Amperometric sensing in the gas-phase

Abstract The design of amperometric sensors for gaseous species presents a challenge as the gas phase has to be brought into contact with a solid electrode as well as an electrolyte phase which usually is liquid. However, many species of analytical interest are electroactive, such as SO 2 , NO x , O 3 , CO, formaldehyde or ethanol, and electrochemical means are always attractive in designing sensors because the electronic signal is obtained directly. Therefore, different approaches have been implemented and some types of such sensors have been available commercially for quite some time. Nevertheless, many new developments with regard to an improvement of sensitivity, selectivity and in the construction of these devices have been reported over the last few years, as well as approaches to miniaturization. In this review it is attempted to give an overview of the state of the art of this field, highlighting recent developments.

[1]  N. Yamazoe,et al.  A compact amperometric NO2 sensor based on Na+ conductive solid electrolyte , 1998 .

[2]  N. Comisso,et al.  Pulsed amperometric detection of ethanol in breath by gold electrodes supported on ion exchange membranes (solid polymer electrolytes) , 1996 .

[3]  G. Tourillon,et al.  Precipitation of Metallic Platinum into Nafion Ionomer Membranes I . Experimental Results , 1993 .

[4]  Y. Sadaoka,et al.  Detection of gaseous hydrogen peroxide using planar-type amperometric cell at room temperature , 2000 .

[5]  Joseph R. Stetter,et al.  A room-temperature electrochemical sensor and instrument for monitoring methane , 1985 .

[6]  F. Opekar,et al.  Au/PVC composite—a new material for solid-state gas sensors: Detection of nitrogen dioxide in the air , 2004 .

[7]  J. Do,et al.  Electrochemical nitrogen dioxide gas sensor based on solid polymeric electrolyte , 1996 .

[8]  T. Springer,et al.  Water Uptake by and Transport Through Nafion® 117 Membranes , 1993 .

[9]  P. Jurs,et al.  Detection of hazardous gases and vapors: pattern recognition analysis of data from an electrochemical sensor array , 1986 .

[10]  Beat Müller,et al.  Determination of methane and other small hydrocarbons with a platinum–Nafion electrode by stripping voltammetry , 2001 .

[11]  J. Hart,et al.  A disposable amperometric gas sensor for sulphur-containing compounds based on a chemically modified screen printed carbon electrode coated with a hydrogel , 1997 .

[12]  O. Enea On the electrocatalytic oxidation of methanol vapors at Au-nafion electrodes , 1987 .

[13]  C. Hahn,et al.  The development of new microelectrode gas sensors: an odyssey. Part III. O2 and N2O reduction at unshielded and membrane-covered gold microdisc electrodes , 1997 .

[14]  I. Nikolov,et al.  Tungsten carbide-based electrochemical sensors for hydrogen determination in gas mixtures , 2000 .

[15]  Norio Miura,et al.  Selective detection of NO by using an amperometric sensor based on stabilized zirconia and oxide electrode , 1999 .

[16]  G. A. Dawson,et al.  Portable trap-sensor system for monitoring low levels of ethylene , 1997 .

[17]  R. Palombari,et al.  Amperometric solid-state sensor for NO and NO2 based on protonic conduction , 1996 .

[18]  S. Pons,et al.  The use of narrow gap microelectrodes as sensitive and species selective gas chromatographic detectors , 1989 .

[19]  S. Lieberman,et al.  Feasibility studies for the detection of volatile organic compounds in the gas phase using microelectrode sensors , 1999 .

[20]  Peter C. Hauser,et al.  Amperometric detection of NO and NO2 in the ppb range with solid-polymer electrolyte membrane supported noble metal electrodes , 2001 .

[21]  L. Niedrach,et al.  A New High‐Performance Fuel Cell Employing Conducting‐Porous‐Teflon Electrodes and Liquid Electrolytes , 1965 .

[22]  Peter C. Hauser,et al.  Amperometric Detection of Gaseous Formaldehydein the ppb Range , 2001 .

[23]  W. Göpel,et al.  A novel thick film sensor for simultaneous O2 and NO monitoring in exhaust gases , 2000 .

[24]  Kangli Wang,et al.  The Electrochemical Behavior and the Quantitative Determination of Nitrogen Dioxide at a Solid Polymer Electrolyte Supported Pt‐Au Electrode , 2004 .

[25]  J. Stetter,et al.  Amperometric Sensing of NO x with Cyclic Voltammetry , 2003 .

[26]  P. Hauser,et al.  Quantitative analysis of gas mixtures by voltammetric sensing , 2003 .

[27]  H. Nakajima,et al.  Metal electrodes bonded on solid polymer electrolyte membranes (SPE)—II. The polarization resistance of Pt-Nafion electrode , 1984 .

[28]  P. Millet,et al.  A solid polymer electrolyte-based ethanol gas sensor , 1996 .

[29]  Peter C. Hauser,et al.  Sensitive electrochemical detection of ozone , 2002 .

[30]  Bogdan Chachulski Amperometric sulfur dioxide gas sensor with dimethyl sulfoxide as solvent for internal electrolyte solution , 1998 .

[31]  B. Beden,et al.  Electrocatalytic oxidation of saturated oxygenated compounds on gold electrodes , 1987 .

[32]  C. Hahn,et al.  The development of new microelectrode gas sensors: an odyssey. Part 2. O2 and CO2 reduction at membrane-covered gold microdisc electrodes , 1995 .

[33]  J. Stetter,et al.  Sensitive electrochemical detector for gas chromatography , 1978 .

[34]  B. Hwang,et al.  Nafion-based solid-state gas sensors: Pt / Nafion electrodes prepared by an impregnation-reduction method in sensing oxygen , 1998 .

[35]  Rosanna Toniolo,et al.  Electroanalytical Sensors for Nonconducting Media Based on Electrodes Supported on Perfluorinated Ion-Exchange Membranes , 1997 .

[36]  Joseph R. Stetter,et al.  The properties and applications of amperometric gas sensors , 1992 .

[37]  P. Hauser,et al.  Electrochemical Sensor for Acetylene , 1997 .

[38]  Peter C. Hauser,et al.  Portable instrument for electrochemical gas sensing , 2003 .

[39]  N. Yamazoe,et al.  Amperometric sensor based on NASICON and NO oxidation catalysts for detection of total NOx in atmospheric environment , 2000 .

[40]  H. Nakajima,et al.  Metal electrodes bonded on solid polymer electrolyte membranes (SPE)—III. CO oxidation at Au-SPE electrodes , 1986 .

[41]  Karel Štulík,et al.  Electrochemical sensors with solid polymer electrolytes , 1999 .

[42]  C. Liu,et al.  Microfabricated thin-film microelectrode for amperometric determination of CO2 in the gas phase , 1994 .

[43]  Detection of volatile organic solvents using potentiodynamic gas sensors , 1997 .

[44]  I. Bergman Metallized Membrane Electrode: Atmospheric Oxygen Monitoring and other Applications , 1968, Nature.

[45]  G. A. Dawson,et al.  Humidity and temperature effects on the response to ethylene of an amperometric sensor utilizing a gold‐nafion electrode , 1997 .

[46]  T. Chou,et al.  Amperometric SO2 gas sensors based on solid polymer electrolytes , 2002 .

[47]  Gino Bontempelli,et al.  Amperometric monitoring of ozone in gaseous media by gold electrodes supported on ion exchange membranes (solid polymer electrolytes) , 1990 .

[48]  G. Zotti,et al.  Electrodes supported on ion-exchange membranes as sensors in gases and low-conductivity solvents , 1989 .

[49]  F. Opekar Analytical applications of metallized membrane electrodes , 1989 .

[50]  F. Opekar,et al.  Indicator and reference platinum | solid polymer electrolyte electrodes for a simple solid-state amperometric hydrogen sensor , 1994 .

[51]  W. Vielstich,et al.  On the quantitative determination of carbon dioxide in air.: A new sensor technique using anodic adsorbate stripping , 1993 .

[52]  Peter C. Hauser,et al.  Amperometric Sensor for Monitoring Ethylene , 1997 .

[53]  H. Nakajima,et al.  Metal electrodes bonded on solid polymer electrolyte membranes (SPE)—The behaviour of platinum bonded on SPE for hydrogen and oxygen electrode processes , 1983 .

[54]  J. Stetter,et al.  Electrochemical Oxidation of Methane in Nonaqueous Electrolytes at Room Temperature Application to Gas Sensors , 1985 .

[55]  Joseph R. Stetter,et al.  Microfabricated amperometric gas sensors , 1988 .

[56]  W. C. Maskell,et al.  Detection of water vapour or carbon dioxide using a zirconia pump-gauge sensor , 1999 .

[57]  P. Hauser,et al.  A New Nitric Oxide Gas Sensor Based on Reticulated Vitreous Carbon/Nafion and Its Applications , 2004 .

[58]  James A. Cox,et al.  Solid‐state amperometric sensors for gas phase analytes: A review of recent advances , 1997 .

[59]  Peter C. Hauser,et al.  Electrochemical Sensor for the Detection of SO2 in the Low-ppb Range , 1999 .

[60]  G. Hambitzer,et al.  Electrochemical detection of organic gases. The development of a formaldehyde sensor , 1990 .

[61]  P. Gifford,et al.  Separation and determination of volatile hydrides by gas chromatography with a gold gas-porous electrode detector , 1980 .

[62]  F. Opekar,et al.  Amperometric solid-state NO2 sensor based on plasticized PVC matrix containing a hydrophobic electrolyte , 1997 .

[63]  Rosanna Toniolo,et al.  Electrochemical Detection of Trace Hydrogen Sulfide in Gaseous Samples by Porous Silver Electrodes Supported on Ion-Exchange Membranes (Solid Polymer Electrolytes) , 1995 .

[64]  J. Do,et al.  Amperometric nitrogen dioxide gas sensor: preparation of PAn/Au/SPE and sensing behaviour , 2001 .

[65]  Larry R. Jordan,et al.  Amperometric Gas Sensors of High Sensitivity , 1999 .

[66]  Karel Štulík,et al.  An amperometric solid-state NO2 sensor with a solid polymer electrolyte and a reticulated vitreous carbon indicator electrode , 2000 .

[67]  David Bull,et al.  A connectionist approach to fuel cell sensor array processing for gas discrimination , 1993 .

[68]  Seong‐Hyeon Hong,et al.  Solid-state amperometric CO2 sensor using a lithium-ion conductor , 2003 .

[69]  Dennis H. Evans,et al.  Voltammetry without supporting electrolyte using a platinum working electrode supported on an ion exchange membrane , 1988 .

[70]  C. Liu,et al.  Development of a NASICON-based amperometric carbon dioxide sensor , 2000 .

[71]  Chunguang Liu,et al.  Electrochemical oxidation and the quantitative determination of carbon monoxide on metal–solid polymer electrolyte (SPE) system , 1991 .

[72]  T. Chou,et al.  Amperometric sulfur dioxide sensors using the gold deposited gas‐diffusion electrode , 1996 .

[73]  Rosanna Toniolo,et al.  Amperometric monitoring of sulphur dioxide in liquid and air samples of low conductivity by electrodes supported on ion-exchange membranes , 1991 .

[74]  P. Hauser,et al.  Amperometric sensing of ethylene oxide in the gas phase. , 2000, Analytical chemistry.

[75]  J. Leddy,et al.  Voltammetry in gas phase environments , 1995 .

[76]  F. Opekar An amperometric solid‐state sensor for Nitrogen dioxide based on a solid polymer electrolyte , 1992 .

[77]  C. Liu,et al.  A solid polymer electrolyte-bases electrochemical carbon monoxide sensor , 1994 .

[78]  Michael J. Tierney,et al.  Electrochemical gas sensor with extremely fast response times , 1993 .

[79]  Joseph R. Stetter,et al.  Electrochemical NO2 gas sensors: Model and mechanism for the electroreduction of NO2 , 1990 .

[80]  Juntao Lu,et al.  A Solid‐State Ozone Sensor Based on Solid Polymer Electrolyte , 1998 .

[81]  R WOLF,et al.  Continuous recording of blood oxygen tensions by polarography. , 1953, Journal of applied physiology.

[82]  Beat Müller,et al.  Amperometric detection of gaseous ethanol and acetaldehyde at low concentrations on an Au–Nafion electrode , 1999 .

[83]  K. Stulík,et al.  Amperometric Solid-State Gas Sensors: Materials for Their Active Components , 2002 .

[84]  Peter S. Fedkiw,et al.  In Situ Electrode Formation on a Nafion Membrane by Chemical Platinization , 1992 .

[85]  Norio Miura,et al.  A COMPACT SOLID-STATE AMPEROMETRIC SENSOR FOR DETECTION OF NO2 IN PPB RANGE , 1998 .

[86]  F. Ménil,et al.  Nitrogen monoxide detection with a planar spinel coated amperometric sensor , 2001 .