Temperature Monitoring during Radio Frequency Thermal Ablation Treatment on Ex Vivo perfused organ by Fiber Bragg Grating Sensors

In this work, we report on the integration of fiber Bragg gratings sensors in a commercial radio frequency probe for real-time temperature monitoring during thermal ablation of biological tissues. The experiments were conducted on ex-vivo pig liver and bovine kidney tissues and the results confirm that the proposed setup is able to conduct a multi-point real-time temperature monitoring during the RF discharges with a temperature resolution of 0.1 °C and a minimum spatial resolution of 1 mm. During these experiments the blood perfusion was implemented by injecting water at a temperature of 37 °C inside the organ under examination. This solution aimed at simulating the Radio Frequency Thermal Ablation (RFTA) treatments made in clinical practice.

[1]  Sergio Silvestri,et al.  Techniques for temperature monitoring during laser-induced thermotherapy: An overview , 2013, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[2]  Yuman Fong,et al.  A Retrospective Comparison of Microwave Ablation vs. Radiofrequency Ablation for Colorectal Cancer Hepatic Metastases , 2014, Annals of Surgical Oncology.

[3]  M D Sherar,et al.  Temperature measurement artefacts of thermocouples and fluoroptic probes during laser irradiation at 810 nm. , 2001, Physics in medicine and biology.

[4]  Huacai Chen,et al.  Study on Optical Fiber Bragg Grating Temperature Sensors for Human Body Temperature Monitoring , 2012, 2012 Symposium on Photonics and Optoelectronics.

[5]  R Jason Stafford,et al.  Laser-induced thermal therapy for tumor ablation. , 2010, Critical reviews in biomedical engineering.

[6]  D. Gervais,et al.  Renal cell carcinoma: clinical experience and technical success with radio-frequency ablation of 42 tumors. , 2003, Radiology.

[7]  Bruno Quesson,et al.  Magnetic resonance temperature imaging for guidance of thermotherapy , 2000, Journal of magnetic resonance imaging : JMRI.

[8]  E Schena,et al.  Temperature monitoring during microwave ablation in ex vivo porcine livers. , 2015, European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology.

[9]  Elfed Lewis,et al.  Fiber Optic Sensors for Temperature Monitoring during Thermal Treatments: An Overview , 2016, Sensors.

[10]  Sergio Silvestri,et al.  CT-based thermometry: An overview , 2014, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  H. H. Penns Analysis of tissue and arterial blood temperatures in the resting human forearm , 1948 .

[12]  Emiliano Schena,et al.  Assessment of temperature measurement error and its correction during Nd:YAG laser ablation in porcine pancreas , 2014, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[13]  G. Y. Wong,et al.  Painful metastases involving bone: percutaneous image-guided cryoablation--prospective trial interim analysis. , 2006, Radiology.

[14]  Christopher L Brace,et al.  Principles of and advances in percutaneous ablation. , 2011, Radiology.

[15]  Agostino Iadicicco,et al.  Temperature monitoring during thermal ablation on ex-vivo organs by Fiber Bragg gratings , 2016, 2016 IEEE SENSORS.

[16]  Rajiv Chopra,et al.  Thermometry and ablation monitoring with ultrasound , 2015, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[17]  Luigi Solbiati,et al.  Treatment of focal liver tumors with percutaneous radio-frequency ablation: complications encountered in a multicenter study. , 2003, Radiology.

[18]  Agostino Iadicicco,et al.  Temperature profile of ex-vivo organs during radio frequency thermal ablation by fiber Bragg gratings , 2016, Journal of biomedical optics.

[19]  Elfed Lewis,et al.  Intra-Tissue Pressure Measurement in Ex Vivo Liver Undergoing Laser Ablation with Fiber-Optic Fabry-Perot Probe , 2016, Sensors.

[20]  G. Ehnholm,et al.  Volumetric HIFU ablation under 3D guidance of rapid MRI thermometry. , 2009, Medical physics.

[21]  T. Erdogan Fiber grating spectra , 1997 .

[22]  Sergio Silvestri,et al.  Feasibility of EUS-guided Nd:YAG laser ablation of unresectable pancreatic adenocarcinoma. , 2018, Gastrointestinal endoscopy.