The functional consequences of chronic, physiologically effective intracortical microstimulation.

Many studies have demonstrated the ability of chronically implanted multielectrode arrays (MEAs) to extract information from the motor cortex of both humans and nonhuman primates. Similarly, many studies have shown the ability of intracortical microstimulation to impart information to the brain via a single or a few electrodes acutely implanted in sensory cortex of nonhuman primates, but relatively few microstimulation studies characterizing chronically implanted MEAs have been performed. Additionally, device and tissue damage have been reported at the levels of microstimulation used in these studies. Whether the damage resulting from microstimulation impairs the ability of MEAs to chronically produce physiological effects, however, has not been directly tested. In this study, we examined the functional consequences of multiple months of periodic microstimulation via chronically implanted MEAs at levels capable of evoking physiological responses, that is, electromyogram (EMG) activity. The functionality of the MEA and neural tissue was determined by measuring impedances, the ability of microstimulation to evoke EMG responses, and the recording of action potentials. We found that impedances and the number of recorded action potentials followed the previously reported trend of decreasing over time in both animals that received microstimulation and those which did not receive microstimulation. Despite these trends, the ability to evoke EMG responses and record action potentials was retained throughout the study. The results of this study suggest that intracortical microstimulation via MEAs did not cause functional failure, suggesting that MEA-based microstimulation is ready to transition into subchronic (< 30 days) human trials to determine whether complex spatiotemporal sensory percepts can be evoked by patterned microstimulation.

[1]  E. J. Tehovnik,et al.  Saccadic eye movements evoked by microstimulation of striate cortex , 2003, The European journal of neuroscience.

[2]  S. Cogan Neural stimulation and recording electrodes. , 2008, Annual review of biomedical engineering.

[3]  John H.R. Maunsell,et al.  Behavioral Detection of Electrical Microstimulation in Different Cortical Visual Areas , 2007, Current Biology.

[4]  C. Kufta,et al.  Visuotopic mapping through a multichannel stimulating implant in primate V1. , 2005, Journal of neurophysiology.

[5]  D. Kipke,et al.  Cortical microstimulation in auditory cortex of rat elicits best-frequency dependent behaviors , 2005, Journal of neural engineering.

[6]  R. Romo,et al.  Somatosensory discrimination based on cortical microstimulation , 1998, Nature.

[7]  Daryl R. Kipke,et al.  Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes , 2006, IEEE Transactions on Biomedical Engineering.

[8]  Jerald D. Kralik,et al.  Real-time prediction of hand trajectory by ensembles of cortical neurons in primates , 2000, Nature.

[9]  Nicholas G. Hatsopoulos,et al.  Brain-machine interface: Instant neural control of a movement signal , 2002, Nature.

[10]  Daryl R Kipke,et al.  Single electrode micro-stimulation of rat auditory cortex: an evaluation of behavioral performance , 2003, Hearing Research.

[11]  R A Normann,et al.  Chronic intracortical microstimulation (ICMS) of cat sensory cortex using the Utah Intracortical Electrode Array. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[12]  Warren M Slocum,et al.  Background luminance affects the detection of microampere currents delivered to macaque striate cortex , 2009, The European journal of neuroscience.

[13]  John H R Maunsell,et al.  Electrical microstimulation thresholds for behavioral detection and saccades in monkey frontal eye fields , 2008, Proceedings of the National Academy of Sciences.

[14]  E. J. Tehovnik Electrical stimulation of neural tissue to evoke behavioral responses , 1996, Journal of Neuroscience Methods.

[15]  E M Schmidt,et al.  Microstimulation mapping of precentral cortex during trained movements. , 1990, Journal of neurophysiology.

[16]  J.P. Donoghue,et al.  Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[17]  Dylan F. Cooke,et al.  Arm movements evoked by electrical stimulation in the motor cortex of monkeys. , 2005, Journal of neurophysiology.

[18]  Andrew B. Schwartz,et al.  Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics , 2006, Neuron.

[19]  R. Romo,et al.  Sensing without Touching Psychophysical Performance Based on Cortical Microstimulation , 2000, Neuron.

[20]  Yali Amit,et al.  Single-unit stability using chronically implanted multielectrode arrays. , 2009, Journal of neurophysiology.

[21]  E. J. Tehovnik,et al.  Direct and indirect activation of cortical neurons by electrical microstimulation. , 2006, Journal of neurophysiology.

[22]  Jerald D. Kralik,et al.  Chronic, multisite, multielectrode recordings in macaque monkeys , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[23]  V. Gilja,et al.  Neural Recording Stability of Chronic Electrode Arrays in Freely Behaving Primates , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  William F. Agnew,et al.  The Effects of Prolonged Intracortical Microstimulation on the Excitability of Pyramidal Tract Neurons in the Cat , 2004, Annals of Biomedical Engineering.

[25]  Nitish V. Thakor,et al.  Cortical decoding of individual finger and wrist kinematics for an upper-limb neuroprosthesis , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[26]  Victor Pikov,et al.  Neuronal loss due to prolonged controlled-current stimulation with chronically implanted microelectrodes in the cat cerebral cortex , 2010, Journal of neural engineering.

[27]  S. Ghosh Cytoarchitecture of sensorimotor areas in the cat cerebral cortex , 1997 .

[28]  Matthew D. Johnson,et al.  In vivo impedance spectroscopy of deep brain stimulation electrodes , 2009, Journal of neural engineering.

[29]  Stephen I. Ryu,et al.  Low-dimensional neural features predict muscle EMG signals , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[30]  R. Doty,et al.  Laminar variation in threshold for detection of electrical excitation of striate cortex by macaques. , 2005, Journal of neurophysiology.

[31]  K. E. Jones,et al.  A glass/silicon composite intracortical electrode array , 2006, Annals of Biomedical Engineering.

[32]  M. Brecht,et al.  Behavioural report of single neuron stimulation in somatosensory cortex , 2008, Nature.

[33]  J. Donoghue,et al.  Sensors for brain-computer interfaces , 2006, IEEE Engineering in Medicine and Biology Magazine.

[34]  Byron M. Yu,et al.  A high-performance brain–computer interface , 2006, Nature.

[35]  E. J. Tehovnik,et al.  Differential effects of laminar stimulation of V1 cortex on target selection by macaque monkeys , 2002, The European journal of neuroscience.

[36]  G. Loeb,et al.  Visual sensations produced by intracortical microstimulation of the human occipital cortex , 1990, Medical and Biological Engineering and Computing.

[37]  S. Cogan,et al.  Sputtered iridium oxide films for neural stimulation electrodes. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[38]  T. Aziz,et al.  Electron microscopy of tissue adherent to explanted electrodes in dystonia and Parkinson's disease. , 2004, Brain : a journal of neurology.

[39]  Shy Shoham,et al.  Robust, automatic spike sorting using mixtures of multivariate t-distributions , 2003, Journal of Neuroscience Methods.

[40]  N A Fitzsimmons,et al.  Primate Reaching Cued by Multichannel Spatiotemporal Cortical Microstimulation , 2007, The Journal of Neuroscience.

[41]  E. Schmidt,et al.  "Safe" charge-injection waveforms for iridium oxide (AIROF) microelectrodes , 2003, Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[42]  T S Davis,et al.  Multiple factors may influence the performance of a visual prosthesis based on intracortical microstimulation: nonhuman primate behavioural experimentation , 2011, Journal of neural engineering.

[43]  Rajmohan Bhandari,et al.  Neural electrode degradation from continuous electrical stimulation: Comparison of sputtered and activated iridium oxide , 2010, Journal of Neuroscience Methods.

[44]  Stuart F Cogan,et al.  Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation , 2004, Journal of Neuroscience Methods.

[45]  Daniel R. Merrill,et al.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols , 2005, Journal of Neuroscience Methods.

[46]  M. Graziano,et al.  Complex Movements Evoked by Microstimulation of Precentral Cortex , 2002, Neuron.

[47]  Daryl R Kipke,et al.  Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants , 2007, Journal of neural engineering.

[48]  R. Normann,et al.  A method for pneumatically inserting an array of penetrating electrodes into cortical tissue , 2006, Annals of Biomedical Engineering.

[49]  C. Kufta,et al.  Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex. , 1996, Brain : a journal of neurology.

[50]  Tirin Moore,et al.  Complex movements evoked by microstimulation of the ventral intraparietal area , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[51]  G. Deuschl,et al.  Deep brain stimulation: Postoperative issues , 2006, Movement disorders : official journal of the Movement Disorder Society.

[52]  D. Kipke,et al.  Microstimulation in auditory cortex provides a substrate for detailed behaviors , 2005, Hearing Research.

[53]  William T. Newsome,et al.  Cortical microstimulation influences perceptual judgements of motion direction , 1990, Nature.

[54]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[55]  Steven M Chase,et al.  Control of a brain–computer interface without spike sorting , 2009, Journal of neural engineering.