Three-dimensional virtual histology of human cerebellum by X-ray phase-contrast tomography

Significance The complex cytoarchitecture of human brain tissue is traditionally studied by histology, providing structural information in 2D planes. This can be partly extended to 3D by inspecting many parallel slices, however, at nonisotropic resolution. This work shows that propagation-based X-ray phase-contrast tomography, both at the synchrotron and even at a compact laboratory source, can be used to perform noninvasive 3D virtual histology on unstained paraffin-embedded human cerebellum at isotropic subcellular resolution. The resulting data quality is high enough to visualize and automatically locate ∼106 neurons within the different layers of the cerebellum, providing unprecedented data on its 3D cytoarchitecture and spatial organization. To quantitatively evaluate brain tissue and its corresponding function, knowledge of the 3D cellular distribution is essential. The gold standard to obtain this information is histology, a destructive and labor-intensive technique where the specimen is sliced and examined under a light microscope, providing 3D information at nonisotropic resolution. To overcome the limitations of conventional histology, we use phase-contrast X-ray tomography with optimized optics, reconstruction, and image analysis, both at a dedicated synchrotron radiation endstation, which we have equipped with X-ray waveguide optics for coherence and wavefront filtering, and at a compact laboratory source. As a proof-of-concept demonstration we probe the 3D cytoarchitecture in millimeter-sized punches of unstained human cerebellum embedded in paraffin and show that isotropic subcellular resolution can be reached at both setups throughout the specimen. To enable a quantitative analysis of the reconstructed data, we demonstrate automatic cell segmentation and localization of over 1 million neurons within the cerebellar cortex. This allows for the analysis of the spatial organization and correlation of cells in all dimensions by borrowing concepts from condensed-matter physics, indicating a strong short-range order and local clustering of the cells in the granular layer. By quantification of 3D neuronal “packing,” we can hence shed light on how the human cerebellum accommodates 80% of the total neurons in the brain in only 10% of its volume. In addition, we show that the distribution of neighboring neurons in the granular layer is anisotropic with respect to the Purkinje cell dendrites.

[1]  F. Pfeiffer,et al.  Myoanatomy of the velvet worm leg revealed by laboratory-based nanofocus X-ray source tomography , 2017, Proceedings of the National Academy of Sciences.

[2]  Andre Yaroshenko,et al.  High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography , 2016, Scientific Reports.

[3]  Michael Sprung,et al.  Compound focusing mirror and X-ray waveguide optics for coherent imaging and nano-diffraction. , 2015, Journal of synchrotron radiation.

[4]  S. Torquato,et al.  Spatial Organization and Correlations of Cell Nuclei in Brain Tumors , 2011, PloS one.

[5]  Tim Salditt,et al.  Three-dimensional mouse brain cytoarchitecture revealed by laboratory-based x-ray phase-contrast tomography , 2017, Scientific Reports.

[6]  H M Hertz,et al.  A 9 keV electron-impact liquid-gallium-jet x-ray source. , 2008, The Review of scientific instruments.

[7]  Hans Deyhle,et al.  Extending two-dimensional histology into the third dimension through conventional micro computed tomography , 2016, NeuroImage.

[8]  Manuel Dierick,et al.  Bronnikov-aided correction for x-ray computed tomography. , 2009, Journal of the Optical Society of America. A, Optics, image science, and vision.

[9]  Ziyu Wu,et al.  Low-dose, simple, and fast grating-based X-ray phase-contrast imaging , 2010, Proceedings of the National Academy of Sciences.

[10]  Emmanuel Brun,et al.  High-resolution, low-dose phase contrast X-ray tomography for 3D diagnosis of human breast cancers , 2012, Proceedings of the National Academy of Sciences.

[11]  B. Müller,et al.  Tomographic brain imaging with nucleolar detail and automatic cell counting , 2016, Scientific Reports.

[12]  Tim Salditt,et al.  Phase contrast tomography of the mouse cochlea at microfocus x-ray sources , 2013 .

[13]  Tim Salditt,et al.  X-ray beam compression by tapered waveguides , 2015 .

[14]  X-ray microtomography using correlation of near-field speckles for material characterization , 2015, Proceedings of the National Academy of Sciences.

[15]  Richard A. Ketcham,et al.  New algorithms for ring artifact removal , 2006, SPIE Optics + Photonics.

[16]  Bente Pakkenberg,et al.  Aging of the human cerebellum: A stereological study , 2003, The Journal of comparative neurology.

[17]  F. Pfeiffer,et al.  Trimodal low-dose X-ray tomography , 2012, Proceedings of the National Academy of Sciences.

[18]  Tim Salditt,et al.  Phase-contrast tomography of neuronal tissues: from laboratory- to high resolution synchrotron CT , 2016, Optical Engineering + Applications.

[19]  Tim Salditt,et al.  Laboratory-based x-ray phase-contrast tomography enables 3D virtual histology , 2016, Optical Engineering + Applications.

[20]  Alessandro Olivo,et al.  Phase and absorption retrieval using incoherent X-ray sources , 2012, Proceedings of the National Academy of Sciences.

[21]  K J Batenburg,et al.  Performance improvements for iterative electron tomography reconstruction using graphics processing units (GPUs). , 2011, Journal of structural biology.

[22]  Satyandra K. Gupta,et al.  Algorithms for On-Line Monitoring of Micro Spheres in an Optical Tweezers-Based Assembly Cell , 2007, J. Comput. Inf. Sci. Eng..

[23]  Franz Pfeiffer,et al.  High-resolution tomographic imaging of a human cerebellum: comparison of absorption and grating-based phase contrast , 2010, Journal of The Royal Society Interface.

[24]  Jan Sijbers,et al.  The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography. , 2015, Ultramicroscopy.

[25]  F. Pfeiffer,et al.  Three-dimensional virtual histology enabled through cytoplasm-specific X-ray stain for microscopic and nanoscopic computed tomography , 2018, Proceedings of the National Academy of Sciences.

[26]  P. Cloetens,et al.  Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays , 1999 .

[27]  K. Nugent,et al.  Noninterferometric phase imaging with partially coherent light , 1998 .

[28]  P. Cloetens,et al.  Optimization of phase contrast imaging using hard x rays , 2005 .

[29]  Konrad P. Körding,et al.  Quantifying Mesoscale Neuroanatomy Using X-Ray Microtomography , 2016, eNeuro.