Density-Gradient Mediated Band Extraction of Leukocytes from Whole Blood Using Centrifugo-Pneumatic Siphon Valving on Centrifugal Microfluidic Discs

Here we present retrieval of Peripheral Blood Mononuclear Cells by density-gradient medium based centrifugation for subsequent analysis of the leukocytes on an integrated microfluidic “Lab-on-a-Disc” cartridge. Isolation of white blood cells constitutes a critical sample preparation step for many bioassays. Centrifugo-pneumatic siphon valves are particularly suited for blood processing as they function without need of surface treatment and are ‘low-pass’, i.e., holding at high centrifugation speeds and opening upon reduction of the spin rate. Both ‘hydrostatically’ and ‘hydrodynamically’ triggered centrifugo-pneumatic siphon valving schemes are presented. Firstly, the geometry of the pneumatic chamber of hydrostatically primed centrifugo-pneumatic siphon valves is optimised to enable smooth and uniform layering of blood on top of the density-gradient medium; this feature proves to be key for efficient Peripheral Blood Mononuclear Cell extraction. A theoretical analysis of hydrostatically primed valves is also presented which determines the optimum priming pressure for the individual valves. Next, ‘dual siphon’ configurations for both hydrostatically and hydrodynamically primed centrifugo-pneumatic siphon valves are introduced; here plasma and Peripheral Blood Mononuclear Cells are extracted through a distinct siphon valve. This work represents a first step towards enabling on disc multi-parameter analysis. Finally, the efficiency of Peripheral Blood Mononuclear Cells extraction in these structures is characterised using a simplified design. A microfluidic mechanism, which we termed phase switching, is identified which affects the efficiency of Peripheral Blood Mononuclear Cell extraction.

[1]  Lee A. Walsh,et al.  Spin coating of hydrophilic polymeric films for enhanced centrifugal flow control by serial siphoning , 2014 .

[2]  F. Schwemmer,et al.  A microfluidic timer for timed valving and pumping in centrifugal microfluidics. , 2015, Lab on a chip.

[3]  J. Ducrée,et al.  Centrifugo-Magnetophoretic Purification of CD4+ Cells from Whole Blood Toward Future HIV/AIDS Point-of-Care Applications , 2014, Journal of laboratory automation.

[4]  Jun Yang,et al.  A lab-on-CD prototype for high-speed blood separation , 2008 .

[5]  R. Zengerle,et al.  Visualization of flow patterning in high-speed centrifugal microfluidics , 2005 .

[6]  Jens Ducrée,et al.  Centrifugo-pneumatic valving utilizing dissolvable films. , 2012, Lab on a chip.

[7]  R. Johnson,et al.  Behavior of capillary valves in centrifugal microfluidic devices prepared by three-dimensional printing , 2011 .

[8]  R. Zengerle,et al.  Integrated siphon-based metering and sedimentation of whole blood on a hydrophilic lab-on-a-disk , 2007, Biomedical microdevices.

[9]  F. Schwemmer,et al.  Centrifugo-dynamic inward pumping of liquids on a centrifugal microfluidic platform. , 2012, Lab on a chip.

[10]  A. Böyum,et al.  Isolation of mononuclear cells and granulocytes from human blood. Isolation of monuclear cells by one centrifugation, and of granulocytes by combining centrifugation and sedimentation at 1 g. , 1968, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[11]  Jintae Kim,et al.  Centrifugal microfluidics for biomedical applications. , 2010, Lab on a chip.

[12]  M. Madou,et al.  Geometry effects on blood separation rate on a rotating disc , 2013 .

[13]  Macdara Glynn,et al.  Centrifugal microfluidics for cell analysis. , 2012, Current opinion in chemical biology.

[14]  Marc Madou,et al.  Infrared controlled waxes for liquid handling and storage on a CD-microfluidic platform. , 2011, Lab on a chip.

[15]  R. Zengerle,et al.  Single-step centrifugal hematocrit determination on a 10-$ processing device , 2007, Biomedical microdevices.

[16]  Jens Ducrée,et al.  Spira mirabilis enhanced whole blood processing in a lab-on-a-disk , 2014 .

[17]  Jens Ducrée,et al.  Event-triggered logical flow control for comprehensive process integration of multi-step assays on centrifugal microfluidic platforms. , 2014, Lab on a chip.

[18]  Roland Zengerle,et al.  The centrifugal microfluidic Bio-Disk platform , 2007 .

[19]  Jens Ducrée,et al.  Array-based capture, distribution, counting and multiplexed assaying of beads on a centrifugal microfluidic platform. , 2012, Lab on a chip.

[20]  P. Noble,et al.  Separation of blood leukocytes by Ficoll gradient. , 1967, The Canadian veterinary journal = La revue veterinaire canadienne.

[21]  R. Burger,et al.  Comprehensive integration of homogeneous bioassays via centrifugo-pneumatic cascading. , 2013, Lab on a chip.

[22]  R. Zengerle,et al.  Centrifugal extraction of plasma from whole blood on a rotating disk. , 2006, Lab on a chip.

[23]  U. Schaff,et al.  Whole blood immunoassay based on centrifugal bead sedimentation. , 2011, Clinical chemistry.

[24]  Jens Ducrée,et al.  Label-free impedance detection of cancer cells from whole blood on an integrated centrifugal microfluidic platform. , 2015, Biosensors & bioelectronics.

[25]  Fatimah Ibrahim,et al.  Latex micro-balloon pumping in centrifugal microfluidic platforms. , 2014, Lab on a chip.

[26]  Marc Madou,et al.  Pneumatic pumping in centrifugal microfluidic platforms , 2010 .

[27]  H. Zola,et al.  Isolation of Whole Mononuclear Cells from Peripheral Blood and Cord Blood , 1996, Current protocols in immunology.

[28]  J. Schmitz,et al.  Comparison of the effects of Ficoll-Hypaque separation and whole blood lysis on results of immunophenotypic analysis of blood and bone marrow samples from patients with hematologic malignancies , 1995, Clinical and diagnostic laboratory immunology.

[29]  Dermot Diamond,et al.  A portable centrifugal analyser for liver function screening. , 2014, Biosensors & bioelectronics.

[30]  Preparation of Human Mononuclear Cell Populations and Subpopulations , 2009 .

[31]  Teodor Veres,et al.  Serial siphon valving for centrifugal microfluidic platforms , 2010 .

[32]  Fatimah Ibrahim,et al.  Vacuum/Compression Valving (VCV) Using Parrafin-Wax on a Centrifugal Microfluidic CD Platform , 2013, PloS one.

[33]  Jens Ducrée,et al.  Integrated micromixer for incubation and separation of cancer cells on a centrifugal platform using inertial and dean forces , 2015 .

[34]  Dermot Diamond,et al.  Optically addressable single-use microfluidic valves by laser printer lithography. , 2010, Lab on a chip.

[35]  Marc Madou,et al.  Lab on a CD. , 2006, Annual review of biomedical engineering.

[36]  Kevin W Eliceiri,et al.  NIH Image to ImageJ: 25 years of image analysis , 2012, Nature Methods.

[37]  Fatimah Ibrahim,et al.  Theoretical development and critical analysis of burst frequency equations for passive valves on centrifugal microfluidic platforms , 2012, Medical & Biological Engineering & Computing.

[38]  A. Tentori,et al.  Differential white cell count by centrifugal microfluidics. , 2010 .

[39]  Jerry M Chen,et al.  Analysis and experiment of capillary valves for microfluidics on a rotating disk , 2008 .

[40]  J. Ducrée,et al.  Rapid, low-cost and instrument-free CD4+ cell counting for HIV diagnostics in resource-poor settings. , 2014, Lab on a chip.

[41]  K. Jensen,et al.  Multiphase microfluidics: from flow characteristics to chemical and materials synthesis. , 2006, Lab on a chip.

[42]  Tae-Hyeong Kim,et al.  Fully integrated lab-on-a-disc for simultaneous analysis of biochemistry and immunoassay from whole blood. , 2011, Lab on a chip.

[43]  Jens Ducrée,et al.  Paper imbibition for timing of multi-step liquid handling protocols on event-triggered centrifugal microfluidic lab-on-a-disc platforms , 2015 .

[44]  Jens Ducrée,et al.  At-line bioprocess monitoring by immunoassay with rotationally controlled serial siphoning and integrated supercritical angle fluorescence optics. , 2013, Analytica chimica acta.

[45]  F. Schwemmer,et al.  Centrifugal microfluidic platforms: advanced unit operations and applications. , 2015, Chemical Society reviews.

[46]  Roland Zengerle,et al.  Direct hemoglobin measurement on a centrifugal microfluidic platform for point-of-care diagnostics , 2006 .