A hybrid device for electrical impedance tomography and bioelectrical impedance spectroscopy measurement

We proposed a hybrid device, which is capable of measuring either bioelectrical impedance spectroscopy (BIS) or electrical impedance tomography (EIT) based on the Magnitude Ratio and Phase Difference Detection method. Frequency range available for measuring is from 1 kHz to 1 MHz. The device is based on The Freescale Tower system module with S08MM Freescale microcontroller. The proposed device is divided into two modules. One of them includes measurement chain, the second one contains four multiplexers, which connect always four electrodes to the circuit from total amount of sixteen electrodes. Both modules are connected via Tower elevator modules. While measuring impedance the systematic error occured, so we used the Quadratic Interpolation Self-calibration algorithm for calculation of the measured impedance. Calibration was applied on the absolute value of impedance. Calibration on the phase shift has not been done yet, since both input signals to GPD are highly disturbed with the noise, although they pass through a low-pass filter with cut-off frequency of 1 MHz. The superposed noise confuses GPD, so it cannot give the correct results. The relative error of impedance measurement after calibration ranges from -4.52 % to 5.98 % with mean value of -0.02 %.

[1]  Antoni Nowakowski,et al.  Advances in electrical impedance methods in medical diagnostics , 2005 .

[2]  M. Anburajan,et al.  Total body composition measurement by using bioelectric impedance analysis and its impact on obesity , 2010, 2010 International Conference on Electronics and Information Engineering.

[3]  Jue Wang,et al.  Design and preliminary evaluation of a portable device for the measurement of bioimpedance spectroscopy , 2006, Physiological measurement.

[4]  Fernando Seoane,et al.  AD5933-based Spectrometer for Electrical Bioimpedance Applications , 2010 .

[5]  Tao Dai,et al.  In Vivo Blood Characterization From Bioimpedance Spectroscopy of Blood Pooling , 2009, IEEE Transactions on Instrumentation and Measurement.

[6]  A. Schonecker,et al.  On the application of special self-calibration algorithm to improve impedance measurement by standard measuring systems , 1999, IMTC/99. Proceedings of the 16th IEEE Instrumentation and Measurement Technology Conference (Cat. No.99CH36309).

[7]  Daniela Matei,et al.  Evaluation of cardiac parameters using electrical impedance plethysmography. , 2012, Revista medico-chirurgicala a Societatii de Medici si Naturalisti din Iasi.

[8]  W. Gulliver,et al.  Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population. , 2005, The American journal of clinical nutrition.

[9]  M. N. Taib,et al.  A non-invasive approach to predict risk in dengue hemorrhagic fever (DHF) using bioelectrical impedance analysis , 2009, 2009 IEEE International Conference on Signal and Image Processing Applications.

[10]  M. Elia,et al.  Bioelectrical impedance analysis--part I: review of principles and methods. , 2004, Clinical nutrition.

[11]  Amar Rouane,et al.  Four electrode embedded bioimpedance measurement system , 2013, 2013 IEEE Faible Tension Faible Consommation.