Velocity and diffusion imaging in dynamic NMR microscopy
暂无分享,去创建一个
[1] E. Purcell,et al. Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments , 1954 .
[2] E. Anderson,et al. Self‐Diffusion Studies by Means of Nuclear Magnetic Resonance Spin‐Echo Techniques , 1963 .
[3] E. Stejskal. Use of Spin Echoes in a Pulsed Magnetic‐Field Gradient to Study Anisotropic, Restricted Diffusion and Flow , 1965 .
[4] J. E. Tanner,et al. Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .
[5] P. Callaghan,et al. A pulsed field gradient system for a fourier transform spectrometer , 1980 .
[6] P. R. Moran. A flow velocity zeugmatographic interlace for NMR imaging in humans. , 1982, Magnetic resonance imaging.
[7] Peter G. Morris,et al. Nmr Imaging in Biomedicine , 1982 .
[8] Jörg Kärger,et al. The propagator representation of molecular transport in microporous crystallites , 1983 .
[9] D. Norris,et al. A new method of NMR flow imaging. , 1984, Physics in medicine and biology.
[10] P. Callaghan. Pulsed Field Gradient Nuclear Magnetic Resonance as a Probe of Liquid State Molecular Organization , 1985 .
[11] W G Bradley,et al. NMR Even Echo Rephasing in Slow Laminar Flow , 1984, Journal of computer assisted tomography.
[12] D. Firmin,et al. Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique , 1984, Journal of computer assisted tomography.
[13] M C Bushell,et al. PRELIMINARY COMMUNICATION: The spatial mapping of translational diffusion coefficients by the NMR imaging technique , 1985 .
[14] M O'Donnell,et al. NMR blood flow imaging using multiecho, phase contrast sequences. , 1985, Medical physics.
[15] Tamon Inouye,et al. NMR Flow Imaging , 1985 .
[16] Mitsuaki Arakawa,et al. Magnetic Resonance Imaging the Velocity Vector Components of Fluid Flow , 1985, Magnetic resonance in medicine.
[17] Rapid average‐flow velocity measurement by NMR , 1986, Magnetic resonance in medicine.
[18] Albert Macovski,et al. Magnetic Resonance Angiography , 1986, IEEE Transactions on Medical Imaging.
[19] M. K. Chung,et al. A new nuclear magnetic resonance imaging technique for unambiguous unidirectional measurement of flow velocity , 1986 .
[20] J P Ridgway,et al. A technique for velocity imaging using magnetic resonance imaging. , 1986, The British journal of radiology.
[21] A. Caprihan,et al. A new method for flow velocity measurement: Frequency encoded NMR , 1986, Magnetic resonance in medicine.
[22] P. R. Moran,et al. NMR Velocity-Selective Excitation Composites for Flow and Motion Imaging and Suppression of Static Tissue Signal , 1987, IEEE Transactions on Medical Imaging.
[23] Further improvement of high‐speed NMR flow‐velocity measurement using a differential phase‐encoding technique , 1987, Magnetic resonance in medicine.
[24] L Axel,et al. MR flow imaging by velocity-compensated/uncompensated difference images. , 1987, Journal of computer assisted tomography.
[25] P. Callaghan,et al. Sensitivity and resolution in NMR imaging , 1987 .
[26] P. Callaghan,et al. Measurement of the self-diffusion coefficient of water as a function of position in wheat grain using nuclear magnetic resonance imaging. , 1988, Biophysical journal.
[27] P. Callaghan,et al. RAPID COMMUNICATION: NMR microscopy of dynamic displacements: k-space and q-space imaging , 1988 .
[28] Y. Xia,et al. Circulation of water within wheat grain revealed by nuclear magnetic resonance micro-imaging , 1988, Nature.
[29] C L Dumoulin,et al. Three‐dimensional phase contrast angiography , 1989, Magnetic resonance in medicine.