronics.

[10]  Brendan Peter McGrath,et al.  Current Regulation Strategies for Vector-Controlled Induction Motor Drives , 2012, IEEE Transactions on Industrial Electronics.

[11]  H. Toliyat,et al.  Five-phase permanent-magnet motor drives , 2005, IEEE Transactions on Industry Applications.

[12]  Abdelhadi Elbacha,et al.  Adaptive-Predictive Controller based on Continuous-Time Poisson-Laguerre Models for Induction Motor Speed Control Improvement , 2014 .

[13]  Y. Zhao,et al.  Modeling and control of a multi-phase induction machine with structural unbalance part II. Field-oriented control and experimental verification , 1996 .

[14]  D. G. Holmes,et al.  Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.

[15]  Y. Zhao,et al.  Modeling and control of a multi-phase induction machine with structural unbalance , 1996 .

[16]  Thomas A. Lipo,et al.  Analysis of a concentrated winding induction machine for adjustable speed drive applications. I. Motor analysis , 1991 .

[17]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[18]  D. Casadei,et al.  Control of Multiphase Induction Motors With an Odd Number of Phases Under Open-Circuit Phase Faults , 2012, IEEE Transactions on Power Electronics.

[19]  Emil Levi,et al.  Multiphase Electric Machines for , 2008 .

[20]  Hamid A. Toliyat,et al.  Rotor field oriented control of five-phase induction motor with the combined fundamental and third harmonic currents , 2001, APEC 2001. Sixteenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.01CH37181).

[21]  Seung-Ki Sul,et al.  Synchronous-frame current control of multiphase synchronous motor under asymmetric fault condition due to open phases , 2004, IEEE Transactions on Industry Applications.

[22]  Guy Clerc,et al.  On-line Faults Signature Monitoring Tool for Induction Motor Diagnosis , 2010 .

[23]  N. Bianchi,et al.  Strategies for the Fault-Tolerant Current Control of a Five-Phase Permanent-Magnet Motor , 2007, IEEE Transactions on Industry Applications.

[24]  John E. Fletcher,et al.  Dual-Plane Vector Control of a Five-Phase Induction Machine for an Improved Flux Pattern , 2008, IEEE Transactions on Industrial Electronics.

[25]  Hamid A. Toliyat,et al.  Resilient current control of five-phase induction motor under asymmetrical fault conditions , 2002, APEC. Seventeenth Annual IEEE Applied Power Electronics Conference and Exposition (Cat. No.02CH37335).

[26]  Ayman Samy Abdel-Khalik,et al.  Optimum Flux Distribution With Harmonic Injection for a Multiphase Induction Machine Using Genetic Algorithms , 2011, IEEE Transactions on Energy Conversion.

[27]  H.A. Toliyat,et al.  Five-phase permanent magnet motor drives for ship propulsion applications , 2005, IEEE Electric Ship Technologies Symposium, 2005..

[28]  Thomas A. Lipo,et al.  Disturbance free operation of a multiphase current regulated motor drive with an opened phase , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.